Page 2 - Introduction of Maintenance Tools; Foreword
1 1.1 Introduction of Maintenance Tools The Maintenance Tools are comprised of the On-Line Monitor and the Off-Line Monitor . The following two connection methods are available in the Online Monitoring. (1) Monitoring by connecting the maintenance tool to MN converter (CMS-MNF) via RS-232C. (2) Moni...
Page 5 - This manual refers to Windows; Available space 5 GB or more *2; *2 About Hard Disk Space
4 1.2 Required Operating Environment This manual refers to Windows ® 2000 as Windows 2000, and Windows ® XP as Windows XP. Trademarks MS, Microsoft, Microsoft logo, and Windows are registered trademarks and trade names of Microsoft Corporation. Each company may use as registered trademarks and trade...
Page 6 - There are two Maintenance Tool setup methods:; To set up Maintenance Tools, follow the 3 steps below.
5 1.3 Installation There are two Maintenance Tool setup methods: Method 1) New setup.(See Section 1.3.1) Method 2) Upgrading with existing setup.(See Section 1.3.2) 1.3.1 Setting Up the Maintenance Tools (New setup) To set up Maintenance Tools, follow the 3 steps below. Step 1) Setting up of MSDE St...
Page 7 - Maintenance Tools
6 Step 3) Setting up the Maintenance Tools Set up the application of this Maintenance Tools . Please read the guide shown on the screen carefully to proceed the setting up. (1) Starting the setup program 1) Start setup.exe. Execute “setup.exe” located in SetUp ¥3_MNTTOOL folder of CD-ROM. Double cli...
Page 10 - Starting and Ending the Application
9 1.4 Starting and Ending the Application 1.4.1 Starting the Maintenance Tool (1) Connect the computer and G-50A(MN Converter) and air conditioner. (2) Click on “ Start ”, and then click on ” Programs ”. (3) Click on “ Maintenance Tool for Windows2000 & XP ” in the “ Maintenance Tool ” folder. (...
Page 11 - (2) Next the screen to set remote connection will appear. In
10 1.4.2 Starting the On-Line Monitor(MN Converter connection) 1.4.2.1 In case for local connection This will be used when online monitoring is adapted to air conditioning system by connecting the maintenance tool and MN Converter locally. The maintenance tool, MN Converter and air conditioning syst...
Page 13 - Customer Selection Screen; will appear. This screen; Connection Status Indication Screen
12 (4) Initiating the remote connection To initiate the remote connection, click on the remote setting screen. The Customer Selection Screen will appear. This screen connects to the on-site remote modem. (a) When the addressee has already been registered, select the customer name to be connected in ...
Page 15 - Remote Monitor screen
14 1.4.3.2 In case for remote connection (Dialup) In the case when on line monitoring is applied to local air conditioning system (with G-50 installed) from the maintenance tool in the remote place via public telephone circuit. * When utilizing Remote connection (Dialup),please prepare MODEM and DIA...
Page 18 - : Accessing by dialup connection to G-50A via public network.; Modem
17 1.4.4 Starting the Off-Line Monitor When offline analysis is adapted to the data collected under ONLINE MODE. (1) Clicking "Offline Analyze" on the selection screen of Monitor mode. Last click " ." 1.4.5 Using the Wide area access mode Under the "Wide area access mode," th...
Page 23 - Terms for Each Section
22 2.1 Design of Screen The design of the screen is shown below. - Title Bar Displays the title of the screen. - Menu Bar Displays the functions that can be performed using the current screen. Click on an item and a sub-menu or message screen will appear, as shown in the illustration. If a sub-menu ...
Page 24 - On-Line Monitor Operating Method
23 3.1 On-Line Monitor Screen Transfer 3 On-Line Monitor Operating Method Title Screen Main Screen Malfunction Log Operation Control Connecting Information Operation Monitor Optional Setting
Page 25 - Address Search Method; Select The Address Searching Method Screen
24 3.2 Function Chart Connecting Information ----------------------- [Refer to 3.6] This allows monitoring of the indoor units connected to the outdoor unit and of the interlock units and the operation group SC connected to indoor units. Operation Monitor ------------------------------- [Refer to 3....
