Mitsubishi PKA-RP100FAL- User Manual

Mitsubishi PKA-RP100FAL

Mitsubishi PKA-RP100FAL– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
Page: / 40

Table of Contents:

  • Page 2 – REFERENCE MANUAL
  • Page 3 – SAFETY PRECAUTION; Direct charging from the cylinder.; Cautions for units utilizing refrigerant R407C; CAUTIONS RELATED TO NEW REFRIGERANT; Do not use the existing refrigerant piping.; Gravimeter
  • Page 5 – Cautions for units utilizing refrigerant R410A; Use new refrigerant pipes.; Be sure to use a filter drier for new refrigerant.
  • Page 6 – PART NAMES AND FUNCTIONS; Indoor Unit
  • Page 7 – Wireless remote controller
  • Page 8 – SPECIFICATIONS
  • Page 10 – NOISE CRITERION CURVES; UNIT
  • Page 11 – OUTLINES AND DIMENSIONS
  • Page 13 – WIRING DIAGRAM
  • Page 14 – REFRIGERANT SYSTEM DIAGRAM; Heat exchanger
  • Page 15 – TROUBLESHOOTING
  • Page 16 – Malfunction-diagnosis method at maintenance service>
  • Page 23 – -4. TROUBLESHOOTING BY INFERIOR PHENOMENA
  • Page 26 – Vane motor; Thermistor R
  • Page 29 – -8. FUNCTIONS OF DIP SWITCH AND JUMPER WIRE
  • Page 30 – DISASSEMBLY PROCEDURE; OPERATING PROCEDURE; Removing the lower side of the indoor unit from the; Removing the indoor controller board; Figure 1
  • Page 31 – Removing the vane motor; Photo 6
  • Page 32 – Removing the line flow fan and the fan motor; Photo 9
  • Page 33 – PARTS LIST; Part numbers that is circled is not shown in the figure.
  • Page 34 – Continued to the next page.
  • Page 35 – From the previous page.
  • Page 36 – ELECTRICAL PARTS
  • Page 40 – TM
Loading the manual

SERVICE MANUAL

CONTENTS

1. REFERENCE MANUAL ·······································2

2. SAFETY PRECAUTION ·······································3

3. PART NAMES AND FUNCTIONS ·······················6

4. SPECIFICATIONS ················································8

5. NOISE CRITERION CURVES ····························10

6. OUTLINES AND DIMENSIONS ·························11

7. WIRING DIAGRAM ············································13

8. REFRIGERANT SYSTEM DIAGRAM ······················14

9. TROUBLE SHOOTING ······································15

10. DISASSEMBLY PROCEDURE ··························30

11. PARTS LIST ·······················································33

Indoor unit

[Model names]

[Service Ref.]

PKA-RP60FAL

PKA-RP60FAL

PKA-RP71FAL

PKA-RP71FAL

PKA-RP100FAL

PKA-RP100FAL

Indoor unit

No.OC331

Remote controller

SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
SPLIT-TYPE, AIR CONDITIONERS

This manual describes only

service data of the indoor
units.

Model name
indication

PKH-P60FALH

PKH-P60FALH

PKH-P71FALH

PKH-P71FALH

PKH-P100FALH

PKH-P100FALH

May 2005

OC331--1.qxp 05.5.17 9:26 AM Page 1

Back to Index

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - REFERENCE MANUAL

2 1 REFERENCE MANUAL Service Ref. PUHZ-RP35/50/60/71/100/125/140VHAPUHZ-RP100/125/140YHAPUHZ-RP71/100/125/140VHA-A PUHZ-RP200/250YHA PUHZ-RP200/250YHA-A PU(H)-P·VGAA.UKPU(H)-P·YGAA.UK Service Manual No. OC334 OC337 OC338 OC339 OC336 1-1. OUTDOOR UNIT’S SERVICE MANUAL Series (Outdoor unit) PUHZ-RP·VH...

Page 3 - SAFETY PRECAUTION; Direct charging from the cylinder.; Cautions for units utilizing refrigerant R407C; CAUTIONS RELATED TO NEW REFRIGERANT; Do not use the existing refrigerant piping.; Gravimeter

3 2 SAFETY PRECAUTION [2] Refrigerant recharging (1) Refrigerant recharging process 1 Direct charging from the cylinder. ·R407C cylinder are available on the market has a syphon pipe.·Leave the syphon pipe cylinder standing and recharge it. (By liquid refrigerant) (2) Recharge in refrigerant leakage...

Page 5 - Cautions for units utilizing refrigerant R410A; Use new refrigerant pipes.; Be sure to use a filter drier for new refrigerant.

5 Cautions for units utilizing refrigerant R410A CAUTIONS RELATED TO NEW REFRIGERANT Use new refrigerant pipes. Make sure that the inside and outside of refrige-rant piping is clean and it has no contaminationsuch as sulfur hazardous for use, oxides, dirt, shaving particles, etc.In addition, use pip...