Page 2 - From Miller to You; Thank you; To locate your nearest
From Miller to You Mil_Thank1 2019 01 Miller is the first welding equipment manufacturer in theU. S. A. to be registered to theISO 9001 Quality System Standard. Working as hard as you do −every power source from Miller is backed by the mosthassle-free warranty in thebusiness. From Miller to You Than...
Page 3 - TABLE OF CONTENTS
TABLE OF CONTENTS SECTION 1 – SAFETY PRECAUTIONS – READ BEFORE USING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1-1 Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 5 - DECLARATION OF CONFORMITY; declares that the; Council Directives and Commission Regulations:; 014/30/EU Electromagnetic compatibility; David A. Werba
DECLARATION OF CONFORMITY for European Community (CE marked) products. MILLER Electric Mfg. LLC, 1635 Spencer Street, Appleton, WI 54914 U.S.A. declares that the product(s) identified in this declaration conform to the essential requirements and provisions of the stated Council Directive(s), Commi...
Page 6 - declares that; Electronic Equipment Regulations 2012
DECLARATION OF CONFORMITY For United Kingdom (UKCA marked) products. MILLER Electric Mfg. LLC, 1635 West Spencer Street, Appleton, WI 54914 U.S.A. declares that the product(s) identified in this declaration conform to the essential requirements and provisions of the stated Regulation(s) and Standard...
Page 7 - EMF DATA SHEET FOR ARC WELDING POWER SOURCE; Product/Apparatus Identification
EMF DATA SHEET FOR ARC WELDING POWER SOURCE Product/Apparatus Identification Product Stock Number MAXSTAR 280 DX (AUTO-LINE 208-575), CPS, CE 907539002 Compliance Information Summary Applicable regulation Directive 2014/35/EU Reference limits Directive 2013/35/EU, Recommendation 1999/519/EC Applicab...
Page 8 - SECTION 1 – SAFETY PRECAUTIONS – READ BEFORE USING; Symbol Usage; Arc Welding Hazards; ELECTRIC SHOCK can kill.
OM-253086 Page 1 SECTION 1 – SAFETY PRECAUTIONS – READ BEFORE USING Protect yourself and others from injury—read, follow, and save these important safety precautions and operating instructions. 1-1. Symbol Usage DANGER! – Indicates a hazardous situation which, if notavoided, will result in death or ...
Page 10 - Additional Hazards For Installation, Operation, And Maintenance
OM-253086 Page 3 CYLINDERS can explode if damaged. Compressed gas cylinders contain gas under highpressure. If damaged, a cylinder can explode.Since gas cylinders are normally part of the weld- ing process, be sure to treat them carefully. � Protect compressed gas cylinders from excessive heat, mech...
Page 11 - ARC WELDING can cause; California Proposition 65 Warnings; EMF Information
OM-253086 Page 4 ARC WELDING can cause interference. � Electromagnetic energy can interfere with sensitiveelectronic equipment such as microprocessors,computers, and computer-driven equipment such as robots. � Be sure all equipment in the welding area is electromagneticallycompatible. � To reduce po...
Page 12 - Symboles utilisés; Dangers relatifs au soudage à l’arc; UNE DÉCHARGE ÉLECTRIQUE peut
OM-253086 Page 5 SECTION 2 – CONSIGNES DE SÉCURITÉ - LIRE AVANT UTILISATION Pour écarter les risques de blessure pour vous-même et pour autrui — lire, appliquer et ranger en lieu sûr ces consignes relativesaux précautions de sécurité et au mode opératoire. 2-1. Symboles utilisés DANGER! – Indique un...
Page 14 - fonctionnement et la maintenance
OM-253086 Page 7 � Brancher le câble de masse sur la pièce le plus près possible dela zone de soudage pour éviter le transport du courant sur une lon-gue distance par des chemins inconnus éventuels en provoquantdes risques d’électrocution, d’étincelles et d’incendie. � Ne pas utiliser le poste de so...
Page 16 - Informations relatives aux CEM
OM-253086 Page 9 Safety in Welding, Cutting, and Allied Processes, CSA Standard W117.2 from Canadian Standards Association. Website: www. csa- group.org . Standard for Fire Prevention During Welding, Cutting, and Other HotWork, NFPA Standard 51B from National Fire Protection Association. Website: ww...
