Mitsubishi Electric MSYGL09NA-U1 - User Manual

Mitsubishi Electric MSYGL09NA-U1

Mitsubishi Electric MSYGL09NA-U1 Air Conditioner – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
Page: / 52

Table of Contents:

  • Page 2 – TECHNICAL CHANGES; Use the specified refrigerant only; Never use any refrigerant other than that specified.; failure to follow the instructions.
  • Page 3 – PART NAMES AND FUNCTIONS; Remote control receiving section; Display section; ACCESSORIES; Installation plate
  • Page 5 – Remote controller; Operation indicator lamp; Emergency operation switch
  • Page 6 – SPECIFICATION
  • Page 8 – OUTLINES AND DIMENSIONS
  • Page 10 – WIRING DIAGRAM
  • Page 12 – REFRIGERANT SYSTEM DIAGRAM
  • Page 13 – Table 1; unit operation; SERVICE FUNCTIONS
  • Page 15 – WIRELESS REMOTE CONTROLLER; remote controller with beeps.; MICROPROCESSOR CONTROL; Indication of
  • Page 16 – Operation Indicator lamp; Room temperature; INDOOR UNIT DISPLAY SECTION
  • Page 18 – units to the same operation mode.
  • Page 20 – or
  • Page 21 – • “ ” and “ ” display shows the order of OFF timer and ON timer operation.; PROGRAM TIMER; NOTE; cancelled when power is restored.; How to SET SMART SET operation; • The setting range of HEAT; How to cancel operation; • Press SMART SET button again.
  • Page 22 – TIMER is cancelled and the display of set time disappears.; The operation mode is indicated by the Operation
  • Page 23 – Lead wiring; RESET button; then use the remote controller.; TROUBLESHOOTING
  • Page 24 – Outline of the function; Flow chart of failure mode recall function
  • Page 25 – Indoor unit failure mode table
  • Page 27 – OPERATION INDICATOR
  • Page 29 – A Check of indoor fan motor
  • Page 32 – C Check of indoor P.C. board and indoor fan motor
  • Page 35 – D How to check miswiring and serial signal error
  • Page 37 – E Electromagnetic noise enters into TV sets or radios
  • Page 39 – mode point
  • Page 41 – Removing the panel; it; Photo 1; DISASSEMBLY INSTRUCTIONS
  • Page 42 – board and the room temperature thermistor; control
  • Page 43 – Removing the nozzle assembly; (4) Pull out the drain hose from the nozzle assembly and; Photo 5; (3) Disconnect the connector from the horizontal vane
  • Page 45 – (1) Remove the screw caps on the panel and remove the; Screws of the panel
  • Page 46 – electrical box
  • Page 47 – board; Room temperature thermistor
  • Page 48 – the heat
  • Page 51 – the indoor coil thermistor, and the line flow fan; receiver holder; Figure 1
  • Page 52 – Fixing the indoor coil thermistor; There are 2 forms of parts for fixing the indoor coil thermistor.; Holder shape; When fixing the indoor coil thermistor; Position and procedure for mounting the clip-shape part; © Copyright 2015 MITSUBISHI ELECTRIC CORPORATION; Specifications are subject to change without notice.
Loading the manual

SERVICE MANUAL

CONTENTS

1. TECHNICAL CHANGES

· ·······························

2

2. PART NAMES AND FUNCTIONS ··················3

3. SPECIFICATION ········································6

4. OUTLINES AND DIMENSIONS ·····················8

5. WIRING DIAGRAM ··································· 10

6. REFRIGERANT SYSTEM DIAGRAM ··········· 12

7. SERVICE FUNCTIONS ······························ 13

8. MICROPROCESSOR CONTROL ················ 15

9. TROUBLESHOOTING ······························· 23

10. DISASSEMBLY INSTRUCTIONS ················· 41

No. OBH732

REVISED EDITION-C

Outdoor unit service manual

MUZ-GL

NA, MUY-GL

NA Series (OBH733)

MXZ-C

NA, MXZ-C

NAHZ Series (OCH573)

NOTE:

RoHS compliant products have <G> mark on the spec name plate.

PARTS CATALOG (OBB732)

MSZ-GL06NA -

U1

MSZ-GL09NA -

U1

MSZ-GL12NA -

U1

MSZ-GL15NA -

U1

MSZ-GL18NA -

U1

MSZ-GL24NA -

U1

Models

MSZ-GL18NA

MSY-GL18NA

INDOOR UNIT

Revision C:

• For the airflow of

MSZ-GL24NA-

U1

and

MSY-

GL24NA-

U1

on the specification table has

been corrected (3. SPECIFICATION).

OBH732 REVISED EDITION-A is void.

MSY-GL09NA -

U1

MSY-GL12NA -

U1

MSY-GL15NA -

U1

MSY-GL18NA -

U1

MSY-GL24NA -

U1

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TECHNICAL CHANGES; Use the specified refrigerant only; Never use any refrigerant other than that specified.; failure to follow the instructions.

2 MSZ-GL18NA - U1 MSY-GL18NA - U1 MSZ-GL24NA - U1 MSY-GL24NA - U1 1. New model 1 TECHNICAL CHANGES Use the specified refrigerant only Never use any refrigerant other than that specified. Doing so may cause a burst, an explosion, or fire when the unit is being used, serviced, or disposed of. Correct ...

Page 3 - PART NAMES AND FUNCTIONS; Remote control receiving section; Display section; ACCESSORIES; Installation plate

3 2 PART NAMES AND FUNCTIONS MSZ-GL06NA MSZ-GL09NA MSZ-GL12NA MSZ-GL15NA MSY-GL09NA MSY-GL12NA MSY-GL15NA Remote controller Operation indicator lamp Remote control receiving section Emergency operation switch Horizontal vane Air outlet Air fi lter Air inlet Heat exchanger Front panel Air cleaning fi l...

Page 5 - Remote controller; Operation indicator lamp; Emergency operation switch

5 Remote controller Display section Front panel Air fi lter (Nano platinum filter) Air inlet Air cleaning filter (Electrostatic anti-allergy enzyme filter) Air outlet Horizontal vane Heat exchanger Operation indicator lamp Remote control receiving section Emergency operation switch MSZ-GL24NA MSY-GL2...

Other Mitsubishi Electric Air Conditioners Models

All Mitsubishi Electric Air Conditioners