Page 2 - From Miller to You; Thank you; To locate your nearest
From Miller to You Mil_Thank1 2019 01 Miller is the first welding equipment manufacturer in theU. S. A. to be registered to theISO 9001 Quality System Standard. Working as hard as you do −every power source from Miller is backed by the mosthassle-free warranty in thebusiness. From Miller to You Than...
Page 3 - TABLE OF CONTENTS
TABLE OF CONTENTS SECTION 1 – SAFETY PRECAUTIONS – READ BEFORE USING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1-1 Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 5 - DECLARATION OF CONFORMITY; declares that the; Council Directives and Commission Regulations:; 014/30/EU Electromagnetic compatibility; David A. Werba
DECLARATION OF CONFORMITY for European Community (CE marked) products. MILLER Electric Mfg. LLC, 1635 Spencer Street, Appleton, WI 54914 U.S.A. declares that the product(s) identified in this declaration conform to the essential requirements and provisions of the stated Council Directive(s), Commi...
Page 6 - declares that
DECLARATION OF CONFORMITY For United Kingdom (UKCA marked) products. MILLER Electric Mfg. LLC, 1635 West Spencer Street, Appleton, WI 54914 U.S.A. declares that the product(s) identified in this declaration conform to the essential requirements and provisions of the stated Regulation(s) and Standard...
Page 7 - EMF DATA SHEET FOR ARC WELDING POWER SOURCE; Product/Apparatus Identification
EMF DATA SHEET FOR ARC WELDING POWER SOURCE Product/Apparatus Identification Product Stock Number DYNASTY 350 (AUTO-LINE 380-575)CE 907204021 DYNASTY 400 (AUTO-LINE 380-575)CE 907717002 SYNCROWAVE 400 380-400, CE 907783002 SYNCROWAVE 400 TIGRUNNER 380-400, CE 907783003 Compliance Information Summary...
Page 11 - SECTION 1 – SAFETY PRECAUTIONS – READ BEFORE USING; Symbol Usage; Arc Welding Hazards; ELECTRIC SHOCK can kill.
OM-290047 Page 1 SECTION 1 – SAFETY PRECAUTIONS – READ BEFORE USING Protect yourself and others from injury—read, follow, and save these important safety precautions and operating instructions. 1-1. Symbol Usage DANGER! – Indicates a hazardous situation which, if notavoided, will result in death or ...
Page 13 - Additional Hazards For Installation, Operation, And Maintenance
OM-290047 Page 3 CYLINDERS can explode if damaged. Compressed gas cylinders contain gas under highpressure. If damaged, a cylinder can explode.Since gas cylinders are normally part of the weld- ing process, be sure to treat them carefully. � Protect compressed gas cylinders from excessive heat, mech...
Page 14 - ARC WELDING can cause; California Proposition 65 Warnings; EMF Information
OM-290047 Page 4 ARC WELDING can cause interference. � Electromagnetic energy can interfere with sensitiveelectronic equipment such as microprocessors,computers, and computer-driven equipment such as robots. � Be sure all equipment in the welding area is electromagneticallycompatible. � To reduce po...
Page 15 - Symboles utilisés; Dangers relatifs au soudage à l’arc; UNE DÉCHARGE ÉLECTRIQUE peut
OM-290047 Page 5 SECTION 2 – CONSIGNES DE SÉCURITÉ - LIRE AVANT UTILISATION Pour écarter les risques de blessure pour vous-même et pour autrui — lire, appliquer et ranger en lieu sûr ces consignes relativesaux précautions de sécurité et au mode opératoire. 2-1. Symboles utilisés DANGER! – Indique un...
Page 17 - fonctionnement et la maintenance
OM-290047 Page 7 � Brancher le câble de masse sur la pièce le plus près possible dela zone de soudage pour éviter le transport du courant sur une lon-gue distance par des chemins inconnus éventuels en provoquantdes risques d’électrocution, d’étincelles et d’incendie. � Ne pas utiliser le poste de so...
Page 19 - Informations relatives aux CEM
OM-290047 Page 9 2-4. Proposition californienne 65 Avertissements AVERTISSEMENT – Ce produit peut vous exposer à des pro-duits chimiques tels que le plomb, reconnus par l’État deCalifornie comme cancérigènes et sources de malforma-tions ou d’autres troubles de la reproduction. Pour plus d’informatio...
