Page 4 - Other
4 1 4 2 3 1.1. 4 2.1. 12 9 11 10 14 20 8 18 15 16 17 19 13 5 6 7 3 Other - Confirmation tone for touch screen operation can be selected to on or off. - Can be desk mounted or wall mounted according to the design. - Programmable time for display illumination All important weather information appears ...
Page 7 - Installation and Commissioning of sensors
7 ensures optimum reception in the initialization phase. If the signal from the sensor is unable to be received within this time, then the reception is affected and should be improved by re-positioning the sensor. The external temperature and humidity sensors should be addressed according to section...
Page 8 - or mm and displayed.; sensor
8 electronics. The upper part of the housing can now be placed so that the solar cell is on the same side as the magnet, with the electronic part directly opposite it, with the three catches fitting neatly into the holding devices in the lower part. Finally turn the upper part gently anti-clockwise ...
Page 9 - Basic settings, Configuration
9 2.3.8 Information on the storage of solar cell powered outdoor sensors These sensors receive their operating voltage from a solar cell that charges an internal battery to provide power for periods of darkness and bad weather. If one of these sensors is out of action for some time and does not rece...
Page 11 - Illumination time for AC adaptor operation; A setting; Illumination time for battery operation; exclusively; Setting the temperature display units; and the lower touch screen field will change to the following form:
11 Illumination time for AC adaptor operation The illumination time for AC adaptor operation (“line”) is displayed in the “LIGHT” field (touch screen field 1). A setting here is only meaningful when the weather station is powered by means of the AC adaptor power supply. The time displayed shows in h...
Page 12 - Setting the rainfall display units
12 Calibration of the rainfall reading indicator The rainfall measuring system is delivered with a very high accuracy, so that normally no calibration is required. A calibration only becomes necessary when very high accuracy is required for professional use or for special purposes. Before starting t...
Page 13 - The associated display will now flash:; Setting the time function; The time of day display will now flash:; and the lower touch screen field will change to the following
13 Setting the air pressure display units The display units for air pressure are shown in touch screen field 11 on the right hand side next to the air pressure value. The factory setting is hPa. - By touching field 11 the display units can be switched between hPa, mmHg or inHg. Keypad beep on/off - ...
Page 14 - The seconds are automatically set to zero.; Setting the day and the date; The date display will now flash:; Sensor administration; if deviating from address 7. If an address is changed
14 4 1 3 2 The seconds are automatically set to zero. - The WWVB reception can also be switched on or off by means of the “WWVB” touch screen field as long as the time is flashing (radio mast symbol on or off respectively). - In addition, it now possible to select the display format for the time, da...
Page 17 - The following particular features should be noted:
17 4. Here, the “Graph” symbol shows that the trend display for the wind direction has been selected in the history field. It only appears if it has previously been selected (see 3.2.6.:“History”). The trend can be displayed in km/h, m/s, mph or knots. However, if Beaufort or degrees have been chose...
Page 18 - the; “Graph” symbol; Sunny Bright Cloudy Rainy; display; The request “SELECT ” then appears.
18 The maximum values the last 8 days are displayed. 3. Here, the “Graph” symbol shows that the trend display for the air pressure has been selected in the history field. It only appears if it has previously been selected (see section on “History ”). If the air pressure history is active, then the t...
Page 21 - You can return to the normal display by pressing the “END ” key.
21 Example for the display of minimum values. Display min/max values - The display mode is selected by touching the appropriate field “MAX” (field 27) or “MIN” (field 25). The particular touch screen field activated (MIN or MAX) will be faded out. Both titles are only visible in normal display mode....
Page 22 - High or low temperature for all sensors; Wake-up times are only shown in
22 3.4. Programming mode (entering alarm values) You can program the weather station so that an audible-visible alarm occurs when certain minimum or maximum values are reached. As well as this, daily wake-up times can be programmed so that the weather station can also be used as an alarm clock or an...
Page 23 - the MIN/MAX alarm values; Pressing the “END” key terminates the input and stores the value.
23 3.4.2. Setting/Resetting the MIN/MAX alarm values - After activating one of the alarm value displays (MIN or MAX), touch the value field for which the alarm value is to be set. - The value will flash and the lower control field will change to the following form: - The flashing value can be adjust...
Page 24 - The alarm is reset using the “RESET” key.
24 3.4.4. Alarm initiation, Alarm reset - If the measured value exceeds or falls below one of the set alarm values, the display will go off and the alarm value in question together with the text “ALARM” and the appropriate high or low deviation (MAX or MIN) will be displayed. At the same time, an in...
Page 26 - Repeater for range increase
26 Rotate the weather station a little if required, and if reception is bad, locate it away from electric motors, electrical machines, televisions, computer monitors and large metal surfaces. To facilitate commissioning you can initially locate the sensors in the vicinity of the base unit (at least ...
Page 29 - WARRANTY INFORMATION; Crosse Technology, Ltd’s authorized service center.; edition
29 WARRANTY INFORMATION La Crosse Technology, Ltd provides a 1-year limited warranty on this product against manufacturing defects in materials and workmanship. This limited warranty begins on the original date of purchase, is valid only on products purchased and used in North America and only to th...