Page 17 - SECTION 3 – DEFINITIONS; Additional Safety Symbol Definitions; Additional Safety Symbols And Definitions; Additional Safety Symbols And Definitions; Additional Safety Symbols And Definitions; Additional Safety Symbols And Definitions; Additional Safety Symbols And Definitions
OM-253086 Page 10 � Complete Parts List is available at www.MillerWelds.com SECTION 3 – DEFINITIONS 3-1. Additional Safety Symbol Definitions � Some symbols are found only on CE products. Warning! Watch Out! There are possible hazards as shown by thesymbols. OM- 1-1. Additional Safety Symbols And De...
Page 19 - Miscellaneous Symbols And Definitions
OM-253086 Page 12 � Complete Parts List is available at www.MillerWelds.com OM- Do not use one handle to lift or support unit. Safe31 2017 04 Writer: If necessary, replace the word “handle” with “lift eye’. Drive rolls can injure fingers. Safe32 2012 05 Welding wire and drive parts are at welding vo...
Page 21 - SECTION 4 – SPECIFICATIONS; Serial Number And Rating Label Location; Specifications
OM-253086 Page 14 � Complete Parts List is available at www.MillerWelds.com SECTION 4 – SPECIFICATIONS 4-1. Serial Number And Rating Label Location The serial number and rating information for the power source is located on the top of the machine. Use the rating labels to determine inputpower requir...
Page 23 - A. Welding Power Source; Dimensions, Weights, And Mounting Options; B. Welding Power Source With Cart And Cooler; Dimensions, Weights, And Mounting Options
OM-253086 Page 16 � Complete Parts List is available at www.MillerWelds.com 4-5. Dimensions, Weights, And Mounting Options A. Welding Power Source A complete Parts List is available at www.MillerWelds.com OM-270536 Page 9 SECTION 2 INSTALLATION 2-1. Dimensions, Weights, And Mounting Options A. Weldi...
Page 24 - C. Mounting Options
OM-253086 Page 17 � Complete Parts List is available at www.MillerWelds.com C. Mounting Options A complete Parts List is available at www.MillerWelds.com OM-270536 Page 10 C. Mounting Options 805505-A 1 2 D F A B C E Dimensions A 15–7/16 in. (392 mm) B 9–19/32 in. (244 mm) Center-To-Center C 5/16 in...
Page 25 - Duty Cycle And Overheating; tp; A or V; Static Characteristics
OM-253086 Page 18 � Complete Parts List is available at www.MillerWelds.com 4-6. Duty Cycle And Overheating Duty Cycle is percentage of 10 minutes thatunit can weld at rated load without overheating. If unit overheats, output stops, a error mes-sage is displayed (see Section 9-4), and cool-ing fan r...
Page 26 - Environmental Specifications; B. Temperature Specifications; D. China EEP Hazardous Substance Information
OM-253086 Page 19 � Complete Parts List is available at www.MillerWelds.com 4-8. Environmental Specifications A. IP Rating IP Rating IP23 This equipment is designed for outdoor use. B. Temperature Specifications Operating Temperature Range * Storage/Transportation Temperature Range 14 to 104°F (-10 ...
Page 27 - E. EU Ecodesign Information
OM-253086 Page 20 � Complete Parts List is available at www.MillerWelds.com E. EU Ecodesign Information Model Input Minimum Power Source Efficiency Maximum Idle State Power Consumption Maxstar 280, 280 DX 400V Three Phase 85.5% 13.7 W Maxstar 280, 280 DX 230V Single Phase 83.5% 12.4 W OM- 1-1. Addit...
Page 28 - SECTION 5 – INSTALLATION; Selecting A Location; Selecting a Location
OM-253086 Page 21 � Complete Parts List is available at www.MillerWelds.com SECTION 5 – INSTALLATION 5-1. Selecting A Location Movement OM-231 242 Page 2 1-1. Selecting a Location 3 18 in. (460 mm) 18 in. (460 mm) 1 2 3 18 in. (460 mm) 18 in. (460 mm) Location And Airflow 3 1 18 in. (460 mm) 18 in. ...