Page 20 - SECTION 3 – DEFINITIONS; Additional Safety Symbol Definitions; Additional Safety Symbols And Definitions; Additional Safety Symbols And Definitions; Additional Safety Symbols And Definitions; Additional Safety Symbols And Definitions; Additional Safety Symbols And Definitions
OM-290047 Page 10 � Complete Parts List is available at www.MillerWelds.com SECTION 3 – DEFINITIONS 3-1. Additional Safety Symbol Definitions � Some symbols are found only on CE products. Warning! Watch Out! There are possible hazards as shown by thesymbols. OM- 1-1. Additional Safety Symbols And De...
Page 22 - Miscellaneous Symbols And Definitions
OM-290047 Page 12 � Complete Parts List is available at www.MillerWelds.com OM- Hazardous voltage remains on input capacitors after power is turnedoff. Do not touch fully charged capacitors. Always wait 60 seconds after power is turned off before working on unit, AND check input ca-pacitor voltage, ...
Page 24 - SECTION 4 – SPECIFICATIONS; Serial Number And Rating Label Location; Specifications; A. Dynasty 400 Models
OM-290047 Page 14 � Complete Parts List is available at www.MillerWelds.com SECTION 4 – SPECIFICATIONS 4-1. Serial Number And Rating Label Location The serial number and rating information for the power source is located on the front of the machine. Use the rating labels to determine inputpower requ...
Page 25 - B. Maxstar 400 Models
OM-290047 Page 15 � Complete Parts List is available at www.MillerWelds.com B. Maxstar 400 Models Welding Amperage Range Max. Open Circuit Voltage (U 0 ) Low Open-Circuit Voltage (U 0 ) Rated Peak Striking Voltage (U p ) 3–400 A Welding range for Stick process is 5–400 amperes. For TIG, theamperage ...
Page 26 - D. Maxstar 800 Models; Dimensions, Weights, And Base Mounting Hole Layout; Dimensions, Weights And Base Mounting Hole Layout; A. Welding Power Source
OM-290047 Page 16 � Complete Parts List is available at www.MillerWelds.com D. Maxstar 800 Models Welding Amperage Range Max. Open Circuit Voltage (U 0 ) Low Open-Circuit Voltage (U 0 ) Rated Peak Striking Voltage (U p ) 5–800 A Welding range for Stick process is 5–750 amperes. For TIG, theamperage ...
Page 27 - B. Welding Power Source With Cart And Cooler; Environmental Specifications; B. Temperature Specifications
OM-290047 Page 17 � Complete Parts List is available at www.MillerWelds.com B. Welding Power Source With Cart And Cooler A complete Parts List is available at www.MillerWelds.com 1-3. Dimensions, Weights And Base Mounting Hole Layout A. Welding Power Source B A C 803914-A C D F G E B. Welding Power ...
Page 28 - G. China EEP Hazardous Substance Information
OM-290047 Page 18 � Complete Parts List is available at www.MillerWelds.com E. Information On Electromagnetic Compatibility (EMC) (Dynasty 800) This Class A equipment is not intended for use in residential locations where the electrical power is provided by the publiclow-voltage supply system. There...
Page 29 - H. EU Ecodesign Information
OM-290047 Page 19 � Complete Parts List is available at www.MillerWelds.com H. EU Ecodesign Information Model Input Minimum Power Source Efficiency Maximum Idle State Power Consumption Dynasty 400 400V Three Phase 80.0% 33.4 W Dynasty 800 400V Three Phase 82.2% 56.0 W Maxstar 400 400V Three Phase 86...
Page 30 - Duty Cycle And Overheating; A or V; Static Characteristics
OM-290047 Page 20 � Complete Parts List is available at www.MillerWelds.com 4-7. Duty Cycle And Overheating Duty Cycle is percentage of 10 minutes thatunit can weld at rated load without overheating. If unit overheats, output stops, a Help mes-sage is displayed (see Section 11-3), andcooling fan run...
Page 31 - SECTION 5 – INSTALLATION; Selecting A Location; Selecting A Location; Selecting A Location
OM-290047 Page 21 � Complete Parts List is available at www.MillerWelds.com SECTION 5 – INSTALLATION 5-1. Selecting A Location Movement A complete Parts List is available at www.MillerWelds.com OM- Writers: Remember to move unit dimension and weight and rating la-bel location information to the appr...
