Table of Contents:

  • Page 2 – Installation Guide; Wallplate installation; MERCURY NOTICE; instructions regarding recycling and proper disposal.; CAUTION: ELECTRICAL HAZARD; Wall anchors; Must be installed by a trained, experienced technician; can damage the product or cause a hazardous condition.
  • Page 4 – Wiring; Terminal Designations; Conventional Terminal Letters:; Heat Pump Terminal Letters:; Optional THP9045 Wiring Module; Heat Only System; Series 20 valve terminal “W”; Optional THP9045 Wiring Module; Wiring guide—conventional systems
  • Page 5 – Wiring guide—heat pump systems
  • Page 6 – PM; st; Installer setup; DONE
  • Page 7 – Setup functions; bold
  • Page 8 – Gas or oil furnaces of less than 90% efficiency; Furnace filter
  • Page 10 – TEST; Cooling system; Installer system test; The TH8320ZW is powered by Z-Wave
  • Page 11 – thermostat from the
  • Page 12 – that are not in the direct reach of Z-wave protocol.; Association
  • Page 14 – Special functions; Auto Changeover; (Setup Function 0530): Allows the thermostat to “learn” how long the; Compressor Protection; Please contact your distributor to order replacement parts.; Accessories & replacement parts
  • Page 15 – Regulatory information; ) This device may not cause harmful interference, and
  • Page 16 – Automation and Control Solutions
Loading the manual

TH8320ZW

Touch-screen Thermostat

Installation

Guide

® U.S. Registered Trademark.

US Patent No. 6,574,581, 6,975,958, 7,114,554,

7,346,467, 7,636,604, 7,693,582, 7,788,936,

7,845,576, and other patents pending.

Copyright © 2013 Honeywell International Inc.

All rights reserved.

69-2486-09

System Types

• Gas, oil, or electric heat with air

conditioning

• Warm air, hot water, high

efficiency furnaces, heat

pumps, steam, gravity

• Heat only — including power to open

and close zone valves (Series 20), and

normally open zone valves

• Heat only with fan

• Cool only

• 750 mV heating systems

This manual covers the TH8320ZW.

This thermostat contains a Lithium battery which may contain Perchlorate material.

Perchlorate Material—special handling may apply.

See www.dtsc.ca.gov/hazardouswaste/perchlorate

Need Help?

For assistance with this product please visit

http://customer.honeywell.com

or call Honeywell Customer Care toll-free at

1-800-468-1502

This is a legacy product document
supported by Resideo. It is no
longer manufactured

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Honeywell TH8320ZW

Summary

Page 2 - Installation Guide; Wallplate installation; MERCURY NOTICE; instructions regarding recycling and proper disposal.; CAUTION: ELECTRICAL HAZARD; Wall anchors; Must be installed by a trained, experienced technician; can damage the product or cause a hazardous condition.

Installation Guide 2 69-2486—09 M29481 Wallplate installation 1. Separate wallplate from thermostat. 2. Mount wallplate as shown below. MERCURY NOTICE If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact your local waste ma...

Page 4 - Wiring; Terminal Designations; Conventional Terminal Letters:; Heat Pump Terminal Letters:; Optional THP9045 Wiring Module; Heat Only System; Series 20 valve terminal “W”; Optional THP9045 Wiring Module; Wiring guide—conventional systems

Installation Guide 4 69-2486—09 Wiring See [notes] below [1] Power supply. Provide disconnect means and overload protection as required. [3] Connection to 24VAC common at the transformer is required. [9] See "Optional THP9045 Wiring Module" on page 14 for more details. Terminal Designations ...

Page 5 - Wiring guide—heat pump systems

TH8320ZW 5 69-2486—09 1H/1C Heat Pump (no auxiliary heat) Rc Power [1] R [R+Rc joined by jumper] O/B Changeover valve [5] Y Compressor relay G Fan relay C 24VAC common [3] K Optional THP9045 Wiring Module Terminal [9] 2H/1C Heat Pump (with auxiliary heat) L Equipment monitor [6, 7] E Emergency heat ...