Page 29 - Weld Output Terminals; Dynasty Front Panel
OM-253086 Page 22 � Complete Parts List is available at www.MillerWelds.com 5-2. Selecting Cable Sizes 1 NOTICE – The Total Cable Length in Weld Circuit (see table below) is the combined length of both weld cables. For example, if the power source is 100 ft (30 m) from the workpiece, the total cable...
Page 30 - Connections; NGO’s
OM-253086 Page 23 � Complete Parts List is available at www.MillerWelds.com 5-4. Connections Front Panel 1 7 2 8 Rear Panel 805496-B 3 4 5 6 OM-222 Page 1 allen_wrench NGO’s tools/ flathead philips head wrench pliers knife heavy-duty workclamp light-duty workclamp wirecutter frontcutter allen_set ne...
Page 31 - Cooler Connections
OM-253086 Page 24 � Complete Parts List is available at www.MillerWelds.com 5-5. Cooler Connections OM-222 Page 1 allen_wrench NGO’s tools/ flathead philips head wrench pliers knife heavy-duty workclamp light-duty workclamp wirecutter frontcutter allen_set needlenose steelbrush nutdriver chippingham...
Page 32 - A. Electrical Service Guide For Three-Phase Operation
OM-253086 Page 25 � Complete Parts List is available at www.MillerWelds.com 5-6. Electrical Service Guide (Maxstar) A. Electrical Service Guide For Three-Phase Operation Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommen-dat...
Page 33 - B. Electrical Service Guide For Single-Phase Operation
OM-253086 Page 26 � Complete Parts List is available at www.MillerWelds.com B. Electrical Service Guide For Single-Phase Operation Failure to follow these electrical service guide recommendations could create an electric shock or fire hazard. These recommen-dations are for an individual branch circu...
Page 34 - Connecting 3-Phase Input Power; Connecting Three-Phase Input Power
OM-253086 Page 27 � Complete Parts List is available at www.MillerWelds.com 5-7. Connecting 3-Phase Input Power A complete Parts List is available at www.MillerWelds.com OM-253086 Page 5 = GND/PE Earth Ground L1 2 1 L2 L3 3 3 4 5 6 7 2-3. Connecting Three-Phase Input Power OM-222 Page 1 allen_wrench...
Page 35 - Connecting 1-Phase Input Power; Connecting Single-Phase Input Power
OM-253086 Page 28 � Complete Parts List is available at www.MillerWelds.com 5-8. Connecting 1-Phase Input Power A complete Parts List is available at www.MillerWelds.com OM-253086 Page 6 2-4. Connecting Single-Phase Input Power 1 6 5 4 2 7 6 L1 L2 1 =GND/PE Earth Ground 3 3 1 8 9 10 OM-222 Page 1 al...
Page 36 - Remote 14 Receptacle Information; A. Software Installation
OM-253086 Page 29 � Complete Parts List is available at www.MillerWelds.com 5-9. Remote 14 Receptacle Information A complete Parts List is available at www.MillerWelds.com OM-270536 Page 15 2-6. Remote 14 Receptacle Information 805 497-A A J B K I C L N H D M G E F A. Software Installation 805496-A ...
Page 37 - A. Downloading Software Updates; B. Installing Software Updates
OM-253086 Page 30 � Complete Parts List is available at www.MillerWelds.com 5-11. Software Updates A. Downloading Software Updates 1 2 Reasons To Download Software Updates: � To get the latest feature and softwareimprovements with future software updates. � For all circuit board replacements, asoftw...
Page 38 - SECTION 6 – MAXSTAR 280 OPERATION; A. AC Independent Waveshape; MENU; SECTION 5 MAXSTAR 280 OPERATION
OM-253086 Page 31 � Complete Parts List is available at www.MillerWelds.com SECTION 6 – MAXSTAR 280 OPERATION 6-1. Maxstar 280 Controls A complete Parts List is available at www.MillerWelds.com OM-253086 Page 16 A. AC Independent Waveshape MENU 3 4 5 USER 1 6 280589-A 2 SECTION 5 MAXSTAR 280 OPERATI...
Page 39 - Accessing Control Panel Menu: DC TIG HF And Lift-Arc; Accessing Control Panel Menu: DC TIG HF And Lift Arc
OM-253086 Page 32 � Complete Parts List is available at www.MillerWelds.com 6-2. Accessing Control Panel Menu: DC TIG HF And Lift-Arc A complete Parts List is available at www.MillerWelds.com OM-253086 Page 17 HF START Schedule 1 Schedule 2 LIFT ARC 5-2. Accessing Control Panel Menu: DC TIG HF And L...