Page 32 - SECTION 2 INSTALLATION; Weld Output Terminals
OM-290047 Page 22 � Complete Parts List is available at www.MillerWelds.com 5-2. Weld Output Terminals A complete Parts List is available at www.MillerWelds.com SECTION 2 INSTALLATION 2-1. Weld Output Terminals 804746-B 2 1 3 Turn off power before connectingto weld output terminals. Do not use worn,...
Page 33 - Remote 14 Receptacle Information
OM-290047 Page 23 � Complete Parts List is available at www.MillerWelds.com 5-4. Remote 14 Receptacle Information 2-2. Remote 14 Receptacle Information 804746-B / 218716-A A J B K I C L N H D M G E F 2-3. Simple Automation Application (14-Pin Interface) R CR1 + CR1 To User Equipment Pin I, J: Collec...
Page 34 - A. Basic Automation Mode; Remote Memory Select Inputs (For 28-Pin Receptacle If Present)
OM-290047 Page 24 � Complete Parts List is available at www.MillerWelds.com 5-6. Automation Connection For 28-Pin Receptacle (If Present) A. Basic Automation Mode Use this mode when only the basic functions of the automation board are required. These functions include Start/Stop, Valid Arc Indicatio...
Page 37 - Remote Memory Select Inputs For 28-Pin Receptacle (If Present)
OM-290047 Page 27 � Complete Parts List is available at www.MillerWelds.com 3 Input Gas Control This input is used to control the gas flow outside the settings of the preflowand/or postflow set on the machine. Connection to pin 8 turns on gas. 4 Output Valid Arc Indication Paired with Pin 9. This ou...
Page 38 - Gas Connections
OM-290047 Page 28 � Complete Parts List is available at www.MillerWelds.com 5-8. 115 Volts AC Cooler Receptacle, Supplementary Protector CB1, And Power Switch 2-6. 115 Volts AC Cooler Receptacle, Supplementary Protector CB1, And Power Switch 805593-A 1 2 3 2-7. Gas Connections 805593-A 3 2 4 1 1 AC ...
Page 39 - Gas Connections; NGO’s
OM-290047 Page 29 � Complete Parts List is available at www.MillerWelds.com 5-9. Gas Connections 2-6. 115 Volts AC Cooler Receptacle, Supplementary Protector CB1, And Power Switch 805593-A 1 2 3 2-7. Gas Connections 805593-A 3 2 4 1 OM-222 Page 1 allen_wrench NGO’s tools/ flathead philips head wrenc...
Page 41 - Dynasty Stick Connections; Maxstar Stick Connections
OM-290047 Page 31 � Complete Parts List is available at www.MillerWelds.com 5-12. Dynasty Stick Connections A complete Parts List is available at www.MillerWelds.com 2-10. Dynasty Stick Connections 805596-A 2 1 3 Turn off power before makingconnections. � Connections shown are for Dynasty models. 1 ...
Page 44 - C. Dynasty 800 Models
OM-290047 Page 34 � Complete Parts List is available at www.MillerWelds.com C. Dynasty 800 Models Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommen-dations are for an individual branch circuit sized for the rated output and...
Page 46 - -15. Connecting Input Power For 400 Models And 800 CE Models; Connecting Input Power For 400 Models And 800 CE Models
OM-290047 Page 36 � Complete Parts List is available at www.MillerWelds.com 5-15. Connecting Input Power For 400 Models And 800 CE Models A. Connecting 3-Phase Input Power 2-11. Connecting Input Power For 400 Models And 800 CE Models L1 2 1 L2 L3 3 4 5 6 7 A. Connecting Three-Phase Input Power = GND...
Page 47 - B. Connecting Single-Phase Input Power
OM-290047 Page 37 � Complete Parts List is available at www.MillerWelds.com B. Connecting 1-Phase Input Power A complete Parts List is available at www.MillerWelds.com B. Connecting Single-Phase Input Power 1 6 5 4 2 7 6 L1 L2 1 =GND/PE Earth Ground 3 3 1 8 9 10 OM-222 Page 1 allen_wrench NGO’s tool...
