Page 2 - BGD42 TABLE of CONTENTS; PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE; WARNING
2 W415-0381 / H / 12.07.07 20-22 FINISHING Door, Louvre & Panel Removal & Installation Grate Installation Log Placement / Glowing Embers Vermiculite Charcoal Embers Charcoal Lumps 22 OPTIONAL BLOWER INSTALLATION 22-23 OPTIONAL FAN INSTALLATION / GD36 THERMOSTATIC SENSOR CON- TROL 23 OPERATIO...
Page 4 - GENERAL INSTRUCTIONS
4 W415-0381 / H / 12.07.07 THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. In absence of local codes, install the BGD42 to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes. Installation practice...
Page 5 - FIGURE 1; INSTALLATION OVERVIEW; FIGURE 2
5 W415-0381 / H / 12.07.07 FIGURE 1 INSTALLATION OVERVIEW FIGURE 2
Page 6 - VENTING; VENTING LENGTHS
6 W415-0381 / H / 12.07.07 A terminal shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings. Local codes or regulations may require different clearances. Do not allow the inside liner to bunch up on horizontal o...
Page 7 - MINIMUM AIR TERMINAL LOCATION CLEARANCES; FIGURE 3
7 W415-0381 / H / 12.07.07 MINIMUM AIR TERMINAL LOCATION CLEARANCES 32 32 32 32 32 32 4 U s i n g a s o f f i t h e a t s h i e l d ( W 5 8 5 - 0 0 9 6 ) , o r e q u i v a l e n t , t h e d i s t a n c e m a y b e r e d u c e d t o a m i n i m u m o f 1 8 ” . I t i s r e c o m m e n d e d t o m a x ...
Page 8 - FIGURE 5; TYPICAL VENT INSTALLATIONS; PERISCOPE TERMINATION; SPECIAL VENT INSTALLATIONS
8 W415-0381 / H / 12.07.07 Use the GD401 periscope kit to locate the air termination above grade. The periscope must be installed so that when fi nal grading is completed, the bottom air slot is located a minimum of 12" above grade. FIGURES 4 a-b FIGURE 5 TYPICAL VENT INSTALLATIONS NOTE: When ter...
Page 9 - VENTING APPLICATION FLOW CHART
9 W415-0381 / H / 12.07.07 VERTICAL TERMINATION HORIZONTAL TERMINATION vertical rise is equal to or greater t h a n t h e horizontal runhorizontal run + verti-c a l r i s e t o m a x i m u m of 40 feet vertical rise is equal to or greater t h a n t h e horizontal run h o r i z o n t a l run + verti-...
Page 10 - HORIZONTAL TERMINATION; REQUIRED
10 W415-0381 / H / 12.07.07 ELBOW VENT LENGTH VALUES DEFINITIONS HORIZONTAL TERMINATION REQUIRED V E R T I C A L R I S E I N FEET (V T ) CALCULATED HORIZONTAL VENT RUN PLUS OFFSETS IN FEET (H T ) FIGURE6 45º FIGURE 7 90° H 1 H 2 when (H T ) < (V T ) Simple venting confi guration (only one 45º and ...
Page 11 - FIGURE 8; FIGURE 9
11 W415-0381 / H / 12.07.07 V 1 HORIZONTAL TERMINATION See graph to determine the re-q u i r e d v e r t i c a l r i s e V T f o r t h e required horizontal run H T . For vent confi gurations requiring more than one 45º and 90° elbow the following formulas apply: Formula 1: H T < 4.2 V T Formula 2...
Page 12 - VERTICAL TERMINATION
12 W415-0381 / H / 12.07.07 90° 90° V 1 H 1 H 2 V 2 45° 90° 45° VERTICAL TERMINATION Example 3: V 1 = 5 ft V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 = 3 ft H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03(one 45º elbow + three 90º elbows - 135º) = .03(45+90+90+90-135)=5.4 H T = H R +...
Page 13 - unacceptable
13 W415-0381 / H / 12.07.07 H 1 VERTICAL TERMINATION For vent confi gurations requiring more than one 45º and one 90° elbow , the following formulas apply: For mula 1: H T < 3V T For mula 2: H T + V T < 40 feet when (H T ) > (V T ) Simple venting confi gurations See graph to determine the req...
Page 14 - HORIZONTAL INSTALLATION; INSTALLATION; ADJUSTABLE FIRESTOP INSTALLATION; VENT PIPE
14 W415-0381 / H / 12.07.07 1. Determine the air terminal location, cut and frame 10 3/4" square openings in the ceiling and the roof to provide the minimum 1" clear-ance between the vent pipe and any combustible material. Try to center the vent pipe location midway between two joist to prev...
Page 15 - USING FLEXIBLE VENT COMPONENTS
15 W415-0381 / H / 12.07.07 DO NOT CLAMP THE FLEXIBLE LINER FIGURE 24b 1. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an al-ternate method suitable to the authority having jurisdictio...
