Honeywell rth230b- Manual
Honeywell rth230b– Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Pull out the battery cover.; Completing the Installation; Apply power back to the system.; System Operating Mode; J2 jumper
- Page 3 – Temporary Bypass; Warning; Configuration Menu
- Page 4 – Modifying the Schedule; Technical Specifications; Printed in USA
RTH230B
69-1800
-01
11/09
1/4
The RTH230B programmable thermostat can be used to control:
• a gas, fuel oil or electric furnace - 2 or 3 wires
• a central air conditioner - 2 or 3 wires
• a hot water system with or without pump - 2 wires
• a millivolt system - 2 wires
• a central heating and cooling system - 4 or 5 wires
Note
: These thermostats are not compatible with heat pumps or
multi-stage systems.
Features
• System operating mode selection: heat, cool or off
• Fan operating mode selection: automatic or on (continuous)
• Programmable heating and cooling cycle lengths: 10, 12, 15, 20
or 30 minutes
• Temperature display in °F or °C
• Battery replacement indicator
• 5-2 programming including:
- Preprogrammed energy-saving schedule
- Early Start
- Temporary bypass
- Time display (12 h or 24 h)
• Filter replacement indicator
2.1 Removing the Old Thermostat
IN ORDER TO AVOID ANY RISK OF ELECTRIC SHOCK, CUT
POWER TO THE HEATING SYSTEM.
n
Remove the old thermostat to access the wires.
Warning
: If the old thermostat was mounted onto an electrical box,
it was probably powered by 120/240 volts. In this case, this thermo-
stat cannot be used.
o
Identify and label each wire (with the corresponding letter on
the wire terminal) and remove them from the terminals.
p
If necessary, strip the end of each wire (maximum of 1/4 inch).
q
Wrap the wires around a pencil to prevent
them from falling into the wall.
r
If the hole in the wall is too big, insulate it
using a non-flammable material in order to
avoid air draughts behind the thermostat.
2.2 Installing the New Baseplate
For a new installation, choose a location approximately 5 feet
(1.5 m) above the floor and on an inside wall. Avoid draughty
areas (top of staircase, air outlet, etc.), dead air spots (behind
doors), direct sunlight or areas near concealed pipes or chim-
neys.
n
Remove the thermostat faceplate.
o
Loosen the locking screw to separate the thermostat from its
baseplate (the screw cannot be completely removed).
p
Tilt the thermostat upwards.
q
Mark and bore the appropriate mounting holes (or use the
existing holes). Insert the plastic anchors.
r
Pass the wires through the opening of the baseplate and fix the
baseplate to the wall using the screws provided.
2.3 Connecting the Thermostat
The connection of the new thermostat should be similar to that of
the old thermostat; however, it can vary depending on the installa-
tion.
Note
: The red jumper wire between the Rc and Rh terminals must
be removed in 2- or 5-wire installations. The jumper must be used in
3- or 4-wire installations if you wish to use the mode selector switch
for the fan.
1. Introduction
2. Installation
RTH230B
Programmable Electronic Ther mostat
Installation and User Guide
Display
Adjustment
buttons
System operating
mode selector
Fan operating
mode selector
Programming
buttons
Rh
Heating power supply
Rc
Cooling power supply
W
Heating signal
Y
Cooling signal
G
Fan
69-1800-01
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Other Manuals for Honeywell rth230b
Summary
RTH230B 69-1800 -01 11/09 2/4 2.3.1 2-wire Heating 2.3.2 2-wire Cooling 2.3.3 3-wire Heating 2.3.4 3-wire Cooling 2.3.5 4-wire Heating and Cooling 2.3.6 5-wire Heating and Cooling 2.4 Setting J2 Jumper The jumper defines the fan operation when the fan is placed in auto-matic mode. 2.5 Installing the...
RTH230B 69-1800 -01 11/09 3/4 3.2 Fan Operating Mode Use the selector switch to set the fan to automaticmode (AUTO) or continuous mode (ON). Note : This switch is not used if you have a 2-wire installation as the fan is not connected to the thermo-stat. 3.3 Displaying the Temperature The actual temp...
RTH230B 69-1800 -01 11/09 4/4 5.2 Energy-saving Schedule Your thermostat is preprogrammed with an energy-saving schedule.The schedule automatically controls your heating or cooling systemby switching from one setpoint to the next according to the presettimes. Note : To use the schedule, place the th...