Page 48 - -16. Connecting Input Power For 800 Models
OM-290047 Page 38 � Complete Parts List is available at www.MillerWelds.com 5-16. Connecting Input Power For 800 Models A. Connecting 3-Phase Input Power OM-222 Page 1 allen_wrench NGO’s tools/ flathead philips head wrench pliers knife heavy-duty workclamp light-duty workclamp wirecutter frontcutter...
Page 50 - A. Downloading Software Updates; B. Installing Software Updates; A. Reasons For Downloads Of Software Updates
OM-290047 Page 40 � Complete Parts List is available at www.MillerWelds.com 5-17. Software Updates A. Downloading Software Updates 1 2 Reasons To Download Software Updates: � To get the latest feature and softwareimprovements with future software updates. � For all circuit board replacements, asoftw...
Page 51 - SECTION 6 – DYNASTY OPERATION; Dynasty Controls; SECTION 3 DYNASTY OPERATION
OM-290047 Page 41 SECTION 6 – DYNASTY OPERATION 6-1. Dynasty Controls A complete Parts List is available at www.MillerWelds.com SECTION 3 DYNASTY OPERATION 273670-B 1 2 5 12 8 6 7 9 10 13 14 11 3 4 � For all front panel button controls: press button to turn on light and ena-ble normal function. � Gr...
Page 52 - Accessing Control Panel Menu; Accessing Control Panel Menu; Accessing Control Panel Menu
OM-290047 Page 42 6-2. Accessing Control Panel Menu 3-1. Accessing Control Panel Menu 273670-B 2 3 4 5 1 1 Memory Button Select Memory 1-9 (See Section 10). 2 Parameter Display 3 Setting Display 4 Amperage Adjustment Control Rotate amperage adjustment control to ad-just parameter setting. 5 Amperage...
Page 55 - Accessing User Setup Menu; MENU
OM-290047 Page 45 6-3. Accessing User Setup Menu A complete Parts List is available at www.MillerWelds.com 3-2. Accessing User Setup Menu 270536-A MENU 3 5 USER 2 1 4 1 Amperage Button 2 Gas/DIG Button 3 Parameter Display 4 Setting Display 5 Amperage Adjustment Control To access the User Functions, ...
Page 56 - AC Independent; A. AC Independent Waveshape
OM-290047 Page 46 6-4. AC Independent A. AC Independent Waveshape MENU 1 3 USER 5 4 2 270536-A 6 � AC Independent Expansion is available on DX models with SD expansion cardand on CE models with feature enablethrough the user menu (see Section 6-3). 1 Parameter Display/Voltmeter 2 Setting Display/Amm...
Page 57 - SECTION 7 – MAXSTAR OPERATION; SECTION 2 MAXSTAR OPERATION; Maxstar Controls
OM-290047 Page 47 SECTION 7 – MAXSTAR OPERATION 7-1. Maxstar Controls A complete Parts List is available at www.MillerWelds.com OM-275857 Page 6 SECTION 2 MAXSTAR OPERATION 275861-B / Ref. 803901-A 1 2 10 7 5 6 8 9 11 2-1. Maxstar Controls 12 4 3 � For all front panel button controls: press button t...
Page 61 - SECTION 8 – 28-PIN ADVANCED AUTOMATION OPERATION; SECTION 4 28-PIN ADVANCED AUTOMATION; Controls
OM-290047 Page 51 � Complete Parts List is available at www.MillerWelds.com SECTION 8 – 28-PIN ADVANCED AUTOMATION OPERATION 8-1. Controls A complete Parts List is available at www.MillerWelds.com SECTION 4 28-PIN ADVANCED AUTOMATION OPERATION 273670-B 1 2 4-1. Controls 6 5 3 4 � To activate 28-pin ...
Page 64 - Programmable TIG Start Parameters; B. Programmable TIG Start Amperage; C. Programmable Start Time; B. Programmable TIG Start Amperage
OM-290047 Page 54 � Complete Parts List is available at www.MillerWelds.com 8-4. Programmable TIG Start Parameters 1 Amperage Button 2 Encoder Control 3 Ammeter A. Off/On (Start Amperage And Time) 4-4. Programmable TIG Start Parameters 2 3 1 A. OFF/ON (Start Amperage And Time) Current (A) Start Time...