Page 16 - FIREPLACE VENT CONNECTION; USING RIGID VENT COMPONENTS
16 W415-0381 / H / 12.07.07 FIGURE 25 5. Remove nails from the shingles, above and to the sides of the chimney. Place the fl ashing over the air terminal connector leaving a min. 3/4” of the air terminal connector showing above the top of the fl ashing. Slide the fl ashing underneath the sides and uppe...
Page 17 - VERTICAL VENTING INSTALLATION; OPTIONAL WALL SWITCH
17 W415-0381 / H / 12.07.07 1. Move the fi replace into position. 2. Fasten the roof support to the roof using the screws provided. FIGURE 21. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdi...
Page 18 - MOBILE HOME INSTALLATION
18 W415-0381 / H / 12.07.07 FIGURE 33 This Mobile/Manufactured Home Listed appliance comes factory equipped with a means to secure the unit. The fi replace is equipped with two 1/4" diameter holes located in the front left and right corners of the base. For mobile home installations, the fi replac...
Page 19 - NAILING TAB INSTALLATION
19 W415-0381 / H / 12.07.07 FIGURE 34 FIGURES 36a-c TOP SLOT FINISHING MATERIAL CORNER POST NAILING TAB A B C CENTRE HOLE NAILING TAB 1) Attach the nailing tabs to the corner posts using the 2 sheet metal screws supplied. Secure through the centre of the top and bottom slots in the nailing tab and t...
Page 20 - L42 LOUVRE INSTALLATION; FINISHING; GLASS/DOOR REPLACEMENT
20 W415-0381 / H / 12.07.07 MINIMUM MANTEL AND ENCLOSURE CLEARANCES FIGURES 37a FIGURES 37b Combustible mantel clearance can vary according to the mantel depth. FIGURE 36. Use the graph to help evaluate the clearance needed. Curtains, above the fi replace, must not be positioned lower than the 5"...
Page 21 - LOGO; LOGO PLACEMENT; GRATE INSTALLATION; GLOWING EMBERS
21 W415-0381 / H / 12.07.07 Remove the backing of the logo supplied and place on the glass view-ing door, as indicated. FIGURE 40 LOGO ½" ½" LOGO PLACEMENT PORCELAIN REFLECTIVE PANELS 1. Remove the upper louvres, and open the glass door. Remove the logs. 2. Remove the two securing screws loc...
Page 22 - CHARCOAL EMBERS; OPTIONAL BLOWER INSTALLATION; OPTIONAL FAN INSTALLATION
22 W415-0381 / H / 12.07.07 FIGURE 44 FIGURE 48 FIGURE 49 FIGURE 45 FIGURE 50 INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must be electrically con-n e c t e d a n d g r o u n d e d i n a c - cordance with local codes. In the absence of local codes, use the current CSA C22.1 C ANADIAN ELECTR...
Page 23 - GD36 THERMOSTATIC SENSOR CONTROL; OPERATION / MAINTENANCE; OPERATING INSTRUCTIONS; MAINTENANCE
23 W415-0381 / H / 12.07.07 Unplug the power cord from the receptacle. Connect all wires as shown. Attach and secure the sen-sor assembly bracket to the securing stud located n e x t t o t h e r e c e p t a c l e /junction box at the bottom left of the unit using the lock washer and wing nut. Ensure...
Page 24 - AIR; ADJUSTMENTS; PILOT BURNER ADJUSTMENT; FLAME CHARACTERISTICS
24 W415-0381 / H / 12.07.07 FIGURE 57 Closing the air shutter will cause a more yellow fl ame, but can lead to carboning. Opening the air shutter will cause a more blue fl ame, but can cause fl ame lifting from the burner ports. The fl ame may not appear yellow immediately; allow 15 to 30 minutes for th...
Page 25 - REPLACEMENT PARTS; REPLACEMENTS; FLEXIBLE VENT KITS; ACCESSORIES; ROOF TERMINAL KITS
25 W415-0381 / H / 12.07.07 # PART NO. DESCRIPTION 1 W357-0001 PIEZO IGNITER 2 W680-0004 THERMOPILE 3 W680-0005 THERMOCOUPLE** 4 W010-0800 NATURAL GAS PILOT ASSEMBLY 4 W010-0801 PROPANE GAS PILOT ASSEMBLY 5 W455-0069 NATURAL GAS PILOT INJECTOR 5 W455-0067 PROPANE GAS PILOT INJECTOR 6 W725-0025 NATUR...
Page 27 - TROUBLE SHOOTING GUIDE; SYMPTOM
27 W415-0381 / H / 12.07.07 Pilot will not light. - check if pilot can be lit by a match- check that the wire is connected to the push button igniter.- check if the push button igniter needs tightening.- replace the wire if the wire insulation is broken or frayed.- replace the electrode if the ceram...