Napoleon Fireplace - Manual

Napoleon Fireplace

Napoleon Fireplace – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
Page: / 22

Table of Contents:

  • Page 2 – TABLE of CONTENTS; OPERATING INSTRUCTIONS; WARNING
  • Page 4 – GENERAL INSTRUCTIONS; RATES AND EFFICIENCIES; NATURAL GAS
  • Page 5 – CARE OF GLASS AND PLATED PARTS; VENTING; VENTING LENGTHS AND AIR TERMINAL LOCATIONS; Use only Wolf Steel Ltd.; GD178 wall terminal kit
  • Page 6 – VENT INSTALLATIONS; HORIZONTAL VENT SECTIONS; Use
  • Page 7 – TYPICAL VENT INSTALLATIONS - HORIZONTAL TERMINATION; FIGURE 2a; FIGURE 2b; See graph to determine the required vertical rise
  • Page 8 – TYPICAL VENT INSTALLATIONS - VERTICAL TERMINATION; FIGURE 3a; FIGURE 3b
  • Page 9 – MINIMUM AIR TERNMINAL LOCATION CLEARANCES; D E; FIGURE 4
  • Page 10 – INSTALLATION / FRAMING; WALL AND CEILING PROTECTION; FIGURE 5; Do not; VERTICAL INSTALLATION; FIGURE 6; FIRESTOP; FIGURE 7
  • Page 11 – Use only approved; FIGURE 9; SPACERS; NOTE: If using pipe clamps to connect vent; VERTICAL AIR TERMINAL INSTALLATION
  • Page 12 – FIREPLACE VENT CONNECTION; Conversion Kits
  • Page 13 – ELECTRICAL CONNECTION; RISK OF ELECTRIC SHOCK!; replace when; Do not use open; GAS INSTALLATION
  • Page 14 – NOTE: Finished opening is smaller than the framed opening.
  • Page 15 – CLEARANCES TO COMBUSTIBLES; Minimum clearance to combustible construction from; replace. Next gripping the sides of the door lift; DOOR REMOVAL; FINISHING; GLASS REMOVAL; Having removed the door, lay on a smooth; WITHOUT
  • Page 16 – FRAME/FRONT INSTALLATION
  • Page 17 – SW; TL; CLIPS X5; ACCENT GLASS INSTALLATION; BURNER
  • Page 18 – FOR YOUR SAFETY READ BEFORE LIGHTING:; TO TURN OFF GAS; RATING PLATE
  • Page 19 – ADJUSTMENTS; GAS PRESSURE ADJUSTMENT; AIR SHUTTER OPENINGS; TURN OFF THE GAS AND ELECTRICAL POWER BEFORE; MAINTENANCE; FLAME CHARACTERISTICS
  • Page 20 – PART NO. DESCRIPTION; REPLACEMENTS; REPLACEMENT PARTS
  • Page 21 – TROUBLE SHOOTING GUIDE; SYMPTOM
  • Page 22 – Fireplace Service History; This fireplace must be serviced annually depending on usage
Loading the manual

1

W415-0619 / B / 03.03.08

INSTALLATION

AND

OPERATION INSTRUCTIONS

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada

(705)721-1212

fax(705)722-6031

www.napoleonfireplaces.com

[email protected]

CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.22, ANSI Z21.50 FOR VENTED GAS FIREPLACE.

GT8N

NATURAL GAS

GT8P

PROPANE

- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use

any phone in your building.

Immediately call your gas supplier from a

neighbour’s phone. Follow the gas supplier’s

instructions.

If you cannot reach your gas supplier, call the

fire department.

- Installation and service must be performed by a
qualified installer, service agency or the supplier.

SAFETY INFORMATION

Certified for Canadian and United States using ANSI/CSA Methods.

If the information in these instructions are not
followed exactly, a fire or explosion may result
causing property damage, personal injury or loss
of life.

!

WARNING

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.

CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

$10.00

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TABLE of CONTENTS; OPERATING INSTRUCTIONS; WARNING

2 W415-0619 / B / 03.03.08 PG 2-5 INTRODUCTION Warranty General Instructions General Information Care of Glass and Plated Parts Dimensions 5-10 VENTING Venting Lengths and Air Terminal Locations Vent Installations Typical Vent Installations - Horizontal Termination Typical Vent Installations - Verti...

Page 4 - GENERAL INSTRUCTIONS; RATES AND EFFICIENCIES; NATURAL GAS

4 W415-0619 / B / 03.03.08 THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. Installation practices vary from region to region and it is important to know the speci fi cs that apply to your area, for example: in Massachusetts State: • The fi re...

Page 5 - CARE OF GLASS AND PLATED PARTS; VENTING; VENTING LENGTHS AND AIR TERMINAL LOCATIONS; Use only Wolf Steel Ltd.; GD178 wall terminal kit

5 W415-0619 / B / 03.03.08 3 / 4 43 GAS LINE ACCESS ELECTRICAL ACCESS FIGURES 1a-c The glass is 3/16” ceramic glass, available from your Napoleon® / Wolf Steel Ltd. dealer. Clean the glass after the fi rst 10 hours of operation with a recommended gas fi replace glass cleaner. Thereafter clean as req...