Page 2 - TABLE of CONTENTS; WARNING
2 W415-0299 / J / 04.14.08 Pg 3-5 INTRODUCTION Warranty General Instructions General Information Care of Glass & Plated Parts Dimensions 6-13 VENTING Vent Lengths Minimum Air Terminal Location Clearances Venting Application Flow Chart Typical Minimum and Maximum Vent Lengths Special Vent Install...
Page 4 - GENERAL INSTRUCTIONS; INTRODUCTION; CARE OF GLASS, AND PLATED PARTS
4 W415-0299 / J / 04.14.08 THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. Installa- tion practices vary from region to region and it is important to know the specifi cs that apply to your area, For example: in Massachusetts State:• The fi repl...
Page 5 - DIMENSIONS; PENINSULA; FIGURE 1a
5 W415-0299 / J / 04.14.08 DIMENSIONS SEE-THRU PENINSULA OPEN-END FIGURE 1a FIGURE 1b FIGURE 1c
Page 6 - VENTING; VENTING LENGTHS
6 W415-0299 / J / 04.14.08 Use only Wolf Steel or Simpson Dura-Vent Model DV-GS, Selkirk Direct Temp or American Metal Amerivent venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, and air terminal loca-tions for either system are set out in this man...
Page 7 - MINIMUM AIR TERMINAL LOCATION CLEARANCES; FIGURE 2
7 W415-0299 / J / 04.14.08 MINIMUM AIR TERMINAL LOCATION CLEARANCES FIGURE 2
Page 8 - VENTING APPLICATION FLOWCHART; VERTICAL
8 W415-0299 / J / 04.14.08 VENTING APPLICATION FLOWCHART VERTICAL TERMINATION HORIZONTAL TERMINATION V e r t i c a l rise is equal to or great-er than the horizontal run H o r i zo n t a l run + verti-c a l r i s e t o m a x i m u m of 40 feet V e r t i c a l rise is equal to or great-er than the ho...
Page 9 - TYPICAL MINIMUM AND MAXIMUM VENT LENGTHS; SPECIAL VENT INSTALLATION; PERISCOPE TERMINATION
9 W415-0299 / J / 04.14.08 Use the GD401 periscope kit to locate the air termination above grade. The periscope must be installed so that when fi nal grading is completed, the bottom air slot is located a minimum of 12" above grade. When venting, the horizontal run must be kept to a maximum of 20...
Page 10 - FIGURE 5; DEFINITIONS; HORIZONTAL TERMINATION
10 W415-0299 / J / 04.14.08 REQUIRED V E R T I C A L R I S E I N FEET (V T ) CALCULATED HORIZONTAL VENT RUN PLUS OFFSETS IN FEET (H T ) FIGURE 5 45º FIGURE 6 90° H 1 H 2 When (H T ) < (V T ) Simple venting confi guration (only one 45º and 90° elbow) for the following symbols used in the venting ca...
Page 11 - FIGURE 7; FIGURE 8
11 W415-0299 / J / 04.14.08 See graph to determine the required vertical rise V T for the required hori- zontal run H T . For vent confi gurations requiring more than one 45º and 90° elbow the following formulas apply: Formula 1: H T < 4.2 V T Formula 2: H T + V T < 24.75 feet FIGURE 7 REQUIRED...
Page 12 - FIGURE 9; VERTICAL TERMINATION
12 W415-0299 / J / 04.14.08 Example 3: V 1 = 5 ft V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 = 3 ft H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03(one 45º elbow + three 90º elbows - 135º) = .03(45+90+90+90-135)=5.4 H T = H R + H O = 5.5 + 5.4 = 10.9 ft H T + V T = 10.9 + 15 = 25.9 f...
Page 14 - PENINSULA INSTALLATION PROCEDURE
14 W415-0299 / J / 04.14.08 Refer to pages 6-13. All venting must have a minimum clear-ance of 2" to combustible material on the top and 1" to the sides and bottom. See Page 18 for additional framing dimensions.NOTE: In order to avoid the possibility of exposed insula- tion or vapor barrier ...
Page 15 - DETAIL 5; BRICK PANEL INSTALLATION
15 W415-0299 / J / 04.14.08 Combustible materials may be installed fl ush with the front of the fi replace but must not cover any of the black face-areas of the fi replace. Non-combustible material (brick, stone or ceramic tile) may protrude in these areas. It is not necessary to install a hearth exten...
Page 16 - DETAIL 6; OPEN-END INSTALLATION PROCEDURE
16 W415-0299 / J / 04.14.08 Refer to pages 6-13. All venting must have a minimum clear-ance of 2" to combustible material on the top and 1" on the sides and bottom. See Page 18 for additional framing dimensions.NOTE: In order to avoid the possibility of exposed insula- tion or vapor barrier ...
Page 17 - SEE-THROUGH INSTALLATION PROCEDURE
17 W415-0299 / J / 04.14.08 Refer to pages 6-13. All venting must have a minimum clear-ance of 2" to combustible material on the top and 1" to the sides and bottom. See Page 18 for additional framing dimensions.NOTE: In order to avoid the possibility of exposed insula- tion or vapor barrier ...
Page 18 - MINIMUM VENT FRAMING DIMENSIONS
18 W415-0299 / J / 04.14.08 There must be a minimum of 2" clearance to combustible ma-terial on the top and 2" to the sides and bottom when framing around all venting options. See pages 10-13. FIGURE 27a FIGURE 27b Horizontal Vent Off Fireplace Vertical Vent Off Fireplace A = 43" using fl...