Page 40 - Accessing Control Panel Menu: DC Stick
OM-253086 Page 33 � Complete Parts List is available at www.MillerWelds.com 6-3. Accessing Control Panel Menu: DC Stick A complete Parts List is available at www.MillerWelds.com OM-253086 Page 18 HF START Schedule 1 Schedule 2 LIFT ARC 5-3. Accessing Control Panel Menu: DC Stick 1 110A 2 3 4 Or 2472...
Page 41 - Accessing User Setup Menu: DC TIG And Lift-Arc; Accessing User Setup Menu: DC TIG HF And Lift-Arc
OM-253086 Page 34 � Complete Parts List is available at www.MillerWelds.com 6-4. Accessing User Setup Menu: DC TIG And Lift-Arc A complete Parts List is available at www.MillerWelds.com OM-253086 Page 19 HF START Schedule 1 Schedule 2 LIFT ARC HF START Schedule 1 Schedule 2 LIFT ARC 5-4. Accessing U...
Page 42 - Accessing User Setup Menu: AC And DC Stick; Accessing User Setup Menu: DC Stick
OM-253086 Page 35 � Complete Parts List is available at www.MillerWelds.com 6-5. Accessing User Setup Menu: AC And DC Stick A complete Parts List is available at www.MillerWelds.com OM-253086 Page 20 HF START Schedule 1 Schedule 2 LIFT ARC 5-5. Accessing User Setup Menu: DC Stick 1 2 3 4 MENU USER O...
Page 43 - SECTION 7 – MAXSTAR 280 DX OPERATION; SECTION 6 MAXSTAR 280 DX OPERATION; Maxstar 280 DX Controls
OM-253086 Page 36 � Complete Parts List is available at www.MillerWelds.com SECTION 7 – MAXSTAR 280 DX OPERATION 7-1. Maxstar 280 DX Controls A complete Parts List is available at www.MillerWelds.com OM-253086 Page 21 SECTION 6 MAXSTAR 280 DX OPERATION 6-1. Maxstar 280 DX Controls 2 5 4 6 1 247216-D...
Page 44 - Accessing Control Panel Menu; Accessing Control Panel Menu; Accessing Control Panel Menu
OM-253086 Page 37 � Complete Parts List is available at www.MillerWelds.com 7-2. Accessing Control Panel Menu A complete Parts List is available at www.MillerWelds.com OM-253086 Page 22 6-2. Accessing Control Panel Menu 247216-D 150A 1 2 3 4 1 Amperage Button 2 Parameter Display 3 Setting Display 4 ...
Page 46 - Accessing User Setup Menu
OM-253086 Page 39 � Complete Parts List is available at www.MillerWelds.com 7-3. Accessing User Setup Menu A complete Parts List is available at www.MillerWelds.com OM-253086 Page 23 6-3. Accessing User Setup Menu 247216-D MENU 1 2 3 4 USER 5 1 Amperage Button 2 Gas/Dig Button 3 Parameter Display 4 ...
Page 47 - SECTION 8 – ADVANCED MENU FUNCTIONS; Accessing Tech Menu For Maxstar 280 Models
OM-253086 Page 40 � Complete Parts List is available at www.MillerWelds.com SECTION 8 – ADVANCED MENU FUNCTIONS 8-1. Accessing Tech Menu For Maxstar 280 Models Hold for Setup 271723-B 2 3 4 1 1 Menu Button Press and hold Menu button for approxi-mately four seconds to scroll past User Menuto Tech Men...
Page 48 - Accessing Tech Menu For Maxstar 280DX Models
OM-253086 Page 41 � Complete Parts List is available at www.MillerWelds.com 8-2. Accessing Tech Menu For Maxstar 280DX Models 247216-D 3 4 5 1 2 1 Amperage Button 2 Gas/Dig Button Press and hold Amperage and Gas/Dig but-tons for approximately two seconds to scrollpast User Menu to Tech Menu. Use Gas...
