Mitsubishi PUHZ-W90VHA- User Manual

Mitsubishi PUHZ-W90VHA

Mitsubishi PUHZ-W90VHA– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
Page: / 45

Table of Contents:

  • Page 2 – SAFETY PRECAUTION; Cautions for units utilizing refrigerant R410A; Charge refrigerant from liquid phase of gas cylinder.
  • Page 3 – -3. CAUTIONS FOR REFRIGERANT PIPING WORK; Gravimeter
  • Page 4 – SPECIFICATIONS; Heating
  • Page 5 – DATA; MICROPHONE; BAND CENTER FREQUENCIES, Hz
  • Page 7 – OUTLINES AND DIMENSIONS; SERVICE SPACE
  • Page 8 – WIRING DIAGRAM
  • Page 9 – WIRING SPECIFICATIONS; FIELD ELECTRICAL WIRING (power wiring specifications); Outdoor unit power supply; SUHQHVKHDWKHGÀH[LEOHFDEOHV
  • Page 10 – REFRIGERANT SYSTEM DIAGRAM
  • Page 11 – TROUBLESHOOTING; nections and incorrect polarity.
  • Page 12 –
  • Page 13 –
  • Page 19 – Abnormal
  • Page 22 – Low temperature thermistor
  • Page 23 – ; Linear expansion valve; (1) Operation summary of the linear expansion valve; Output
  • Page 24 – (3) How to attach and detach the coil of linear expansion valve
  • Page 26 – Outdoor noise filter circuit board
  • Page 27 – Outdoor power circuit board; ACTM
  • Page 28 – Interface circuit board
  • Page 30 – -7. OUTDOOR UNIT OPERATION MONITOR FUNCTION; SW2 setting; Display detail; Operation indicator SW2 : Indicator change of self diagnosis; Display during error postponement; Display Inspection unit
  • Page 32 – Model
  • Page 33 – Unit
  • Page 35 – Hz
  • Page 38 – DISASSEMBLY PROCEDURE; OPERATING PROCEDURE; Removing the service panel and top panel; downward to remove the service panel.; Figure 1; (5) Disconnect the connector CNF1 on controller circuit board; Photo 1; Removing the electrical box; (5) Remove the terminal cover and disconnect the compressor; Photo 3
  • Page 39 – controller circuit board.; recover water in the plate heat exchanger.; Photo 4
  • Page 40 – on the controller circuit board.; Photo 8
  • Page 41 – of the unit and remove the right side panel.
  • Page 42 – Note 1: Recover refrigerant without letting it out in the air.; Note 1: Recover refrigerant without letting it out in the air.; the right side panel.
  • Page 43 – (5) Remove power circuit board from the electrical parts box.; Figure 2
Loading the manual

SERVICE MANUAL

AIR TO WATER HEAT PUMP

No. OCH419

CONTENTS

1. SAFETY PRECAUTION .......................................... 2

2. SPECIFICATIONS ..................................................... 4

3. DATA ............................................................................. 5

4. OUTLINES AND DIMENSIONS ............................ 7

5. WIRING DIAGRAM ................................................... 8

6. WIRING SPECIFICATIONS.................................... 9

7. REFRIGERANT SYSTEM DIAGRAM ...................10

8. TROUBLESHOOTING ...........................................11

9. DISASSEMBLY PROCEDURE ...........................38

August 2007

Note:

This manual describes only

service data of PUHZ-W90VHA.

RoHS compliant products have

<G> mark on the spec name plate.

R410A

[model name]

PUHZ-W90VHA

[Service Ref.]

PUHZ-W90VHA

PUHZ-W90VHA

PARTS CATALOG (OCB419)

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SAFETY PRECAUTION; Cautions for units utilizing refrigerant R410A; Charge refrigerant from liquid phase of gas cylinder.

2 SAFETY PRECAUTION 1 Cautions for units utilizing refrigerant R410A 1-2. CAUTIONS RELATED TO NEW REFRIGERANT 1-1. ALWAYS OBSERVE FOR SAFETY Before obtaining access to terminal, all supply ciucuits must be disconnected. [1] Cautions for service (1) Perform service after recovering the refrigerant le...

Page 3 - -3. CAUTIONS FOR REFRIGERANT PIPING WORK; Gravimeter

3 3 1-3. CAUTIONS FOR REFRIGERANT PIPING WORK Tools for R410A (The following table shows whether conventional tools can be used or not.) Gauge manifoldCharge hoseGas leak detectorRefrigerant recovery equipmentRefrigerant cylinderSafety charger Charge valve Vacuum pump BenderPipe cutterWelder and nit...

Page 4 - SPECIFICATIONS; Heating

4 SPECIFICATIONS 2 Power supply Phase 㱢 Voltage V n o i t i d n o c g n i t a r e p o l a n i m o N z H y c n e u q e r F Heating Capacity kW Heating(A2/W35) (A2/W35) 2 + ) b l u b - y r D ( e r u t a r e p m e t r i a e d i s t u O P O C 㷄 1 + ) b l u b - t e W ( e r u t a r e p m e t r i a e d i s...