Honeywell RTH111- Manual

Honeywell RTH111

Honeywell RTH111– Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 2 – Technical Data; Printed in USA
  • Page 3 – Fonctionnement; Remplacement des piles; Guide de l’utilisateur
  • Page 4 – Fiche technique
  • Page 5 – Cool On; Off; Funcionamiento; Guía del usuario
  • Page 6 – Especificaciones técnicas
  • Page 7 – Réglage du ventilateur; Si le réglage est incorrect :; Installation des piles; Menu de configuration
Loading the manual

RTH111

69-2061EFS

-01

11/09

1/

8

1.1

Controls

1.2

Display screen

1.3

System switch

Use the

System

switch to place the system in one of the following

modes.

Cool

: System is in Cooling mode.

Off

: System is off.

Heat

: System is in Heating mode.

CAUTION: EQUIPMENT DAMAGE HAZARD

Do not use Cooling mode when the outdoor temperature
is below 50 °F (10 °C).

1.4

Fan switch

Use the

Fan

switch to select the fan operation.

Auto

: The fan runs only when heating or cooling is actually taking

place (commonly used setting).

On

: The fan runs continuously. Use this setting for improved air

circulation or for more efficient air cleaning.

1.5

Temperature adjustment

Press the

S

or

T

button once to display the setpoint temperature.

Press either button more than once to change the setpoint.
The ambient (measured) temperature is normally displayed. To view
the setpoint temperature, press either of the temperature adjustment
buttons once. The setpoint temperature will appear for five seconds.

1.6

Built-in compressor protection

Your thermostat has a feature that helps prevent damage to the
compressor of your air conditioning system. Because damage can
occur if the compressor is restarted too soon after shutdown, this
feature forces the compressor to wait five minutes before restarting.
During the wait time, the message

Cool On

flashes on the screen.

When the safe wait time has elapsed, the message stops flashing
and the compressor turns on.

Set the

System

switch to

Off

before removing the

batteries. Otherwise, the heating/cooling system could
remain activated even when batteries are removed.

Install two fresh AAA batteries when the low-battery icon flashes on
the screen. The icon appears for 60 days before the batteries are
depleted. Replace batteries once a year, or when you will be away for
more than a month.
The settings are stored in non-volatile (permanent) memory and are
thus saved when the thermostat is without batteries.

n

Operation

1.

System switch

Fan switch

Temperature

adjustment buttons

1

When

Cool On

is flashing, this means the compressor protection is engaged (see

section 1.6).

Temperature

System status

Cool On

: Cooling is

activated.

1

Heat On

: Heating is

activated.

Low-battery warning

Setpoint indicator

Appears when the

setpoint temperature

is displayed.

o

Battery replacement

2.

p

In case of difficulty

3.

Screen is blank.

• Ensure two fresh AAA alkaline batteries are

correctly installed.

Temperature settings
cannot be changed.

• The

System

switch is off.

• You are setting the temperatures outside

their allowable ranges:

• Heat: 40 °F to 90 °F (4.5 °C to 32 °C).
• Cool: 50 °F to 99 °F (10 °C to 37 °C).

Cool On

is flashing. • The compressor protection delay has been

activated. Cooling will not be activated until
the delay ends (maximum of five minutes).

HI

appears on the

screen.

• The ambient (measured) temperature is

above 122 °F (50 °C).

LO

appears on the

screen.

• The ambient (measured) temperature is

below 32 °F (0 °C).

E1

appears on the

screen.

• The temperature sensor circuit is opened.

Replace the thermostat.

E2

appears on the

screen.

• The temperature sensor circuit is shorted.

Replace the thermostat.

RTH111

User Guide

Non-programmable Thermostat

400-631-001-A (RTH111 User 69-2061EFS).book Page 1 Tuesday, June 5, 2007 2:24 PM

69-2061EFS-01

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Honeywell RTH111

Summary

Page 2 - Technical Data; Printed in USA

RTH 111 69-2061EFS -01 11/09 2/ 8 Power Supply • 2 AAA batteries Maximum Load • 1 A @ 24 VAC per output Temperature Ranges • Heat: 40 °F to 90 °F (4.5 °C to 32 °C)• Cool: 50 °F to 99 °F (10 °C to 37 °C) Operating Ambient Temperature • 32 °F to 122 °F (0 °C to 50 °C) Shipping Temperature • -40 °F to ...

Page 3 - Fonctionnement; Remplacement des piles; Guide de l’utilisateur

RTH111 69-2061EFS -01 11/09 3/ 8 1.1 Contrôles 1.2 Affichage 1.3 Bouton-sélecteur du système Utiliser le bouton-sélecteur System pour placer le système dans l’un des modes suivants :• Cool : Le système est en mode Climatisation. • Off : Le système est arrêté. • Heat : Le système est en mode Chauffag...

Page 4 - Fiche technique

RTH1 11 69-2061EFS -01 11/09 4/ 8 Alimentation • 2 piles AAA Charge maximale • 1 A @ 24 V c.a. par sortie Gammes de température • Chauffage : 4,5 °C à 32 °C (40 °F à 90 °F)• Climatisation : 10 °C à 37 °C (50 °F à 99 °F) Température de fonctionnement • 0 °C à 50 °C (32 °F à 122 °F) Température d’expé...

Other Honeywell Models