Honeywell T841A1498 - Manual

Honeywell T841A1498

Honeywell T841A1498 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
Page: / 6

Table of Contents:

  • Page 2 – OPERATION; RECYCLING NOTICE; INSTALLATION; When Installing this Product...; Location; CAUTION
  • Page 3 – SETTINGS; Heat Anticipator Setting; FAN Switch Setting
  • Page 6 – CHECKOUT; Heating; Cooling; Fan
Loading the manual

MOUNTING
HOLES (4)

WIRING TERMINAL
(UP TO 12)

M2960A

BACK OF DEVICE

80

70

60

50

EM. HEAT HEAT OFF COOL

80
70
60
50

AUTO ON

FAN

EM. HEAT AUX. HEAT

CHECK

FRONT OF DEVICE

FAN SWITCH

SYSTEM SWITCH

COVER

THERMOMETER

SET POINT
SCALE

LED (UP
TO THREE)

T841A Heating-Cooling

Heat Pump Thermostat

X-XX UL

INSTALLATION INSTRUCTIONS

®U.S. Registered Trademark
Copyright © 1997 Honeywell Inc. • • All Rights Reserved

APPLICATION

The T841A Heating-Cooling TRADELINE® Thermostat
provides 24 Vac control of two-stage heating and one-
stage cooling in heat pump systems, using manual
changeover. This thermostat provides SYSTEM switch
selections of EM. HEAT-HEAT-OFF-COOL and FAN
switch selections of AUTO-ON. See Fig. 1. See Table 1 for
T841A TRADELINE® specifications.

Test holes are provided on the front of the thermostat to
accommodate test meter probes without removing the
thermostat from the wall. Remove the cover of the
thermostat to expose the test holes, which are labeled to
correspond with the terminals on the back of the
thermostat.

Table 1. T841A TRADELINE® Specifications.

Fig. 1. External view of T841A.

a

EM. HEAT LED also indicates compressor malfunction.

b

Premier White® color.

c

Sold only in Australia: degrees C.

d

CHECK LED indicates compressor malfunction.

OS Number

LED

Indication

Changeover

Heat

Anticipation

Terminal

Designations

Remarks

System

Switch

Auto Fan

in EM.

HEAT

T841A1308

EM. HEAT

a

,

AUX. HEAT

Manual Cool
or Heat

Stage 2 fixed,
0 to 1.5A

G, R, W

2

, E,

L, B, X, Y, O

Use when E
and W

2

are

jumpered.

EM. HEAT,
HEAT, OFF,
COOL

No

T841A1316

G, R, E, L, X
W

2

, B, W1,

Y

1

, O

Does not
replace
T841A1068.

Yes

T841A1423

b

EM. HEAT,
AUX. HEAT,
CHECK

d

Stage 2
adjustable, 0.1
to 1.2A

W

3

, G, R, W

2

,

E, L, B, X, Y,
O

Not for systems
with E to W

2

jumper

T841A1464

b,c

T841A1498

EM. HEAT

Stage 2 fixed,
0 to 1.5A

G, R, W, H, B,
X, O, Y

Exact
replacement for
York model no.
2TH11703324

T841A1506

b

69-0452-8

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - OPERATION; RECYCLING NOTICE; INSTALLATION; When Installing this Product...; Location; CAUTION

69-0452—8 2 T841A HEATING-COOLING HEAT PUMP THERMOSTAT OPERATION The stages of heat make sequentially as the temperature drops. Make refers to the mercury switch initiating a call for heat or cool. There is about 1 ° F (0.6 ° C) between stages so the second stage (auxiliary heat) makes only when the...

Page 3 - SETTINGS; Heat Anticipator Setting; FAN Switch Setting

69-0452—8 3 T841A HEATING-COOLING HEAT PUMP THERMOSTAT ODT 1 EHR 1 RTD 2 RTD 1 ODT 2 RTD 3 ERH 2 RD G SYSTEMSWITCH EM. HEAT HEAT OFF COOL H2 FALL H1 C1 FALL H1 & C1ANTICIPATOR H2 ANTICIPATOR FAN SWITCH AUTO ON COMPRESSORCONTACTOR EM. HEATRELAY CHANGEOVERRELAY (HEAT) AUX. HT. LED (GREEN) X W2 B R...

Page 6 - CHECKOUT; Heating; Cooling; Fan

69-0452—8 6 T841A HEATING-COOLING HEAT PUMP THERMOSTAT CHECKOUT Heating Move the SYSTEM switch on the thermostat to HEAT andthe FAN switch to AUTO. Move the setpoint lever to about10 ° F (6 ° C) above the room temperature. Heating should start and the fan should run. Move the setpoint lever about10 ...