Page 65 - SECTION 9 – ADVANCED MENU FUNCTIONS; Accessing Tech Menu
OM-290047 Page 55 SECTION 9 – ADVANCED MENU FUNCTIONS 9-1. Accessing Tech Menu 1 Amperage Button 2 Gas/DIG Button Press and hold Amperage and Gas/Dig but-tons for approximately two seconds to scrollpast User Menu to Tech Menu. Use Gas/Digbutton to cycle through parameters that canbe set. 3 Parameter...
Page 66 - Sequencer And Weld Timer
OM-290047 Page 56 9-2. Sequencer And Weld Timer A complete Parts List is available at www.MillerWelds.com OM-270536 Page 23 Sequencer Control With Weld Timers ON This function is available while using the TIG process, but is disabled if a remote foot or fingertip con-trol is connected while in the R...
Page 67 - Output Control And Trigger Functions
OM-290047 Page 57 9-3. Output Control And Trigger Functions A. Remote (Standard), 2T, And 4TE Torch Trigger Operation Current (A) Preflow Initial Amps Initial Slope Final Slope Postflow Main Amps Final Amps R R P/H Maintained Switch Foot Or FingerRemote Control P/R P/R P/R P/R P/R P/R *P/R Time Stan...
Page 68 - B. 3T Specific Trigger Method
OM-290047 Page 58 B. 3T Specific Trigger Method 3T Trigger Operation * Arc can be extinguished at any time bypressing and releasing both initial and finalswitches, or by lifting the torch and breakingthe arc. P/R = Push and Release (in less than 3/4 ofa second) P/H = Push and Hold R = Release I = In...
Page 70 - D. On Trigger Operation; D. On Trigger Operation; D. On Trigger Operation
OM-290047 Page 60 D. On Trigger Operation ON A complete Parts List is available at www.MillerWelds.com D. On Trigger Operation Voltage (V) Current (A) Current (A) Touch Stick Lift Stick Touch Current Initial Amperage Initial Slope Main Amperage Touch Tungsten Lift TungstenSlightly Lift Tungsten Elec...
Page 71 - Lockout Functions; LOCK; OFF
OM-290047 Page 61 9-4. Lockout Functions 5-4. Lockout Functions LOCK CODE OFF 1 2 See Section 9-1 for information on how toaccess Lockout Functions. There are four (1-4) different lockout levels.Each successive level allows the operatormore flexibility. � Before activating lockout levels, be sure th...
Page 72 - Lockout Levels Defined
OM-290047 Page 62 9-5. Lockout Levels Defined Minimum Adjustability Degree of Adjustability Maximum Adjustability Lock Level 1 Lock Level 2 Lock Level 3 Lock Level 4 Adjustable Locked Adjustable Locked Adjustable Locked Adjustable Locked Panel Amps Panel Amps Panel Amps ± 10% Remote Amps (min-panel)...
Page 73 - SECTION 10 – MEMORY; SECTION 3 MEMORY; SECTION 4 MEMORY
OM-290047 Page 63 SECTION 10 – MEMORY 10-1. Memory (Program Storage Locations 1–9) OM-275857 Page 13 SECTION 3 MEMORY 3-1. Memory (Program Storage Locations 1-9) Memory Locations 1 9 AC DC TIG (HF or Lift) TIG (HF or Lift) Stick Stick And And And 2 3 2nd 3rd 1st 1 For Dynasty Models, each memory loc...
Page 74 - SECTION 11 – MAINTENANCE AND TROUBLESHOOTING; Blowing Out Inside of Unit; SECTION 6 MAINTENANCE AND TROUBLESHOOTING; Blowing Out Inside of Unit
OM-290047 Page 64 � Complete Parts List is available at www.MillerWelds.com SECTION 11 – MAINTENANCE AND TROUBLESHOOTING 11-1. Routine Maintenance Disconnect power before maintaining. � Maintain more often during severe conditions. � = Check ◇ = Change � = Clean � = Replace Every 3Months OM-249336 P...
Page 77 - SECTION 12 – ELECTRICAL DIAGRAMS
OM-290047 Page 67 SECTION 12 – ELECTRICAL DIAGRAMS 290105-B Figure 12-1. Dynasty 400 Circuit Diagram (Page 1 of 2)
Page 85 - SECTION 13 – HIGH FREQUENCY; 3-1. Welding Processes Requiring High Frequency; SECTION 1 HIGH FREQUENCY
OM-290047 Page 75 SECTION 13 – HIGH FREQUENCY 13-1. Welding Processes Requiring High Frequency OM- SECTION 1 HIGH FREQUENCY 1 TIG S-0694 13 9 8 7 1 2 4 5 6 3 10 11, 12 14 1 High-Frequency Voltage TIG – helps arc jump air gap between torchand workpiece and/or stabilize the arc. 13-2. Installation Sho...
