WIRING INSTRUCTIONS
1
Black
22-64-0815
4-3/4"
Component of cord assembly. Strip 3/16" for T1.
2
White
22-64-0815
4-3/4"
Component of cord assembly. Strip 3/16" for T3.
3
Black
23-66-2275
2-1/2"
Component of switch assembly. Strip 3/16" for T2.
4
Black
22-64-0820
3"
Component of power cord assembly. Strip 3/16" for T4.
5
White
22-64-0820
4"
Component of power cord assembly. Strip 3/16" for T4.
6
Black
23-33-0065
4"
Component of receptacle outlet assy. Strip 3/16" for T4.
7
White
23-33-0065
3"
Component of receptacle outlet assy. Strip 3/16" for T4.
D-HANDLE ROUTER
58-01-0715
DATE
Oct. 2003
MILWAUKEE ELECTRIC TOOL CORP. 13135 WEST LISBON RD. BROOKFIELD, WIS.
BULLETIN
TITLE
Drwg. 2
Terminals, Connectors and 1 or 2 End Wire Preparation
Wire
Color
Origin or
Gauge
Wire
No.
Length
WIRING SPECIFICATIONS
TERMINAL DESCRIPTION
Part No.
Code
Qnty.
T1
23-74-0065
1
T2
23-74-1060
1
T3
23-74-0605
1
T4
23-74-0850
4
BULK LEAD WIRE - BULLETIN NO. 58-01-0003
NOTE:
All lead lengths are before stripping.
All leads must be held to ± .125"
unless specified elsewhere.
Strip wire per ES 13-11.
Crimp terminals per ES 13-15.
White
Black
Black
White
White
Black
Black
White
White
Black
Black
From
receptacle
outlet
From power cord
Connector
terminal
No. 23-74-0055
Cord jacket to extend past
cord clamp approx. 1/4".
Remove slack from cord wires #1
and #2 between wire traps. Wires
are not to extend into frame
opening.
Black cord wire #1 is connected
to the switch. White cord wire #2
is connected to the field
terminal, as shown.
Route black switch lead #3 to
brush holder, as shown.
Black switch lead #3 must be
placed in wire trap prior to
white cord lead #2.
Order of cord
wires in traps is
interchangeable.
Route brush
shunt wires
(2 places) to
brush holder,
as shown.
Route white
wires #5 and #7
to the top (trigger end)
of the switch. Route black
wires #4 and #6 to the
bottom of the switch.
Insert cord plug into
receptacle outlet.
T4
SEE REVERSE SIDE FOR MODELS WHERE WIRE
#3 IS A SEPARATE LEADWIRE ASSEMBLY AND
IS NOT SOLDERED TO THE SWITCH.