- Page 3 – INTRODUCTION; Description of Devices; LonW orks
- Page 4 – Control Application; Control Provided; T7770 A through D W all Modules.; Organization of Manual; Title
- Page 5 – Product Names; T7770A1xxx W all Module with temperature sensor only -
- Page 6 – Agency Listings; Device; Abbreviations and Definitions; CO2 - Carbon Dioxide. Often used as a measure of indoor air quality.
- Page 8 – to the temperature change of the sensing element.; Construction; Controllers
- Page 11 – Performance Specifications
- Page 14 – CAUTION; Wall Modules
- Page 15 – Configurations
- Page 16 – of CO
- Page 17 – APPLICATION STEPS; Overview; Description; Step 1. Plan The System
- Page 18 – Step 2. Determine Other Bus Devices Required; One E-Bus Segment Example; Step 3. Lay Out Communications and Power Wiring
- Page 20 – IMPORTANT; Power Wiring
- Page 22 – Fig. 12. Power wiring details for one Excel 10 per transformer.
- Page 23 – Notes on power wiring:
- Page 24 – Step 4. Prepare Wiring Diagrams; General Considerations; approved shielded cable.
- Page 29 – PWM
- Page 30 – E-Bus Termination Module
- Page 32 – FDEOHV (%XV VHJPHQW ZLUHV DQG 7HUPLQDWLRQ 0RGXOH
- Page 33 – Step 5. Order Equipment; Table 8. Excel 10 W7761A Device Ordering Information.
- Page 36 – Step 6. Configure Devices; Troubleshooting Excel 10 Controllers and Wall Modules
- Page 37 – The alarm reporting has been turned off by the DestManMode. No more; Broadcasting the Service Message
- Page 38 – T7780 DDWM Bypass Pushbutton; Pressing the bypass pushbutton whenever a Carat (
- Page 39 – APPENDICES; SENSOR CALIBRATION; The resistive temperature sensors and; CUSTOM MAPPING
- Page 40 – ADDING OTHER VOLTAGE/CURRENT SENSORS
- Page 42 – Common Operations
- Page 71 – Approximate Memory Size Estimating Procedure.
- Page 72 – Resistance Ohms
- Page 73 – Table E-3 Sensor Resistance Versus Temperature.
- Page 75 – Humidity Percentage
- Page 78 – Table E-9 lists the points for Sensor Voltage versus CO; CO
- Page 79 – Sensor Voltage
- Page 80 – KRQH
U.S. Registered Trademark
Copyright
1998 Honeywell Inc.
•
All Rights Reserved
LonWorks
LonMark
and LonMark
logo are Registered
Trademarks of Echelon
Corporation.
74-2699
CONTENTS
Table of Contents
Introduction
...........................................................................................................................
Description of Devices .......................................................................................
4
Control Application .............................................................................................
5
Control Provided.................................................................................................
5
Products Covered...............................................................................................
6
Organization of Manual ......................................................................................
6
Applicable Literature ..........................................................................................
6
Product Names ..................................................................................................
6
Agency Listings ..................................................................................................
7
Abbreviations and Definitions .............................................................................
7
Construction .......................................................................................................
9
Controllers .....................................................................................................
9
Performance Specifications ...................................................................... 12
W all Modules ................................................................................................. 15
Configurations .................................................................................................... 16
Mixed-Output-Type Control ........................................................................... 17
Occupancy Sensor ........................................................................................ 17
W indow Open/Closed Digital Input................................................................ 17
W all Module Options ..................................................................................... 17
Dirty Filter Monitor ......................................................................................... 17
Indoor Air Quality (IAQ) Override................................................................... 17
Application Steps
...........................................................................................................................
Overview ............................................................................................................ 18
Step 1. Plan The System.................................................................................... 18
Step 2. Determine Other Bus Devices Required ................................................ 19
Step 3. Lay Out Communications and Power W iring ......................................... 19
E-Bus Layout ................................................................................................. 19
Power W iring ................................................................................................. 21
Power Budget Calculation Example:......................................................... 21
Line Loss: ................................................................................................. 22
Step 4. Prepare W iring Diagrams ...................................................................... 24
General Considerations ................................................................................. 24
W 7761A Devices ........................................................................................... 24
E-Bus Termination Module ............................................................................ 30
Step 5. Order Equipment.................................................................................... 33
Step 6. Configure Devices.................................................................................. 36
Step 7. Troubleshooting ..................................................................................... 36
Troubleshooting Excel 10 Controllers and W all Modules .............................. 36
Temperature Sensor and Setpoint Potentiometer Resistance Ranges ......... 36
Alarms ........................................................................................................... 36
Broadcasting the Service Message ............................................................... 37
W 7761A Controller Status LEDs ................................................................... 37
T7780 DDW M Bypass Pushbutton ................................................................ 38
List of Figures
...........................................................................................................................
2
Fig. 1. Typical system overview. ........................................................................
4
Fig. 2. Typical W 7761A control application. .......................................................
5
Fig. 3. Excel 10 W 7761A Remote I/O Device. ................................................... 10
Fig. 4. W 7761A construction. ............................................................................. 11
Excel 10 W7761A Remote Input/Output
Device
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Other Manuals for Honeywell W7761A
Summary
EXCEL 10 W7761A INPUT/OUTPUT DEVICE 3 74-2699 INTRODUCTION Description of Devices The W 7761A, Excel 10 Remote Input/Output device, provides auxiliary inputs and outputs for use with an Excel 10 ZoneManager and Excel 10 controllers over the Echelon ® LonW orks ® E-Bus. These I/O points are configure...
EXCEL 10 W7761A INPUT/OUTPUT DEVICE 4 74-2699 Control Application The W 7761A, Excel 10 Remote Input/Output device, provides auxiliary inputs and outputs for use with an Excel 10 ZoneManager and Excel 10 controllers over the Echelon ® LonW orks ® E-Bus. The W 7761A Remote Input/Output Device can be ...
EXCEL 10 W7761A INPUT/OUTPUT DEVICE 5 74-2699 74-2698 Excel 10 W 7761A Device Specification Data 74-2956 Excel 10 W 7750A,B Controller Specification Data 74-2697 T7770A through G W all Module Specification Data 74-2955 T7780 Digital Display W all Module Specification Data 74-2950 Excel 10 Q7750A, Zo...