Page 86 - 3-3. Recommended Installation To Reduce HF Interference
OM-290047 Page 76 13-3. Recommended Installation To Reduce HF Interference Best Practices Followed OM- 1 2 3 50 ft (15 m) 4 7 50 ft (15 m) 8 5 8 6 9 11 13 12 8 8 10 1 High-Frequency Source (welding powersource with built-in HF or separate HFunit) Ground metal machine case (clean paintfrom around hol...
Page 87 - A. Select Tungsten Electrode
OM-290047 Page 77 SECTION 14 – SELECTING AND PREPARING A TUNGSTEN FOR DC OR AC WELDING WITH INVERTER MACHINES 14-1. Selecting Tungsten Electrode Whenever possible and practical, use DC weld output instead of AC weld output. NOTICE – Wear clean gloves to prevent contamination of tungsten. A. Select T...
Page 88 - Welding With Inverter Machines
OM-290047 Page 78 14-2. Preparing Tungsten Electrode For DC Electrode Negative (DCEN) Welding Or AC Welding With Inverter Machines Wrong Tungsten Preparation — Radial Grinding Causes Wandering Arc OM- 1-1. Preparing Tungsten Electrode For DC Electrode Negative (DCEN) WeldingOr AC Welding With Invert...
Page 89 - SECTION 15 – TIG PROCEDURES; Lift-Arc And HF TIG Start Procedures; SECTION 5 TIG PROCEDURES; Lift-Arc And HF TIG Start Procedures; SECTION 5 TIG PROCEDURES; Lift-Arc And HF TIG Start Procedures
OM-290047 Page 79 SECTION 15 – TIG PROCEDURES 15-1. Lift-Arc And HF TIG Start Procedures Lift-Arc Start Method OM-275857 Page 17 SECTION 5 TIG PROCEDURES 5-1. Lift-Arc And HF TIG Start Procedures 1 2 “Touch” 1–2 Seconds OM-275857 Page 17 SECTION 5 TIG PROCEDURES 5-1. Lift-Arc And HF TIG Start Proced...
Page 91 - GEN
OM-290047 Page 81 15-3. General (GEN) Tungsten To Change Programmable TIG Starting Parameters OM-275857 Page 19 1 2 Current (A) Start Time Start Slope Time Preset Amperage Minimum S ta rt A m p e ra g e 3 GEN TUNG Available Parameter Settings OM-275857 Page 19 1 2 Current (A) Start Time Start Slope ...
Page 92 - SECTION 16 – STICK WELDING (SMAW) GUIDELINES; 6-1. Electrode And Amperage Selection Chart
OM-290047 Page 82 SECTION 16 – STICK WELDING (SMAW) GUIDELINES 16-1. Electrode And Amperage Selection Chart OM- 3/32 1/8 5/323/167/32 1/4 1/165/643/32 1/8 5/323/167/32 1/4 3/32 1/8 5/323/167/32 1/4 3/32 1/8 5/323/167/32 1/4 3/32 1/8 5/323/167/32 1/4 3/32 1/8 5/323/163/32 1/8 5/32 6010 & 6011 601...
Page 93 - Notes
Page 95 - ranties expressed or implied.
Effective January 1, 2022 (Equipment with a serial number preface of NC or newer) This limited warranty supersedes all previous Miller warranties and is exclusive with no other guarantees or war- ranties expressed or implied. LIMITED WARRANTY - Subject to the terms andconditions below, Miller Electr...
Page 96 - Miller Electric Mfg. LLC; Owner’s Record; Please complete and retain with your personal records.; For Service; Contact a DISTRIBUTOR or SERVICE AGENCY near you.
Miller Electric Mfg. LLC An Illinois Tool Works Company1635 West Spencer StreetAppleton, WI 54914 USA International Headquarters–USA USA Phone: 920-735-4505USA & Canada FAX: 920-735-4134International FAX: 920-735-4125 For International Locations Visitwww.MillerWelds.com ORIGINAL INSTRUCTIONS – P...