Mitsubishi FDC100VN- User Manual

Mitsubishi FDC100VN

Mitsubishi FDC100VN– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
Page: / 52

Table of Contents:

  • Page 2 – Micro Inverter
  • Page 4 – FDU; and Transparent inspection window.; FDUM
  • Page 6 – OUTDOOR UNIT
  • Page 8 – FDT; Easy checking of drain pan; Arrangement of installation
  • Page 10 – FDTC; “CLEARER”Air Flow; Installation Workability; Compact and Convenient; Quiet operation
  • Page 12 – Quiet, Lightweight and Compact; Enhanced installation workability
  • Page 16 – Increased freedom of a piping layout; Improved installation workability; Compact and modern design; FDEN; CEILING SUSPENDED
  • Page 18 – Wide and powerful air flow; FDF; FLOOR STANDING; Easy Transportation and Installation workability
  • Page 24 – Installation workability; in the industry and precharged refrigerant.; Piping length – 100m; Refrigerant precharged piping length extending to 30m
  • Page 26 – CEILING CASSETTE DUCT CONNECTED
  • Page 28 – MULTI SYSTEM; Decision of piping specification; Up to Four indoor units can be connected; By referring to the following table for applicable indoor units,; V Multi System; Twin type; Triple type
  • Page 38 – Jet Air Scroll; SRK; WALL MOUNTED; Long Reach Air Flow
  • Page 40 – Consideration on the Environment; All models employ R410A, with RoHS* directive; Convenience; Monitoring Function; Employment of lead-free solder; RoHS:Restriction of Hazardous substances; ENERGY LABEL
  • Page 42 – Control System
  • Page 44 – Main functions; Simple setting REMOTE CONTROL; Advanced touch screen panel with full dot Liquid Crystal display; All settings done by tapping touch screen panel; Simple setting by tapping button only; User friendly; Saving energy; High level of visibility; •Big LCD with 3.8 inch full dot display; Operation mode; Basic operation; The highest capacity operation; High power operation; •Changes set temperature.; Energy-saving operation
  • Page 46 – Wired remote control with weekly timer (option); Remote Control line up
  • Page 48 – OUTDOOR UNIT DIMENSIONS
Loading the manual

2014

14P01E

Safety Precautions

Before starting use

Air-conditioner usage target

The air-conditioner described in this catalog is a dedicated cooling/heating

device for human use.

Do not use it for special applications such as the storage of foodstuffs,

animals or plants, precision devices or valuable art, etc.

This could cause the quality of the items to drop, etc.

Do not use this for cooling vehicles or ships. Water leakage or current leaks

could occur.

Before use

Always read the "User,s Manual" thoroughly before starting use.

Installation

Always commission the installation to a dealer or specialist. Improper

installation will lead to water leakage, electric shocks and fires.

Make sure that the outdoor unit is stable in installation. Fix the unit to

stable base.

Usage place

Do not install in places where combustible gas could leak or where there

are sparks.

Installation in a place where combustible gas could be generated, flow or

accumulate, or places containing carbon fibers could lead to fires.

Refrigerant leakage

The refrigerant (R410A) used for Air conditioner is non-toxic and

inflammable in its original state.

However, in consideration of a state where the refrigerant leaks into the

room, measures against refrigerant leaks must be taken in small rooms

where the tolerable level could be exceeded. Take measures by installing

ventilation devices, etc.

Use in snowy areas

Take the following measures when installing the outdoor unit in snowy areas.

·Snow prevention

Install a snow-prevention hood so that the snow does not obstruct the air

intake port or enter and freeze in the outdoor unit.

·Snow piling

In areas with heavy snow fall, the piled snow could block the air intake

port. In this case, a frame that is 50cm or higher than the estimated snow

fall must be installed underneath the outdoor unit.

Automatic defrosting device

If the temperature is low, and the humidity is high, frost will stick to the

heat exchanger of the outdoor unit. If use is continued, the heating

performance will drop.

The "Automatic defrosting device" will function to remove this frost.

After heating for approx, three to ten minutes, it will stop, and the frost will

be removed. After defrosting, hot air will be blown again.

Servicing the air-conditioner

After the air-conditioner is used for several seasons, dirt will build up in

the air-conditioner causing the performance to drop. In addition to regular

servicing, we recommend the maintenance contract (charged for) by a

specialist.