Page 28 - (4) If the wrong function selection button is clicked, click; Connecting Information; (1) Click on on the
27 3.5 Function Selection Operations (1) First, click on the desired [ Function Selection Button ]. (2) Next, click on the Unit to Operate . (3) The screen will move to the various operation screens. (4) If the wrong function selection button is clicked, click on that button once again and the other...
Page 30 - Operation Monitor
29 3.7 Operation Monitor * Items Performed Here - Monitors the operating condition and operating data of the current units every minute. This information can be displayed and saved. * When an excessively large number of the objective unit for monitoring exists, the monitoring interval may exceed 1 m...
Page 31 - domain name; Mail communication Mode; Operation Status Monitor Screen
30 When [ Mail communication Mode ] is selected, the setting items of mail communication will be displayed. - From: Mail Address Set the mail address of the G-50A in the [From: Mail Address] field. When sending mail via an ISP, set the mail address allocated by the ISP. When the mail server resides ...
Page 32 - Click on to end the; Operating Status Monitor Screen; The message “; Finish the operation status monitor
31 (8) Click on to end the Operating Status Monitor Screen . The message “ Finish the operation status monitor ” will appear. Click on to end or click on to not end. Clicking displays the screen to save data. Change the data name as required and save it. You may enter your comment also. Clicking doe...
Page 33 - About LM ADAPTER; ] to end the operation status monitor and return to the Main Screen.[
32 * About LM ADAPTER Operation Monitor Item Performed Here Operation status of LM ADAPTER, current values of network variable and configration property,setting status of switch or the like. [ Refer to 3.7 Operation Monitor ] 1 Screen Transfer Operation To move to the screen monitoring LM ADAPTER op...
Page 34 - Introduction to the screen
33 3 Introduction to the screen Display Contents <Function set switch> Set status of function selector switch 0:OFF setting 1:ON setting <Extension switch> Set status of extension function selector switch 0:OFF setting 1:ON setting <M-NET address switch> Set status of M-NET address...
Page 38 - Items Performed Here; (1) Click on from the function selection buttons on the; Main Screen; will appear in the attribute column
37 3.8 Malfunction Log * Items Performed Here - The malfunction log of the most recent 10 cases (except operation group SC) 3.8.1 Screen Transfer Operation (1) Click on from the function selection buttons on the Main Screen . (2) Click on the units to be monitored (except operation group SC). (3) Th...
Page 42 - Screen; opens and the present time of PC is displayed.; Date / Time Setting Screen; and return to the
41 3.9.5 Date / Time Setting (1) Click on . The Date / Time Setting Screen opens and the present time of PC is displayed. * When the unit which does not correspond to a setup of time is chosen, the message of "This function is not available" is displayed, and it cannot set up. (2) A click of...
Page 43 - Operation Control
42 3.10 Operation Control * Items Performed Here - ON / OFF of the unit, the operation mode and setting the temperature can be performed in the same manner as a remote controller. 3.10.1 Screen Transfer Operation (1) Click on from the function selection buttons on the Main Screen . (2) Click on the ...
Page 44 - and; (1) Click on the button corresponding to the valve
43 3.10.3 Screen Functions and Operation(BC Controller) (1) Click on the button corresponding to the valve number you want to change. “0” represents “close” and “1” represents “open”. To change the valve setting, perform “Fix Release” --> “Fix” (2) After setting, click on . (3) Click on to check ...
Page 45 - Free contact of indoor unit
44 3.11 Free contact of indoor unit * Items Performed Here - When utilizing the [Indoor unit free contact mode] which uses the external input/output of Free Plan indoor unit (Building-Multi) together with G-50 and TG 2000, the contact action of the indoor unit can be tested with this function. 3.11....
Page 46 - The state where the button is being depressed
45 (2) Automatic monitoring To automatically monitor the contact status of indoor units of No.1 ~ 50 repeatedly, select the [Auto monitor] mode. a) Click the [Auto monitor] button on the mode selection section. The contact status of indoor units of No.1 ~ 50 will automatically be monitored, and this...
