Mitsubishi Electric MUYGL18NA-U1 - User Manual

Mitsubishi Electric MUYGL18NA-U1

Mitsubishi Electric MUYGL18NA-U1 Air Conditioner – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
Page: / 76

Table of Contents:

  • Page 2 – Use the specified refrigerant only; Never use any refrigerant other than that specified.; WARNING; refrigerant pipes. The compressor may burst if air etc. get into it.
  • Page 3 – TECHNICAL CHANGES; Piping; PART NAMES AND FUNCTIONS; Air outlet
  • Page 4 – SPECIFICATION; Airflow; MUZ; External finish; NOTE
  • Page 5 – Height difference
  • Page 6 – Test condition; OPERATING RANGE
  • Page 7 – OUTLINES AND DIMENSIONS; REQUIRED SPACE
  • Page 9 – WIRING DIAGRAM
  • Page 21 – REFRIGERANT SYSTEM DIAGRAM; Service port
  • Page 23 – MAX. REFRIGERANT PIPING LENGTH and MAX. HEIGHT DIFFERENCE; Max. Height difference
  • Page 24 – DATA; ) COOLING CAPACITY; SHC is based on 80 ̊F of indoor Intake air DB temperature.
  • Page 25 – ) COOLING CAPACITY CORRECTIONS; ) HEATING CAPACITY CORRECTIONS; Model
  • Page 27 – Cooling; between frequency and capacity.
  • Page 28 – Heating
  • Page 30 – Data are based on the condition of indoor humidity 50 %.
  • Page 32 – Data are based on the condition of outdoor humidity 75%.
  • Page 37 – -5. CAPACITY AND INPUT CORRECTION BY INVERTER OUTPUT FREQUENCY
  • Page 39 – ACTUATOR CONTROL; The fan motor turns ON/OFF, interlocking with the compressor.; -3. RELATION BETWEEN MAIN SENSOR AND ACTUATOR
  • Page 40 – SERVICE FUNCTIONS
  • Page 41 – 0 TROUBLESHOOTING; Before troubleshooting, check the following; burnt or discolored components.
  • Page 42 – Outline of the function; Flow chart of failure mode recall function; Operational procedure
  • Page 44 – Table of outdoor unit failure mode recall function; Blinking patterns of this mode differ from the ones of
  • Page 48 – 0-4. TROUBLESHOOTING CRITERION OF MAIN PARTS
  • Page 49 – the voltage balance
  • Page 50 – Confirm that
  • Page 51 – G Check of outdoor thermistors
  • Page 53 – I Check of outdoor fan motor
  • Page 54 – J Check of power supply
  • Page 55 – Properly fix the LEV coil to the expansion valve.
  • Page 57 – M How to check miswiring and serial signal error
  • Page 59 – Other models
  • Page 60 – P Electromagnetic noise enters into TV sets or radios
  • Page 62 – Front side of unit
  • Page 64 – LED; Heater connector
  • Page 65 – OPERATING PROCEDURE; Removing the cabinet; ; DISASSEMBLY INSTRUCTIONS
  • Page 66 – Photo 4; Photo 6; Photo 7
  • Page 67 – Removing the discharge temperature thermistor,; Photo 8
  • Page 68 – Removing outdoor fan motor; Removing the compressor and 4-way valve
  • Page 70 – Photo 5
  • Page 76 – Specifications are subject to change without notice.
Loading the manual

HFC

utilized

R410A

INDOOR UNIT

SERVICE MANUAL

No. OBH733

REVISED EDITION-J

Indoor unit service manual

MSZ-GL•NA, MSY-GL•NA Series (OBH732)

MUZ-GL18/24NA

MUZ-GL18/24NAH

MUY-GL18/24NA

PARTS CATALOG (OBB733)

OBH733 REVISED EDITION-H is void.

Revision J:

• A warning when opening or closing the valve has

been added.

CONTENTS

1. TECHNICAL CHANGES ······························3

2. PART NAMES AND FUNCTIONS ··················3

3. SPECIFICATION ········································4

4. OUTLINES AND DIMENSIONS ·····················7

5. WIRING DIAGRAM ·····································9

6. REFRIGERANT SYSTEM DIAGRAM ··········· 21

7. DATA······················································ 24

8. ACTUATOR CONTROL ····························· 39

9. SERVICE FUNCTIONS ······························ 40

10. TROUBLESHOOTING ······························· 41

11. DISASSEMBLY INSTRUCTIONS ················· 65

OUTDOOR UNIT

Models

MUZ-GL09NA -

U1

,

U2

,

U8

MUZ-GL09NAH -

U1

,

U2

,

U8

MUY-GL09NA -

U1

,

U2

MUZ-GL12NA -

U1

,

U2

MUZ-GL12NAH -

U1

,

U2

MUY-GL12NA -

U1

,

U2

MUZ-GL15NA -

U1

,

U2

MUZ-GL15NAH -

U1

,

U2

MUY-GL15NA -

U1

,

U2

MUZ-GL18NA -

U1

MUZ-GL18NAH -

U1

MUY-GL18NA -

U1

MUZ-GL24NA -

U1

,

U2

MUZ-GL24NAH -

U1

MUY-GL24NA -

U1

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Use the specified refrigerant only; Never use any refrigerant other than that specified.; WARNING; refrigerant pipes. The compressor may burst if air etc. get into it.

2 Use the specified refrigerant only Never use any refrigerant other than that specified. Doing so may cause a burst, an explosion, or fire when the unit is being used, serviced, or disposed of. Correct refrigerant is specified in the manuals and on the spec labels provided with our products. We wil...

Page 3 - TECHNICAL CHANGES; Piping; PART NAMES AND FUNCTIONS; Air outlet

3 1 TECHNICAL CHANGES MUZ-GL18NA MUZ-GL18NAH MUY-GL18NA MUZ-GL24NA MUZ-GL24NAH MUY-GL24NA Piping Air outlet Drain outlet Air inlet (back and side) Drain hose PART NAMES AND FUNCTIONS 2 MUZ-GL09NA - U1 MUZ-GL09NAH - U1 MUY-GL09NA - U1 MUZ-GL09NA - U8 MUZ-GL09NAH - U8 MUZ-GL12NA - U1 MUZ-GL12NAH - U1 ...

Page 4 - SPECIFICATION; Airflow; MUZ; External finish; NOTE

4 3 SPECIFICATION Outdoor unit model MUZ- MUY- MUZ- MUY- GL09NA - U1 GL09NAH - U1 GL09NA - U2 GL09NAH - U2 GL09NA - U8 GL09NAH - U8 GL09NA - U1 GL09NA - U2 GL12NA GL12NAH GL12NA Capacity Rated (Minimum~Maximum) Cooling *1 Btu/h 9,000 (3,600 - 12,200) 12,000 (1,500 - 13,600) Heating 47 *1 ( MUZ ) Btu...

Other Mitsubishi Electric Air Conditioners Models

All Mitsubishi Electric Air Conditioners