  • Page 2 – SPECIFICATIONS
  • Page 4 – INSTALLATION; Mounting; Identifying DIP Switches; Wiring; CAUTION
  • Page 5 – Conventional Thermostats
  • Page 6 – Heat Pump Thermostats
  • Page 7 – Fig. 5. Heat pump thermostat with separate Y1 and W1; ARD or ZD Dampers; Fig. 6. Heat pump thermostat with single Y thermostat
  • Page 8 – cool single Y thermostat wiring.
  • Page 9 – Fig. 12. MARD or ML6161 Damper Motor Actuator using; Transformer; Discharge Air and Outdoor Temperature Sensors; Fig. 14. Wiring C7735A Discharge Air Temperature Sensor
  • Page 10 – Conventional Equipment
  • Page 11 – Heat Pump Equipment
  • Page 12 – auxiliary and emergency heat.
  • Page 13 – Water Source Heat Pumps; STARTUP AND CHECKOUT
  • Page 14 – Purge Mode; Single and Multi-Stage Operation; Single Stage; THERMOSTAT-CONTROLLED STAGES
  • Page 15 – HEAT PUMP OPERATION
  • Page 16 – Thermostat Operation; HEAT PUMP THERMOSTATS WITH SINGLE Y OUTPUT; Emergency Heat Control; Rebooting Microprocessor
  • Page 17 – Circuit Breaker Protection; Dip Switch
  • Page 18 – TROUBLESHOOTING; Symptom
  • Page 19 – LED
Loading the manual

PRODUCT DATA

68-0259-1

® U.S. Registered Trademark
Copyright © 2002 Honeywell • All Rights Reserved

TZ-4 TotalZone® Zone Control Panel

APPLICATION

The TZ-4 TotalZone Zone Control Panel controls single-stage,

multi-stage, conventional or heat pump heat/cool equipment.

It controls 2, 3 or 4 zones, and is expandable up to 32 zones

with optional TotalZone® Add-A-Zone™ Four Zone Control

Panel.

FEATURES

• Up to three stages heat and two stages cooling can be

controlled by thermostat, built-in timer, or based on

the percentage of zones calling.

• Controls single-stage, multi-stage, conventional, heat

pump or dual-fuel equipment.

• Controls up to four zones and can be expanded up to

32 zones with Add-A-Zone Control Panels.

• Uses Honeywell four-wire, single-stage, multi-stage, or

select heat pump thermostats.

• Zone-A-Lone central setback feature.
• Purge timer protects equipment between calls for heat

or cool with choice of panel or HVAC equipment

controlled fan.

• System and zone damper LEDs indicate system and

damper status.

• Individual zone fan control.
• Discharge Air Temperature Sensor for capacity control

with adjustable high and low limits.

• Thermal circuit breaker protects panel and transformer

from damage if miswired.

For Internet access:

www.honeywellzoning.com

For technical support, call 1-800-828-8367.

To download Zoning literature: http://hbctechlit.honeywell.com

Contents

Application .........................................................................

1

Features ............................................................................

1

Specifications ....................................................................

2

Installation .........................................................................

4

Startup and Checkout ........................................................ 12

Operation........................................................................... 12

Troubleshooting ................................................................. 17

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SPECIFICATIONS

TZ-4 TOTALZONE® ZONE CONTROL PANEL 68-0259-1 2 SPECIFICATIONS Input Ratings: Voltage: 20-30 Vac, 50/60 Hz. Power: 13 VA, nominal. Output Ratings: 1.5A run, 200,000 cycles (30 Vac). 3.5 inrush. 1.5A run, 100,000 cycles (30 Vac) 7.5A inrush. Humidity Ratings: 5 to 90 percent RH, non-condensing. Temper...

Page 4 - INSTALLATION; Mounting; Identifying DIP Switches; Wiring; CAUTION

TZ-4 TOTALZONE® ZONE CONTROL PANEL 68-0259-1 4 INSTALLATION Mounting CAUTION Equipment Damage Hazard. Do not mount TZ-4 inside HVAC equipment Mount only on wall or on cold air return. Identifying DIP Switches This panel has two banks of DIP switches, DIP switch 4 (S4) and DIP switch 5 (S5), see Fig ...

Page 5 - Conventional Thermostats

TZ-4 TOTALZONE® ZONE CONTROL PANEL 5 68-0259-1 Wiring Diagrams (Fig. 3 and 4) Conventional Thermostats Conventional (RWYG) thermostats can be used to control conventional, multi-stage, and heat pump equipment. If the thermostat has a common terminal, it is wired to C on the panel, see Fig. 3. A mult...