Page 47 - Title Screen; Operation Monitor; Off-Line Monitor Operating Method
46 4.1 Off-Line Monitor Screen Transfer Title Screen (Operation monitor Data list screen) (Operation status monitor screen) (System info. Data list screen) (Pre-error Data list screen) Operation Monitor System Information Monitoring of Pre-error Data 4 Off-Line Monitor Operating Method (System infor...
Page 48 - Monitors and prints about unit data saved in On-Line “; Delete Data
47 4.2 Function Chart 4.2.1 Operation Monitor Off-Line Analizing --------------------- [Refer to 4.3.1] Monitors and prints about unit data saved in On-Line “ 3.7 Operation Monitor ”. Graph --------------------- [Refer to 4.3.2] The operation data obtained can be graphed for display. Check Mail ----...
Page 49 - Operation Monitor
48 4.3 Operation Monitor * Items Performed Here - Monitors and prints about the System Information and the Operating Data of units saved using the on-line monitor. 4.3.1 Off-Line Analyzing (1) Click on to display the data list screen of Operation Monitor. (2) Click on [ Monitor Data ] desired to be ...
Page 53 - System Information
52 4.4 System Information 4.4.1 Off-Line Analyzing (1) Click on to display the data list screen of System Information. (2) Click on [ Monitor Data ] desired to monitor. (3) Click on . - The System Information Screen of Off-Line displays all connection information memorized by the connected G-50. Not...
Page 54 - Monitoring of Pre-error Data
53 4.5 Monitoring of Pre-error Data 4.5.1 Off-Line Analyzing (1) Click on to display the data list screen of Pre-error. (2) Click on [ Monitor Data ] desired to monitor. (3) Click on . Notice: This covers the operation with the menu of the right-clicking of the mouse. (Refer to 4.6.6 Right-clicking ...
Page 55 - column allows to sort the displayed data.; Monitor Data; The screen to store a file wiil be displayed.
54 4.6 Function common for each screen (Filing operation) * Clicking the button of "Monitor Data", "Monitor Date", "Last Updated" and "Others" at the upper column allows to sort the displayed data. * The right-clicking operation of the mouse covers the operation of ea...
Page 56 - Monitor Data information convert
55 4.6.4 Text Convert (1) Clicking to display Data list screen containing the file desired to edit. (Text conversion can also be adapted to the Pre-error data. For the converting method, refer to 4.5.1(5).) (2) Click on [ Monitor Data ] desired to convert into text format. (3) Click on . The screen ...
Page 58 - Offline Analyze on Wide area access mode; ) Display of monitored name objective for data collection.
57 4.7 Offline Analyze on Wide area access mode The function of the offline mode is mostly equals that of the normal mode, however, the following function is provided additionally. 1) Display of monitored name objective for data collection. - The [AREA name], [Customer name] and [Air conditioning sy...
Page 59 - File Names
58 5.1 System Information Data The data saved in Section " 3.4 Main Screen (2) " is stored in c:¥ProgramFiles¥mnttool32¥DATA - The following is an explanation of the file name SI_20040315_181026.MTDX Extension Monitor Time*1 Fixed (SI) 5.2 Operating Status Monitor Data The data saved in Sect...
Page 60 - How to Change Setting of Firewall for Windows XP; (1) Should the following symptoms occur at the Address; How to change the setting of Firewall; How to change setting of Firewall
59 How to Change Setting of Firewall for Windows XP 1. Introduction When connecting Maintenance Tool through G-50A, normal communication may not be performed if Firewall, the security function of Windows XP, has wholly been validated. (* In E-Mail mode and MN converter connection, it is not related)...
Page 63 - display the sub menu.
62 On the [Windows Security Alert] screen, if [Keep Blocking] or [Ask Me Later] has been selected, the settings of Firewall should be changed manually. The method of change is given below. (1) Select [Control Panel] from the Start menu. (2) The [Control Panel] screen will be displayed. (3) Click [Ne...