Heating performance

The heating performance values (kW) described in catalog are the values

obtained by operating at an outdoor temperature of 7 C and indoor

temperature of 20 C as set forth in the ISO Standards. As the heating

performance decreases as the outdoor temperature drops, if the outdoor

temperature is too low and the heating performance is insufficient, use other

heating appliances as well.

Indication of sound values

The sound values are the values (A scale) measured in a chamber such as an

anechoic chamber following the ISO Standards. In the actual installation

state, the value is normally larger than the values given in the catalog due to

the effect of surrounding noise and echo. Take this into consideration when

installing.

Use in oil atmosphere

Avoid installing this unit in as atmosphere where oil scatters or builds up,

such as in a kitchen or machine factory.

If the oil adheres to the heat exchanger, the heat exchanging performance

will drop, mist may be generated, and the synthetic resin parts may deform

and break.

Use in acidic or alkaline atmosphere

If this unit is used in acidic atmosphere such as hot spring areas having high

level of sulfuric gases or in alkaline atmosphere including ammonia or

calcium chloride, places where the exhaust of the heat exchanger is sucked

in, or at coastal areas where the unit is subject to salt breezes, the outer plate

or heat exchanger, etc., will corrode. Please ask a dealer or specialist when

you use an air conditioner in places differing from a general atmosphere.

Use in places with high ceilings

If the ceiling is high, install a circulator to improve the heat and air flow

distribution when heating.

October 2013 R

HB91-14P01E

Our factories are ISO9001 and ISO14001 certified.

BIWAJIMA PLANT

Mitsubishi Heavy Industries, Ltd.

Air-conditioning & Refrigeration Systems Headquarters

Certificate number : JQA-0709

MITSUBISHI HEAVY INDUSTRIES-

MAHAJAK AIR CONDITIONERS CO., LTD.

Certificate Number : 04100 1998 0813

Mitsubishi Heavy

Industries-Haier (Quingdao)

Air-conditioners Co.,Ltd.

Certificate number : 01-1998-083

MITSUBISHI HEAVY INDUSTRIES-

MAHAJAK AIR CONDITIONERS CO.,LTD.

Certificate Number : 04104 1998 0813 E5

ISO 14001

Certificate

04104 1998 0813 E5

Mitsubishi Heavy

Industries-Haier (Quingdao)

Air-conditioners Co.,Ltd.

Certificate Number : 5170-1996-AQ-RCG-RvA

Certified ISO 9001

Certified ISO 14001

Because of our policy of continuous improvement, we reserve right to make changes in all specifications without notice.

Edited in Japan

Mitsubishi Heavy Industries, Ltd.

Air-Conditioning & Refrigeration Systems

16-5, Konan 2-chome, Minato-ku, Tokyo, 108-8215 Japan

http://www.mhi.co.jp

R410A

(COMPANY) participates in the ECC

programme for (PROGRAMME).

Check ongoing validity of certificate:

www.eurovent-certification.com or

www.certiflash.com

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Micro Inverter

3 2 -15˚C +43˚C -20˚C +20˚C 50 40 30 20 10 0 -10 -20 -30 Heating Cooling : Heating operation down to -20˚C: Nominal heating capacity maintained at -15˚C -20˚C -15˚C FDC100VSX(4HP, 3phase 380V)FDC125VSX(5HP, 3phase 380V)FDC140VSX(6HP, 3phase 380V) Micro Inverter Hyper Inverter 12.516.016.5 16.018.020...

Page 4 - FDU; and Transparent inspection window.; FDUM

5 4 Previous New Due to optimization of outlet design of air flow with our new advanced technology, sufficient air flow is secured and long reach of air flow is realized. (FDT) For person who is far from the indoor unit For both persons who are feeling hot or cold Can cool both the kitchen and the g...

Page 6 - OUTDOOR UNIT

7 6 SINGLE [OUTDOOR UNIT : INDOOR UNIT = 1 : 1] CEILING SUSPENDED WALL MOUNTED Type 4way FDT 4way compact (600 x 600mm) FDTC Low/Middle Static pressure FDUM High Static pressure FDU FDEN SRK CEILING CASSETTE DUCT CONNECTED FDTC40ZMXVF FDTC50ZMXVF FDTC60ZMXVF FDTC40VF FDTC50VF FDTC60VF SRC40ZMX-S SRC...

Other Mitsubishi Models