Page 2 - serviced. Keep burner and control compartment clean.; TABLE of CONTENTS; PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE
2 W415-0319 / E / 01.17.07 HoodLouvre BracketHinge ScreenLouvre Installation & RemovalHeat Shield Stand Off RemovalLogo Placement 16-17 OPTIONS Patented Catalytic Glass DoorBlower Installation 18-19 OPERATION / MAINTENANCE Operating InstructionsMaintenanceCatalytic Tile MaintenanceOxygen Depleti...
Page 3 - NAPOLEON GAS FIREPLACE PRESIDENT'S LIFETIME LIMITED WARRANTY; CONDITIONS AND LIMITATIONS; causing property damage, personal injury or death.; FOR YOUR SAFETY; • Immediately call your gas supplier from a; combustion and ventilation air must be provided.
3 W415-0319 / E / 01.17.07 NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their wor...
Page 4 - OXYGEN DEPLETION; and is designed to turn off the heater if; Use only accessories designed for and; to conform with; American Nation Standards Institute Inc.; or; National Fire Protection Association Inc.; Batterymarch Park; Get fresh air
4 W415-0319 / E / 01.17.07 This fireplace may be installed in an aftermarket per-manently located, manufactured (mobile) home, wherenot prohibited by local codes.This fireplace is only for use with the type of gas indi-cated on the rating plate. This fireplace is not convert-ible for use with other ...
Page 5 - If additional fresh air; INSTALLATION; COMBUSTION AND VENTILATION
5 W415-0319 / E / 01.17.07 This heater shall not be installed in a confinedspace or unusually tight construction unless pro-visions are provided for adequate combustion andventilation air. In order to avoid the possibility of exposed insu- lation or vapour barrier coming in contact with the fireplac...
Page 6 - FIGURE 3; EXAMPLE 1; GAS INSTALLATION
6 W415-0319 / E / 01.17.07 50 If in this example a solid door separates Room 1 fromRoom 2, the volume of Room 2 could not be used. In thiscase the maximum BTU/h would be: Maximum BTU/h: 800 x 1000 = 16,000 BTU/h This would be considered a confined space since it cannot support the 30,000BTU/h input ...
Page 7 - PENINSULA
7 W415-0319 / E / 01.17.07 FIGURES 4 a-d PENINSULA OPEN-END SEE-THRU 4-SIDED
Page 8 - In order to avoid the possibility of exposed insula-; FIGURE 5; FIGURE 8; The top extension may be removed if non-combustible; PENINSULA INSTALLATION PROCEDURE; FRAMING
8 W415-0319 / E / 01.17.07 Note: In order to avoid the possibility of exposed insula- tion or vapour barrier coming in contact with thefireplace body, it is recommended that the walls of thefireplace enclosure be “finished” (ie: drywall/sheetrock),as you would finish any other outside wall of a home...
Page 9 - RETAINER; DRYWALL; BRICK PANEL INSTALLATION
9 W415-0319 / E / 01.17.07 Combustible materials may be installed flush with the frontof the fireplace but must not cover any of the black face-areas of the fireplace. Non-combustible material (brick,stone or ceramic tile) may protrude in these areas.It is not necessary to install a hearth extension...
Page 10 - OPEN-END INSTALLATION PROCEDURE
10 W415-0319 / E / 01.17.07 FIGURE 14 Note: In order to avoid the possibility of exposed insula- tion or vapour barrier coming in contact with thefireplace body, it is recommended that the walls of thefireplace enclosure be “finished” (ie: drywall/sheetrock),as you would finish any other outside wal...
Page 11 - SEE-THROUGH INSTALLATION PROCEDURE; FACING
11 W415-0319 / E / 01.17.07 Install the base panels as illustrated in steps 1-4 on page9. Both side panels sit under the bracket tab . Holding the side panel in position, bend down the tab to secure. [DE- TAIL 6]. DRYWALL DRYWALL 4" MIN FIGURE 17 Note: In order to avoid the possibility of expose...
Page 12 - ISLAND INSTALLATION PROCEDURE
12 W415-0319 / E / 01.17.07 Combustible materials may be installed flush with the frontof the fireplace but must not cover any of the black face-areas of the fireplace. Non-combustible material (brick,stone or ceramic tile) may protrude in these areas.It is not necessary to install a hearth extensio...
Page 13 - PHAZER; back left; LOCATING PINS; FINISHING; LOG PLACEMENT
13 W415-0319 / E / 01.17.07 PHAZER TM logs, glowing and charcoal embers, exclusive to Napoleon fireplaces, provide a unique and realistic glow-ing effect that is different in every installation. Take the timeto carefully position the embers for a maximum glowingeffect. Figures 21 A - H. 1 . Place lo...