Page 49 - Sequencer And Weld Timer For DX Models
OM-253086 Page 42 � Complete Parts List is available at www.MillerWelds.com Parameter/Setting Display Description [ARC] [T/CY] Arc Timer: Monitors hours, minutes, and cycles of valid arc on. To view, rotate amperage adjustment con- trol. To reset, rotate amperage adjustment control until [RESET] [YE...
Page 50 - Output Control And Trigger Functions For DX Models
OM-253086 Page 43 � Complete Parts List is available at www.MillerWelds.com 8-4. Output Control And Trigger Functions For DX Models A. Remote (Standard), 2T, And 4TE Torch Trigger Operation Current (A) Preflow Initial Amps Initial Slope Final Slope Postflow Main Amps Final Amps R R P/H Maintained Sw...
Page 51 - B. 3T Specific Trigger Method
OM-253086 Page 44 � Complete Parts List is available at www.MillerWelds.com B. 3T Specific Trigger Method 3T Trigger Operation * Arc can be extinguished at any time bypressing and releasing both initial and finalswitches, or by lifting the torch and breakingthe arc. P/R = Push and Release (in less t...
Page 53 - Lockout Functions; Lockout Levels Defined
OM-253086 Page 46 � Complete Parts List is available at www.MillerWelds.com 8-5. Lockout Functions 247216-D 1 2 See Section 8-2 for information on how toaccess Lockout Functions. There are four (1-4) different lockout levels.Each successive level allows the operatormore flexibility. � Before activat...
Page 54 - SECTION 9 – MAINTENANCE AND TROUBLESHOOTING; Routine Maintenance; Blowing Out Inside of Unit; SECTION 9 MAINTENANCE AND TROUBLESHOOTING; Blowing Out Inside of Unit; SECTION 12 MAINTENANCE AND TROUBLESHOOTING
OM-253086 Page 47 � Complete Parts List is available at www.MillerWelds.com SECTION 9 – MAINTENANCE AND TROUBLESHOOTING 9-1. Routine Maintenance Disconnect power before maintaining. � Maintain more often during severe conditions. A. Welding Power Source � = Check ◇ = Change � = Clean � = Replace Eve...
Page 55 - Blowing Out Inside Of Unit; Coolant Maintenance
OM-253086 Page 48 � Complete Parts List is available at www.MillerWelds.com 9-2. Blowing Out Inside Of Unit A complete Parts List is available at www.MillerWelds.com OM-270536 Page 42 SECTION 9 MAINTENANCE AND TROUBLESHOOTING Every6Months :During heavy service, clean monthly. ! Do not remove case wh...
Page 56 - Voltmeter/Ammeter Display Messages
OM-253086 Page 49 � Complete Parts List is available at www.MillerWelds.com 9-4. Voltmeter/Ammeter Display Messages � All directions are in reference to the front of the unit. All circuitry referred to is located inside the unit. Message Type Display Message Description Release Trigger [RELE] [ASE] ...
Page 57 - Troubleshooting Table
OM-253086 Page 50 � Complete Parts List is available at www.MillerWelds.com 9-5. Troubleshooting Table Trouble Remedy No weld output; unit completelyinoperative. Place line disconnect switch in On position (see Section or 5-7 or 5-8). Check and replace line fuse(s), if necessary, or reset circuit br...
Page 58 - SECTION 10 – PARTS LIST
OM-253086 Page 51 � Complete Parts List is available at www.MillerWelds.com SECTION 10 – PARTS LIST 10-1. Recommended Spare Parts Recommended Spare Parts Dia. Mkgs. Part No. Description Quantity 239494 Screen, Filter Lp Cyl 100 x 100 x 0.0045 SST A 1 043810 Coolant 1 +When ordering a component origi...
Page 59 - SECTION 11 – ELECTRICAL DIAGRAMS; Figure 11-1. Circuit Diagram For Maxstar 280
OM-253086 Page 52 SECTION 11 – ELECTRICAL DIAGRAMS 255981-J Figure 11-1. Circuit Diagram For Maxstar 280
Page 60 - SECTION 12 – HIGH FREQUENCY; 2-1. Welding Processes Requiring High Frequency; SECTION 1 HIGH FREQUENCY
OM-253086 Page 53 SECTION 12 – HIGH FREQUENCY 12-1. Welding Processes Requiring High Frequency OM- SECTION 1 HIGH FREQUENCY 1 TIG S-0694 13 9 8 7 1 2 4 5 6 3 10 11, 12 14 1 High-Frequency Voltage TIG – helps arc jump air gap between torchand workpiece and/or stabilize the arc. 12-2. Installation Sho...
