Honeywell RCWL301A- Manual

Honeywell RCWL301A

Honeywell RCWL301A– Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 2 – Installation instructions–RCWL301A
  • Page 3 – Chime Position; Typical Connection; Diagram Application
  • Page 4 – Specification
  • Page 5 – RCWL301A Manual de instrucciones
  • Page 7 – Posición de la campanilla; un pulsador del timbre cableado estándar; Abra el pulsador/convertidor del timbre; Presione el botón; Conexión promedio; Diagrama Aplicación; Especificación
  • Page 8 – Automation and Control Solutions; Honeywell International Inc.; Se escuchan dos “tonos” después del sonido normal de la campanilla...; Verifique que el control de volumen no esté en la posición mínima.; Desecho y reciclaje
Loading the manual

69-2139EFS—1

1

RCWL301A Instruction Manual

Premium Portable Wirefree Chime with Push, Converter, and Door Contacts
Thank you for choosing this Honeywell product. Please use the following instructions
to ensure correct installation and use. Keep these notes in a safe place for future
reference.

Checking Pack Contents

Unpack your chime kit and identify the following parts:

Chime

Wall mounting bracket

Bell push

Bell push/converter/extender

Door contacts

2x CR2032 battery for bell push and converter

4x mounting screws for door contacts

4x mounting screws for push/converter

2x mounting screws for chime

2x wall anchors

2x adhesive pads

Bell wire (for use with converter and door contact)

Self-adhesive icons

You will need:

3x LR6 ‘AA’ Alkaline batteries

Phillips screwdriver

Small flat bladed screwdriver

1/4-in. (6 mm) masonry drill

Safety

Before proceeding with the installation, please note the following safety warnings:

Always follow the manufacturer’s advice when using power tools and wear suitable
protective equipment (e.g. safety goggles) when drilling holes, etc.

Before drilling holes in walls, check for hidden electricity cables and water pipes.
The use of a cable/pipe locator is advisable if in doubt.

Quick Start

The bell push supplied with this kit is pre-programmed to operate with the chime. You
need to do the following to get started:

Open the bell push

Fit the push battery

Fit the chime batteries

Check the volume setting

When you operate the bell push, the chime will sound and the 1st icon will flash.

If you use the converter, an additional push or you want to assign a different
icon to your push, you will need to follow the Programming Procedure.

Open the bell push/converter/extender

Connect the push/converter/extender to the door contacts

Fit the push/converter/extender battery

Follow programming procedure to program push/converter/extender to the chime

When the door contacts (a normally closed circuit) are separated/opened the
alert will sound and the icon assigned to the converter will flash.

Mount the door contacts to the door and door frame.

Mount the push/converter/extender near the door frame.

Open the Bell Push

Insert a flat bladed screwdriver into the slot A at the base of the push. Carefully lever
the cover and base apart (Fig. 1).

Fit the Push Battery

Insert the CR2032 coin cell. Ensure the face marked ‘+’ is uppermost (Fig. 2).

Fit the Chime Batteries

To remove the chime battery cover, press at point B and slide the cover back 1/4 in. (5
mm), then lift off. Insert 3 x LR6 ‘AA’ alkaline batteries (not supplied). Observe polarity
as marked inside the battery compartment (Fig 3).

M27199

A

Fig. 1

M27153

CR2032

+

CR2032

+

Fig. 2

M27200

B

Fig. 3

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Honeywell RCWL301A

Summary

Page 2 - Installation instructions–RCWL301A

Installation instructions–RCWL301A 69-2139EFS—1 2 Sliding Window Release the catch (B) and slide open the window (Fig. 4). Volume Control The volume control is behind the sliding window on the front of the chime. Initially, set the control to mid-point. After you have tested your system, adjust to t...

Page 3 - Chime Position; Typical Connection; Diagram Application

Installation instructions–RCWL301A 69-2139EFS—1 3 Chime Position The Chime can be free standing or wall mounted using the wall mounting bracket provided. If wall mounting is preferred, screw the bracket to the wall (see Fig 7). The Chime hooks onto the wall bracket as illustrated. RPWL3045A Wireless...

Page 4 - Specification

Installation instructions–RCWL301A 69-2139EFS—1 4 Fix the push/converter/extender Mount using either the double-sided adhesive pad or the screws provided. (See Fig. 10 ). Test your converter before mounting. Avoid mounting to metal structures. Troubleshooting A ‘beep’ sound is heard in learn mode… •...

Other Honeywell Models