Page 3 - Introduction; In this package you will find:
3 Introduction Thank you for selecting the Honeywell Professional Weather Station with Remote control. This compact and easy-to-use product features a wide variety of time and weather data, such as precise atomic time, perpetual calendar, air temperature, relative humidity, barometric pressure, wind...
Page 4 - Standard Package Contents
4 Standard Package Contents Picture Components Main Unit Remote Control AC/DC 7.5V power adaptor UV Sensor consists of: Sensor Unit U-Shaped Sensor holder Circular Ground Stand Stake Base Wall-Mounting Base Thermo Hygrometer Sensor Rain Gauge consists of: Funnel shaped top with battery compartment R...
Page 5 - Installation
5 4 screws for securing rain gauge to the flat surface; 4 screws for securing anemometer to vertical surface Mounting hardware 2m (6ft) USB cable PC connection cable Installation The Honeywell Professional Weather Station TE923W operates at 433MHz radio frequency, so no wire installation is required...
Page 6 - Before you begin; ALWAYS; before; IMPORTANT; FEATURES
6 Before you begin • We recommend using alkaline batteries for the remote weather sensors and the main unit when temperatures are above 32°F (0°C). We recommend using lithium batteries for the remote weather sensors when temperatures are below 32°F (0°C). • Avoid using rechargeable batteries. (Recha...
Page 8 - Mounting
8 screwdriver • Insert two 2 “AA” size 1.5V batteries (not included) matching the polarities shown in the battery compartment. • Replace the battery compartment door and secure the screw • Screw the UV sensor unit lid back Mounting There are three different options available for mounting the UV sens...
Page 9 - B. BATTERY COMPARTMENT; Holds two AA-size batteries
9 Placement tips: The UV sensor should be mounted in the area free of sunlight shadows or reflections from the nearby objects. Remote Thermo-Hygrometer Sensor FEATURES • Remote data transmission to the main unit via 433 MHz signal • 328 feet (100 meters) operating range without interference • LCD di...
Page 10 - Replace the battery compartment door and secure the screws.
10 • Replace the battery compartment door and secure the screws. • Secure the thermo-hygrometer remote sensor in the desired location. Mounting • The remote thermo-hygrometer sensor can be placed on the flat surface or mounted on the wall in vertical position • Use the wall mount hardware and screws...
Page 11 - Rain Gauge
11 Rain Gauge FEATURES • Precipitation measurement • Remote transmission of the rainfall data to the main unit via 433 MHz signal • 100 feet (30 meters) operating range without interference • Built-in installation level • Non-corrosive protective screen A. Rain gauge bucket Contains mechanical compo...
Page 15 - Main Unit; Weather
15 nearby trees, buildings or other structures. • For optimal performance, mount the anemometer at 33 feet (10meters) above the ground in unobstructed area. Mounting Mount the anemometer onto a vertical surface, using the fittings provided. Placement • The anemometer should be mounted in an open are...
Page 18 - OPEN; button on the upper right corner of the; Main unit and handheld remote control adequate buttons; -Allows displaying the sea-level pressure history
18 Buttons and Controls Most of the handheld remote control buttons are corresponding to the main unit controls. To expose the main unit control buttons, press the OPEN button on the upper right corner of the main unit and the controls’ cover door will open. Main unit and handheld remote control ade...
Page 21 - using the switch, located on the back panel.; NOTE; periodically for useful tips and the
21 using the switch, located on the back panel. NOTE : For an automatic control function the main unit must be plugged into the wall power outlet via the AC/DC adaptor provided. Connecting Weather Station to a Personal Computer To collect and manipulate data from your weather station you may connect...
Page 22 - Navigating through the modes; UP
22 Navigating through the modes The main unit has seven (7) different modes (Windows ) each displaying the separate data category. When a specific mode (Window) is selected the corresponding icon will start flashing. Press UP button on the main unit or the handheld remote control to cycle through th...
Page 25 - Operations and Window Selection
25 Customizing your Weather Station To use your station, you will have to complete the steps identified under INITIAL SETUP while this section of the manual will provide you with additional operational details and suggestions for custom settings and alarms including: • The time alarms (Clock and Ala...
Page 40 - Maintenance
40 Memory Reset Procedure These steps will completely reset all of the parameters stored in memory. • On the main unit press and hold SNOOZE and UP buttons for 4 seconds until the backlight will flash • Press SET button clearing the memory -the main unit will start beeping with 1 second delay. • Wai...
Page 41 - PRECAUTIONS
41 precipitation measurements. • Detach the protective screen and lid. • Clean with soapy water and a damp cloth, removing dirt, leaves or debris • Clean small holes and parts with Q-tips or pipe-cleaner. • Watch out for spiders or insects that might have crawled into the funnel. • Clean the swingin...
Page 43 - Appendix - City Codes; US and Canadian Cities
43 Appendix - City Codes US and Canadian Cities City Code Zone DST City Code Zone DST Atlanta, Ga. ATL -5 SU Memphis, Tenn. MEM -6 SU Austin, TX AUS -6 SU Miami, Fla. MIA -5 SU Baltimore, Md. BWI -5 SU Milwaukee, Wis. MKE -6 SU Birmingham, Ala. BHM -6 SU Minneapolis, Minn. MSP -6 SU Boston, Mass. BO...
Page 45 - Specifications
45 DST (Daylight Savings Time) definitions : SA = Australian DST. SB = South Brazilian DST. Changes annually. SC = Chile DST SE = Standard European DST. SG = Egypt DST SH = Havana, Cuba DST SI = Iraq and Syria DST SK = Irkutsk & Moscow DST SM = Montevideo, Uruguay DST SN = Namibia DST SP = Parag...
Page 47 - FCC STATEMENT
47 Memory size: Ram 128 MB or more Hard disk size: 100 MB free space or more Optical Device: 2 x CD-Rom drive Power Main unit: 4 x UM-3 or AA 1.5V battery; 7.5V AC/DC power adaptor (200mA; center pin positive) Remote Thermo Hygrometer: 2 x UM-3 or AA 1.5V battery Remote UV sensor: 2 x UM-3 or AA 1.5...
Page 48 - DECLARATION OF CONFORMITY
48 protection against harmful interference in a residential installation. This equipment, installed and used in accordance with the instructions, may cause harmful interference to radio communications. There is no guarantee that interference will not occur in a particular installation. If this equip...