Page 61 - 2-3. Recommended Installation To Reduce HF Interference
OM-253086 Page 54 12-3. Recommended Installation To Reduce HF Interference Best Practices Followed OM- 1 2 3 50 ft (15 m) 4 7 50 ft (15 m) 8 5 8 6 9 11 13 12 8 8 10 1 High-Frequency Source (welding powersource with built-in HF or separate HFunit) Ground metal machine case (clean paintfrom around hol...
Page 62 - SECTION 13 – TIG PROCEDURES; Lift-Arc And HF TIG Start Procedures; SECTION 5 TIG PROCEDURES; Lift-Arc And HF TIG Start Procedures; SECTION 5 TIG PROCEDURES; Lift-Arc And HF TIG Start Procedures
OM-253086 Page 55 SECTION 13 – TIG PROCEDURES 13-1. Lift-Arc And HF TIG Start Procedures Lift-Arc Start Method OM-275857 Page 17 SECTION 5 TIG PROCEDURES 5-1. Lift-Arc And HF TIG Start Procedures 1 2 “Touch” 1–2 Seconds OM-275857 Page 17 SECTION 5 TIG PROCEDURES 5-1. Lift-Arc And HF TIG Start Proced...
Page 64 - GEN
OM-253086 Page 57 13-3. General (GEN) Tungsten To Change Programmable TIG Starting Parameters 247216-D 1 2 3 Available Parameter Settings OM-275857 Page 19 1 2 Current (A) Start Time Start Slope Time Preset Amperage Minimum S ta rt A m p e ra g e 3 GEN TUNG 1 Parameter Display 2 Amperage Adjustment ...
Page 65 - A. Select Tungsten Electrode
OM-253086 Page 58 SECTION 14 – SELECTING AND PREPARING A TUNGSTEN FOR DC OR AC WELDING WITH INVERTER MACHINES 14-1. Selecting Tungsten Electrode Whenever possible and practical, use DC weld output instead of AC weld output. NOTICE – Wear clean gloves to prevent contamination of tungsten. A. Select T...
Page 66 - Welding With Inverter Machines
OM-253086 Page 59 14-2. Preparing Tungsten Electrode For DC Electrode Negative (DCEN) Welding Or AC Welding With Inverter Machines Wrong Tungsten Preparation — Radial Grinding Causes Wandering Arc OM- 1-1. Preparing Tungsten Electrode For DC Electrode Negative (DCEN) WeldingOr AC Welding With Invert...
Page 67 - SECTION 15 – STICK WELDING (SMAW) GUIDELINES; 5-1. Electrode And Amperage Selection Chart
OM-253086 Page 60 SECTION 15 – STICK WELDING (SMAW) GUIDELINES 15-1. Electrode And Amperage Selection Chart OM- 3/32 1/8 5/323/167/32 1/4 1/165/643/32 1/8 5/323/167/32 1/4 3/32 1/8 5/323/167/32 1/4 3/32 1/8 5/323/167/32 1/4 3/32 1/8 5/323/167/32 1/4 3/32 1/8 5/323/163/32 1/8 5/32 6010 & 6011 601...
Page 68 - Notes
Page 71 - ranties expressed or implied.
Effective January 1, 2023 (Equipment with a serial number preface of ND or newer) This limited warranty supersedes all previous Miller warranties and is exclusive with no other guarantees or war- ranties expressed or implied. LIMITED WARRANTY - Subject to the terms andconditions below, Miller Electr...
Page 72 - Miller Electric Mfg. LLC; Owner’s Record; Please complete and retain with your personal records.; For Service; Contact a DISTRIBUTOR or SERVICE AGENCY near you.
Miller Electric Mfg. LLC An Illinois Tool Works Company1635 West Spencer StreetAppleton, WI 54914 USA International Headquarters–USA USA Phone: 920-735-4505USA & Canada FAX: 920-735-4134International FAX: 920-735-4125 For International Locations Visitwww.MillerWelds.com ORIGINAL INSTRUCTIONS – P...