Milwaukee 5619-20 Wiring- User Manual

Milwaukee 5619-20 Wiring

Milwaukee 5619-20 Wiring– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
Page: / 2
Loading the manual

WIRING INSTRUCTIONS

1

Black

22-64-0815

4-3/4"

Component of cord assembly. Strip 3/16" for T1.

2

White

22-64-0815

4-3/4"

Component of cord assembly. Strip 3/16" for T3.

3

Black

23-66-2275

2-1/2"

Component of switch assembly. Strip 3/16" for T2.

4

Black

22-64-0820

3"

Component of power cord assembly. Strip 3/16" for T4.

5

White

22-64-0820

4"

Component of power cord assembly. Strip 3/16" for T4.

6

Black

23-33-0065

4"

Component of receptacle outlet assy. Strip 3/16" for T4.

7

White

23-33-0065

3"

Component of receptacle outlet assy. Strip 3/16" for T4.

D-HANDLE ROUTER

58-01-0715

DATE

Oct. 2003

MILWAUKEE ELECTRIC TOOL CORP. 13135 WEST LISBON RD. BROOKFIELD, WIS.

BULLETIN

TITLE

Drwg. 2

Terminals, Connectors and 1 or 2 End Wire Preparation

Wire

Color

Origin or

Gauge

Wire

No.

Length

WIRING SPECIFICATIONS

TERMINAL DESCRIPTION

Part No.

Code

Qnty.

T1

23-74-0065

1

T2

23-74-1060

1

T3

23-74-0605

1

T4

23-74-0850

4

BULK LEAD WIRE - BULLETIN NO. 58-01-0003

NOTE:

All lead lengths are before stripping.
All leads must be held to ± .125"
unless specified elsewhere.
Strip wire per ES 13-11.
Crimp terminals per ES 13-15.

White

Black

Black

White

White

Black

Black

White

White

Black

Black

From

receptacle

outlet

From power cord

Connector

terminal

No. 23-74-0055

Cord jacket to extend past
cord clamp approx. 1/4".

Remove slack from cord wires #1

and #2 between wire traps. Wires

are not to extend into frame

opening.

Black cord wire #1 is connected

to the switch. White cord wire #2

is connected to the field

terminal, as shown.

Route black switch lead #3 to

brush holder, as shown.

Black switch lead #3 must be

placed in wire trap prior to

white cord lead #2.

Order of cord

wires in traps is

interchangeable.

Route brush

shunt wires

(2 places) to

brush holder,

as shown.

Route white

wires #5 and #7

to the top (trigger end)

of the switch. Route black

wires #4 and #6 to the

bottom of the switch.

Insert cord plug into

receptacle outlet.

T4

SEE REVERSE SIDE FOR MODELS WHERE WIRE

#3 IS A SEPARATE LEADWIRE ASSEMBLY AND

IS NOT SOLDERED TO THE SWITCH.