Honeywell W8600F- User Manual
Honeywell W8600F– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Mounting; Remove the template and drill the holes.; RETURN AIR DUCT
- Page 3 – IMPORTANT; WARNING; Fig. 6. Placing shorting bar on power supply for
- Page 4 – Automation and Control Solutions; SYSTEM CHECKOUT; Table 3. W8600F Troubleshooting Information.
® U.S. Registered Trademark
Copyright © 2002 Honeywell International Inc. •
• All Rights Reserved
INSTALLATION INSTRUCTIONS
69-1200-2
W8600F Air Cleaner Monitor
APPLICATION
The W8600F Air Cleaner Monitor is an option available
for use with the F50F and F52F Honeywell Electronic Air
Cleaners (EAC). The series two F50F and F52F require
a solid state power supply that is compatible with the
W8600F driver board. Any series one F50E, F or F52F
can be upgraded to use the W8600F when the power
supply is replaced and the driver board (included in
W8600F kit) is installed.
The W8600F function indicator panel has four liquid
crystal display (LCD) arrowheads that point to ON,
BATTERY, SERVICE or FAULT. See Fig. 1. The
arrowheads darken to indicate the existing EAC
condition. See Table 1.
INSTALLATION
When Installing this Product..
1.
Read these instructions carefully. Failure to follow
the instructions could damage the product or cause
a hazardous condition.
2.
Check the ratings given in the instructions and on
the product to make sure the product is suitable for
your application
3.
Installer must be a trained, experienced service
technician.
4.
After completing the installation, use these instruc-
tions to check out the product operation.
Location
The styling of the W8600F is designed to blend with the
latest T8600 family of Honeywell Chronotherm¨ IV
Deluxe Programmable Thermostats. A special mounting
template is included for mounting next to the T8600. The
W8600F can also be mounted at any other convenient
location in the living area or equipment room. See Fig. 2.
NOTE:
The W8600F shares no common electrical con-
nections with the thermostat.
Fig. 1. W8600F Air Cleaner Monitor features.
a
The reset button is located on the bottom of W8600F.
After the prefilters and cells are cleaned and reinstalled,
press this button to turn off the SERVICE indicator and
reset the wash frequency timer.
Table 1. Description of W8600F Function Indicator
Panel.
Indicators
Condition
ON
EAC is powered and system blower is
running.
BATTERY
Battery that maintains W8600F
memory is low and needs to be
replaced.
SERVICE
EAC prefilter and cells need to be
washed
a
.
FAULT
•Shorting of collector plates.
•Continuous ionizer or collector plate
arcing.
•Power supply failure.
•Excessive current.
•Major reduction in high voltage.
•EAC prefilter and cells are past
SERVICE level of dirt and need to be
washed immediately.
Call a service technician.
ON
BATTERY
SERVICE
FAULT
Air Cleaner Monitor
FUNCTION
INDICATOR
PANEL
LCD
RESET BUTTON
M11965
69-1200-2.fm Page 1 Tuesday, December 3, 2002 11:21 AM
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Other Manuals for Honeywell W8600F
Summary
W8600F AIR CLEANER MONITOR 69-1200—2 2 Fig. 2. W8600F mounting locations. Mounting The following mounting instructions assume that theW8600F is mounted next to a T8600 Thermostat. Ifinstalling the monitor at another location, modify theprocedure to fit the installation. 1. Hold the mounting template...
W8600F AIR CLEANER MONITOR 3 69-1200—2 Select Wash Frequency Use the W8600F DIP switches to program the timebetween SERVICE indications. Be sure to select thesetting according to the conditions of the home. Factorsto consider include the duty cycle of the EAC, thenumber of people and pets, and activ...
69-1200—2 G.H. Rev. 12-02 www.honeywell.com W8600F AIR CLEANER MONITOR Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers. Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive G...