Page 19 - HORIZONTAL INSTALLATION
19 W415-0299 / J / 04.14.08 FIGURE 33 FIGURE 31 INSTALLATION WALL AND CEILING PROTECTION HORIZONTAL INSTALLATION VERTICAL INSTALLATION FIGURE 32 FIGURE 29 Apply a bead of caulking all around and place the fi restop top, so that the vent shield covers the top of the vent within the opening. Place the ...
Page 20 - USING FLEXIBLE VENT COMPONENTS
20 W415-0299 / J / 04.14.08 For safe and proper operation of the fi replace, follow the vent-ing instructions exactly. Eight (8") inches is the minimum bend radius allowed for the 8" diameter fl exible liner. 1. Stretch the 5" diameter fl ex pipe to the required length tak- ing into account...
Page 21 - FIREPLACE VENT CONNECTION
21 W415-0299 / J / 04.14.08 FIGURE 41 1. Install the 5" diameter fl ex pipe to the fi replace. Secure with 3 screws and fl at washers. Seal the joint and screw holes using h i g h t e m p s e a l a n t (not supplied) or Red RT V S i l i c o n e m a y also be used in this location. 2. Install the 8&...
Page 22 - FINISHING; MINIMUM MANTEL AND ENCLO-; OPTIONAL WALL SWITCH INSTALLATION
22 W415-0299 / J / 04.14.08 Combustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the clearance needed. The three-sided top extension piece may be removed if non-combustible framing is faced with a non-combustible material. * SEE FIGURE 44 . FINISHING MI...
Page 23 - LOG PLACEMENT
23 W415-0299 / J / 04.14.08 PHAZER TM logs, glowing and charcoal embers, exclusive to Wolf Steel Ltd. fi replaces, provide a unique and realistic glowing effect that is different in every installation. Take the time to carefully position the embers for a maximum glowing effect. Figures 49 A - H. 1 . ...
Page 24 - L36 LOUVRE INSTALLATION; GLOWING EMBERS; LOGO; LOGO PLACEMENT
24 W415-0299 / J / 04.14.08 L36 LOUVRE INSTALLATION FIGURE 52 a-c HOOD Attach the hood by pressing the top fl ange into the clips along the top of the louvre opening. Secure using a screw through the centre slot. LOWER LOUVRES Insert the hinge clips into the slots located at the bottom left and right...
Page 25 - END DOOR INSTALLATION
25 W415-0299 / J / 04.14.08 E n s u r e t h a t t h e door is pr oper l y clipped onto the s t e e l l i p t o p r e -vent overheating, g l a s s b r e a k a g e and / or discolora-tion of the upper trim. To i n s t a l l t h e d o o r ( s ) , hook it over the steel lip located above the door openin...
Page 26 - OPTIONAL BLOWER INSTALLATION
26 W415-0299 / J / 04.14.08 R e m o v e t h e " Z " s h a p e d mounting bracket secured to the burner, by the pilot. Remove the thermodisc from the bracket supplied in the blower kit and attach to the mounting bracket. Attach the connectors from the black and white wires to the ther-modisc....
Page 27 - OPERATION / MAINTENANCE; MAINTENANCE
27 W415-0299 / J / 04.14.08 • Turn off all gas to the fi replace.• Open windows.• Do not try to light any appliance.• Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbour's phone. Follow the gas sup-plier's instructions. • If y...
Page 28 - ADJUSTMENTS; PILOT BURNER ADJUSTMENT; FLAME CHARACTERISTICS
28 W415-0299 / J / 04.14.08 Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow. Natural gas models have air shutters set at 1/4 (.250") inch open. Propane gas models have air shutters set at 7/16 (.437) inch open. Closing the air shutter ...
Page 29 - REPLACEMENTS
29 W415-0299 / J / 04.14.08 # PART No. DESCRIPTION 1* W361-0016 GLOWING EMBERS 2* W550-0001 CHARCOAL EMBERS 3* W562-0009 DOOR GASKET (100") 4 W010-0454 GLASS W/ GASKET 5 W010-1778 FIRESTOP 6* W385-0245 NAPOLEON ® LOGO 8 GL-657 BGD40 LOGSET 9 W135-0284 LOG#1 10 W135-0285 LOG#2 11 W135-0286 LOG#3 ...
Page 31 - ACCESSORIES
31 W415-0299 / J / 04.14.08 # PART No. DESCRIPTION 1 W690-0001 MILLIVOLT THERMOSTAT 2 GD501 HEAT GUARD 3* W573-0007 HI-TEMP SEALANT 4* W010-0370 WALL SUPPORT ASSEMBLY 5 GZ-550-1KT BLOWER KIT 6* W175-0170 DURA-VENT ZERO CLEARANCE ADAPTOR 7* W500-0033 VARIABLE SPEED SWITCH WALL MOUNTING PLATE 8* W660-...
Page 32 - TROUBLE SHOOTING GUIDE; SYMPTOM
32 W415-0299 / J / 04.14.08 TROUBLE SHOOTING GUIDE B EFORE ATTEMPTING TO TROUBLESHOOT , PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR OPEN . SYMPTOM PROBLEM TEST SOLUTION Main burner fl ame is a blue, lazy, transparent fl ame. Blockage in vent. - Remove blockage...
Page 34 - This fireplace must be serviced annually depending on usage.
34 W415-0299 / J / 04.14.08 W o lf Steel Fir e place Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T e chnician Name Service Performed S pecial Concerns Dealer Name
Page 35 - NOTES