Honeywell Y460A2003- Manual

Honeywell Y460A2003

Honeywell Y460A2003– Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
Page: / 6

Table of Contents:

  • Page 2 – RECYCLING NOTICE; MOUNT THE SUBBASE; Wire the Subbase
  • Page 3 – MOUNT YOUR THERMOSTAT
  • Page 4 – SET THE TEMPERATURE; Set Subbase Switch; CHECK OUT THE SYSTEM; Heating; CAUTION; WARRANTY
Loading the manual

® U.S. Registered Trademark
Copyright © 1999 Honeywell Inc. • •All Rights Reserved

INSTALLATION MANUAL

69- 1358

The Round

®

Creative Series

Y460A2003 Thermostat

The Y460A2003 Thermostat is for 15 to 30 Vac control
of gas- or oil-fueled warm air, steam or hot water
heating/electric cooling systems.

Your Y460A Thermostat

Follow these instructions step-by-step for proper
installation of your Honeywell thermostat. It is
recommended that as you read, understand and
complete each step, you check

it off with a pencil

or pen.

1 PREPARE FOR INSTALLATION

Assemble the following required tools:
Flat-bladed screwdriver; hand or power drill with
3/16 in. (4.8 mm) drill bit; wire cutter/stripper or sharp
knife; bubble level or plumb bob and line.

IMPORTANT:

For cooling systems, do not operate cooling if
outdoor temperature is below 50

°

F (10

°

C).

Test your heating and/or cooling systems to be sure
they are working, especially if they have been
inoperative for any length of time. If either system
does not work, contact your local heating/air
conditioning dealer for assistance.

IMPORTANT:

Turn off power to the system at the main fuse
or circuit breaker panel. Most buildings have a
separate switch box or circuit breaker for dis-
connecting power to the furnace.

2 UNPACK YOUR THERMOSTAT

Carefully unpack your new thermostat.

Remove and discard the shipping wrap; be sure to
save the screws and the instructions.

Remove the thermostat cover and set it aside to use
later.

Remove the red plastic insert that holds the mercury
switch in place.

3 REMOVE YOUR OLD
THERMOSTAT

Remove the cover of the old thermostat. If the cover
does not snap off when pulled firmly from the
bottom, look for screw(s) to loosen to unlock the
cover.

Before removing
the old thermostat
from the wall, look
at it carefully to
locate the heat
anticipator
adjustment
mechanism. Look
at the illustration to
help you recognize
the heat
anticipator. Make a
note here ______________ of that anticipator
setting for use in Step 7. The heat anticipator pointer,
if adjustable, will be set at one of a series of numbers
representing the electrical current rating of the
primary control in your furnace: .2, .4, .8, etc or 0.2,
0.4, 0.8, etc. If no heat anticipator/indication is
showing, go on to the next step.

Loosen screw(s) holding the thermostat base to the
subbase or wall and lift it away.

FLAT BLADE
SCREWDRIVER

HAND OR POWER
DRILL WITH 1/16 INCH
DRILL BIT, IF NEEDED TO
DRILL HOLES IN WALL

WIRE CUTTER/STRIPPER OR SHARP
KNIFE, IF NEEDED TO STRIP WIRES

MASKING TAPE, IF NEEDED
TO LABEL WIRES AS THEY
ARE DISCONNECTED FROM
OLD THERMOSTAT

SPIRIT LEVEL OR PLUMB BOB AND LINE TO LEVEL
THERMOSTAT FOR ACCURATE OPERATION

M 835

M6115

BULB
SWITCH

ANTICIPATOR
SCALE

ANTICIPATOR
SETTING LEVER

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Honeywell Y460A2003

Summary

Page 2 - RECYCLING NOTICE; MOUNT THE SUBBASE; Wire the Subbase

THE ROUND® CREATIVE SERIES Y460A2003 THERMOSTAT 69-1358 2 ❑ Disconnect wires from the old thermostat or subbase. Wrap the wires around a pencil or other object, as shown, to prevent them from falling back into the wall opening. NOTE: As you disconnect each wire, use masking tape to tape the end and ...

Page 3 - MOUNT YOUR THERMOSTAT

THE ROUND® CREATIVE SERIES Y460A2003 THERMOSTAT 3 69-1358 ❑ Firmly tighten the screws. ❑ Push the excess wire back into the wall. ❑ Plug the hole with nonflammable insulation to prevent drafts from affecting the thermostat operation. Y460A for heating/cooling system using separate RC-RH terminals. I...

Page 4 - SET THE TEMPERATURE; Set Subbase Switch; CHECK OUT THE SYSTEM; Heating; CAUTION; WARRANTY

THE ROUND® CREATIVE SERIES Y460A2003 THERMOSTAT 69-1358 4 — Let the system operate through the ammeter for at least one minute before taking a reading. Record the reading here ______________ . — Reconnect the W wire to the W terminal. ❑ Move the heat anticipator indicator to match the number you rec...