Lincoln Electric 10708 - Manual

Lincoln Electric 10708

Lincoln Electric 10708 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
Page: / 50

Table of Contents:

  • Page 2 – SAFETY; WARNING; CALIFORNIA PROPOSITION 65 WARNINGS; The Above For Diesel Engines
  • Page 3 – ii
  • Page 4 – iii
  • Page 5 – iv; PRÉCAUTIONS DE SÛRETÉ
  • Page 6 – Thank You; Please Examine Carton and Equipment For Damage Immediately
  • Page 7 – TABLE OF CONTENTS
  • Page 8 – vii
  • Page 9 – INSTALLATION; INPUT - GASOLINE ENGINE
  • Page 10 – 5AMP for Battery Charging Circuit
  • Page 11 – ADDITIONAL SAFETY PRECAUTIONS; Design capacity of trailer vs. weight of Lincoln; SAFETY PRECAUTIONS; LOCATION AND VENTILATION; RANGER 305G machines cannot be stacked.; S e e a dd i t i o n a l w a r n i n g i n fo r m a t i o n a t
  • Page 12 – • Wipe up spilled fuel and allow fumes to clear; USE GASOLINE FUEL ONLY; • F i l l t h e f u e l t a n k w i t h c l e a n , f r e s h f u e l . T h e; CAUTION
  • Page 13 – ELECTRICAL CONNECTIONS; MACHINE GROUNDING; • Be grounded to the frame of the welder using a; WELDING TERMINALS; CABLE INSTALLATION; The gasoline engine must be OFF to install welding; • Loose connections will cause the output termi-; TOTAL COMBINED LENGTH OF; Cable Length
  • Page 14 – • Do not cross the welding cables at the output; AUXILIARY POWER RECEPTACLES; The 240 V receptacle has two 120 V circuits,; STANDBY POWER CONNECTIONS; • I n s t a l l t h e d o u b l e - p o l e , d o u b l e - t h r o w s w i t c h
  • Page 15 – CONNECTION OF RANGER 305G TO PREMISES WIRING
  • Page 16 – Connection of the LN-25 to the RANGER 305G
  • Page 17 – OPERATION; GENERAL DESCRIPTION; ENGINE OPERATION
  • Page 18 – The CONTROL dial; DIGITAL OUTPUT METERS
  • Page 19 – START PUSH BUTTON
  • Page 20 – • The engine will run at high idle speed for approxi-; NOTE; : When starting a RANGER 305G for the first; STOPPING; A fuel shut off valve is not required on the; WELDER OPERATION; Stick Welding; TYPICAL RANGER 305G FUEL CONSUMPTION; Running Time for
  • Page 21 – TIG Welding; The ARC CONTROL is not active in the TIG mode.; TYPICAL CURRENT RANGES
  • Page 22 – ARC GOUGING
  • Page 23 – ACCESSORIES; K1745-1 SINGLE GAS CYLINDER HOLDER; Mounts inside exhaust pipe.; REMOTE; 20V duplex receptacle. Each receptacle of the GFCI; K802-N POWER PLUG KIT
  • Page 24 – MAINTENANCE; KOHLER ENGINE; Have qualified personnel do all maintenance
  • Page 25 – Engine Oil Change; Engine; Air Pre-cleaner Service
  • Page 26 – AIR FILTER PAPER ELEMENT; SPARK PLUG; Spark Plug Service
  • Page 27 – FUEL FILTER; • Check the fuel filter for water accumulation or sedi-; ENGINE ADJUSTMENT; OVERSPEED IS HAZARDOUS; Clean every 100 hours.; MUFFLER MAY BE HOT
  • Page 28 – Welder/Generator Maintenance; Store the RANGER 305G in clean, dry; BRUSH REMOVAL AND REPLACEMENT:
  • Page 29 – TROUBLESHOOTING; Local Lincoln Authorized Field Service Facility; for technical troubleshooting assistance before you proceed.; Step 3. RECOMMENDED COURSE OF ACTION; HOW TO USE TROUBLESHOOTING GUIDE
  • Page 30 – PROBLEMS; C o n t a c t y o u r l o c a l L i n c o l n
  • Page 31 – Observe all Safety Guidelines detailed throughout this manual; P o o r w o r k l e a d c o n n e c t i o n t o
  • Page 33 – M a k e s u r e t h e M O D E s e l e c t o r; Contact
  • Page 34 – DIAGRAMS
  • Page 39 – ARN; INE
  • Page 45 – RANGER 305G WIRING DIAGRAM
  • Page 46 – DIMENSION
  • Page 47 – NOTES
  • Page 48 – ÇÃ
Loading the manual

Ranger 305 G

OPERATOR’S MANUAL

IM674

August, 2001

Safety Depends on You

Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However, your
overall safety can be increased by
proper installation ... and thought-
f u l o p e r a t i o n o n y o u r p a r t .

D O

N O T I N S T A L L , O P E R A T E O R
R E P A I R T H I S E Q U I P M E N T
W I T H O U T R E A D I N G T H I S
M A N U A L A N D T H E S A F E T Y
P R E C A U T I O N S C O N T A I N E D
T H R O U G H O U T .

A n d , m o s t

importantly, think before you act
and be careful.

For use with machines having Code Numbers:

10708

• Sales and Service through Subsidiaries and Distributors Worldwide •

Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com

• World's Leader in Welding and Cutting Products •

Date of Purchase:
Serial Number:
Code Number:
Model:
Where Purchased:

Copyright © 2001 Lincoln Global Inc.

RETURN TO MAIN MENU

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SAFETY; WARNING; CALIFORNIA PROPOSITION 65 WARNINGS; The Above For Diesel Engines

FOR ENGINEpowered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors....

Page 3 - ii

ii SAFETY ii ARC RAYS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks andthe rays of the arc when welding or observingopen arc welding. Headshield and filter lensshould conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable...

Page 4 - iii

FOR ELECTRICALLYpowered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working onthe equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’srecommendations. 8.c. Ground the equipment in ac...