Page 14 - Fine dust found in bottom of bag not to be used.; GLOWING EMBERS; CARRY OVER PORTS; HOOD
14 W415-0319 / E / 01.17.07 The curtain mesh must be kept fully closed during opera-tion to help prevent accidental burns from occurring. The heater mustnot be used whent h e h o o d i s r e -moved. Hook the hood over the lip ofthe curtain supportplate. Combustible mantle clearance can vary accordin...
Page 15 - L36 LOUVRE INSTALLATION; LOGO PLACEMENT; HEA
15 W415-0319 / E / 01.17.07 L36 LOUVRE INSTALLATION FIGURE 32 a-c HOOD Attach the hood by pressing thetop flange into the clips alongthe top of the louvre opening.Secure using a screw throughthe centre slot. LOWER LOUVRES Insert the hinge clips into theslots located at the bottom leftand right corne...
Page 16 - designed for use with; The mesh must be removed if the catalytic door is used.; The heater must not be used when the hood is removed.; OPTIONS; DOOR INSTALLATION; DOOR; DOOR OPENING AND CLOSING
16 W415-0319 / E / 01.17.07 Notes:Ornamental insets can not be used in conjunctionwith the catalytic doorWhen using a catalytic door, glassed doors mustbe used on all other side or end openings. This unique patented catalytic system was designed toprovide unparalleled safety and peace of mind. The t...
Page 17 - a n d m u s t b e e l e c t r i c a l l y c o n n e c t e d a n d; in the United States.; THIS BLOWER IS NOT RECOMMENDED FOR THE 4 SIDED INSTALLATION.; OPTIONAL BLOWER INSTALLATION
17 W415-0319 / E / 01.17.07 Remove the thermodisc bracket from the top of the firebox.Remove the thermodisc from the bracket supplied in theblower kit and install the thermodisc into the fireplacebracket. Then replace the bracket in the location it wasremoved.Connect the two ends of the unattached w...
Page 18 - IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLO-; OXYGEN DEPLETION SENSOR; If heater shuts off, do not relight until you provide; FF; OPERATION / MAINTENANCE; FOR YOUR SAFETY READ BEFORE LIGHTING:
18 W415-0319 / E / 01.17.07 When lighting and re-lighting, the gas knob cannot beturned from pilot to off unless the knob is depressed. 1. STOP! Read the above safety information on this la- bel. 2. Set the thermostat to lowest setting. 3. Turn off all electric power to the fireplace. 4. Open the co...
Page 19 - AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE; CORRECT PILOT; AIR SHUTTER OPENINGS; TURN OFF THE GAS AND ELECTRICAL POWER; at least once a year; Catalytic output must be checked annually at the; NG; CATALYTIC TILE; VENTURI; MAINTENANCE
19 W415-0319 / E / 01.17.07 THIS PROCEDURE MUST BE PERFORMED BY A QUALIFIED SERVICE PERSON! Inspect the pilot for any visible contamination or debris(usually lint, pet hair, spider webs, carpet fibre, etc.) andremove.Disconnect the pilot from the pilot tubing line. Using a 7 / 16 ” wrench, remove th...
Page 20 - REPLACEMENTS; COMPONENTS COMMON TO ALL UNITS; COMPONENTS UNIQUE TO PENINSULA UNIT; BURNER COMPONENTS; COMPONENTS UNIQUE TO ISLAND UNIT; ACCESSORIES
20 W415-0319 / E / 01.17.07 Contact your dealer for questions concerning prices andavailability of replacement parts. Normally all parts can beordered through your Napoleon dealer or distributor. # PART No. DESCRIPTION 1* W361-0016 GLOWING EMBERS 2* W550-0001 CHARCOAL EMBERS 3* GD660 STANDARD WALL S...
Page 22 - TROUBLE SHOOTING GUIDE; SYMPTOM
22 W415-0319 / E / 01.17.07 Main burner goesout; pilot stays on. P i l o t f l a m e i s n o t l a r g eenough or not engulfing thethermopile - service or replace Oxygen Depletion Sensor System- correct piping and/or regulator to provide correct pressure Thermopile shorting - clean thermopile connec...
Page 23 - Not enough combustion air.; - ensure air shutter opening is free of lint or other obstructions.
23 W415-0319 / E / 01.17.07 W h i t e / g r e y f i l mforms on the glassof the optional cata-lytic door. Sulphur from fuel is beingdeposited on glass, logs orcombustion chamber sur-faces. - clean the glass with a recommended gas fireplace glass cleaner.DO NOT CLEAN GLASS WHEN HOT.If deposits are no...
Page 24 - This fireplace must be serviced annually depending on usage.
24 W415-0319 / E / 01.17.07 W olf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Dealer Name