Milwaukee 5615-24 Wiring- User Manual
Milwaukee 5615-24 Wiring– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
WIRING INSTRUCTIONS
TITLE
DATE
MILWAUKEE ELECTRIC TOOL CORP. 13135 WEST LISBON RD. BROOKFIELD, WIS.
BODY GRIP ROUTER
58-01-0705
BULLETIN
Oct. 2003
NOTE:
All lead lengths are before stripping.
All leads must be held to ± .125"
unless specified elsewhere.
Strip wire per ES 13-11.
Crimp terminals per ES 13-15.
Drwg. 2
TERMINAL DESCRIPTION
Qty.
Code
Part No.
T1
23-74-0065
1
T2
23-74-1060
1
T3
23-74-0605
1
Wire
Wire
Origin or
No.
Color
Part No.
Gauge
Length
Terminals, Connectors and End Wire Preparation
1
Black
Cord
16
4-3/4"
Component of cord assembly. Strip 3/16" for T1.
2
White
Cord
16
4-3/4"
Component of cord assembly. Strip 3/16" for T3.
3
Black
Switch
18
2-1/2"
Component of switch assembly. Strip 3/16" for T2.
BULK LEAD WIRE - BULLETIN 58-01-0003
WIRING SPECIFICATIONS
Remove slack from cord wires #1
and #2 between wire traps. Wires
are not to extend into frame
opening.
Black cord wire #1 is
connected to the switch.
White cord wire #2 is
connected to the field
terminal as shown.
Route black switch lead #3
to brush holder, as shown.
Black switch lead #3 must
be placed in wire trap prior
to white cord lead #2.
Order of cord wire placement
in traps are interchangeable.
Route brush shunt wires
(2 places) to brush holder,
as shown.
Cord jacket to extend past
cord clamp approx. 1/4".
Top View
WIRING SCHEMATIC
Connector Terminal (Jumper)
No. 23-74-0055
Black
Black
White
FIELD
CORD
ARM
SEE REVERSE SIDE FOR MODELS
WHERE WIRE #3 IS A SEPARATE
LEADWIRE ASSEMBLY AND IS NOT
SOLDERED TO THE SWITCH.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.