Honeywell R7851C - Manual

Honeywell R7851C

Honeywell R7851C – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 2 – ORDERING INFORMATION; SPECIFICATIONS
  • Page 4 – INSTALLATION; WARNING; CAUTION; Installing Flame Detector; WARNING
  • Page 6 – CHECKOUT; Preliminary Inspection
Loading the manual

PRODUCT DATA

65- 0109- 8

® U.S. Registered Trademark
Copyright © 2002 Honeywell • All Rights Reserved

R7824, R7847, R7848, R7849,R7851,R7861,

R7886 Amplifiers for

7800 SERIES Relay Modules

APPLICATION

The R7824C Rectification Flame Amplifier is a solid state plug-in

amplifier that responds to a rectified signal from a C7024E,F Self-

Check Ultraviolet Flame Detector to indicate the presence of

flame when used with an RM7824 Relay Module.

The R7847A,B Rectification Flame Amplifiers are solid state plug-

in amplifiers that respond to a rectified signal from a rectification

type flame detector to indicate the presence of flame when used

with 7800 SERIES Relay Modules.

The R7847C Self-Check Rectification Flame Amplifier is a solid

state plug-in amplifier that responds to a rectified signal from a

C7012E,F Self-Check Ultraviolet Flame Detector to indicate the

presence of flame when used with 7800 SERIES Relay Modules.

This is not European Community (CE) approved for EC7810,

EC7820, EC/RM7830 or EC/RM7850 Relay Modules.

The R7848A,B Infrared Flame Amplifiers are solid state plug-in

amplifiers that respond to an infrared signal from a C7015

Infrared Flame Detector to indicate the presence of flame when

used with 7800 SERIES Relay Modules.

The R7849A,B Ultraviolet Flame Amplifiers are solid state plug-in

amplifiers that respond to an ultraviolet signal from a C7027,

C7035 or C7044 Ultraviolet Flame Detector to indicate the

presence of flame when used with 7800 SERIES Relay Modules.

The R7851B Optical Flame Amplifiers are solid state plug-in

amplifiers that respond to optical signals from C7927, C7935,

C7915, and C7962 Flame Detectors to indicate the presence of

flame when used with 7800 SERIES Relay Modules.

The R7851C Dynamic Self-Check Optical Flame Amplifier is a

solid state plug-in amplifier that responds to ultraviolet signals

from C7961E Dynamic Shutter-Check ultraviolet flame detectors

to indicate the presence of flame when used with 7800 SERIES

Relay Modules.

The R7861A Self-Check Ultraviolet Flame Amplifier is a solid

state plug-in amplifier that responds to an ultraviolet signal from a

C7061 Self-Check Ultraviolet Flame Detector to indicate the

presence of flame when used with 7800 SERIES Relay Modules.

The R7886A Dynamic Self-Check Ultraviolet Amplifier is a solid

state plug-in amplifier that responds to a pulsed direct current

signal from a C7076A,C Ultraviolet Flame Detector with

adjustable sensitivity to indicate the presence of flame when used

with 7800 SERIES Relay Modules.

FEATURES

• Flame failure response time of 0.8 or 1 second; or 2.0 or

3.0 seconds, depending on the amplifier and relay module

selected. See Table 1.

• Plug-in to 7800 SERIES Relay Module through printed

circuit board edge connector keyed for proper orientation.

• Flame signal test jacks measure amplifier flame signal

voltage.

• 0.0 to 5.0 Vdc Flame signal strength reading range.
• Color coded label identifies flame detection type:

Green—rectification. Red—infrared.

Purple—ultraviolet. Blue—pulsed rectification.

White—optical.

• R7847B, R7848B, R7849B Dynamic Ampli-Check®

circuitry tests all flame amplifier components 12 times per

minute. The 7800 SERIES Relay Module locks out on

safety shutdown with amplifier failure.

• R7824C and R7847C Dynamic Self-Check Rectification

Amplifier, R7851C Dynamic Self-Check Optical Flame

Amplifier, R7861 Self-Check Ultraviolet Flame Amplifier

and R7886A Dynamic Self-Check Ultraviolet Amplifier test

the detectors and all electronic components in the flame

detection system 12 times per minute. The 7800 SERIES

Relay Module locks out on safety shutdown with flame

detection system failure.

NOTE:

NOTE:R7824C, Series 2 or greater, and R7847C,

Series 4 or greater, pulse shutter when signal of

1.5 Vac is sensed.

Contents

Application ........................................................................

1

Features ...........................................................................

1

Specifications ...................................................................

2

Ordering Information .........................................................

2

Installation ........................................................................

4

Checkout ..........................................................................

6

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - ORDERING INFORMATION; SPECIFICATIONS

R7824, R7847, R7848, R7849,R7851,R7861, R7886 AMPLIFIERS FOR 7800 SERIES RELAY MODULES 65-0109—8 2 ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number....

Page 4 - INSTALLATION; WARNING; CAUTION; Installing Flame Detector; WARNING

R7824, R7847, R7848, R7849,R7851,R7861, R7886 AMPLIFIERS FOR 7800 SERIES RELAY MODULES 65-0109—8 4 CAUTION Equipment Damage Hazard. Incorrect combination of relay module, amplifier and flame detector can cause equipment damage. In infrared applications (C7015 Infrared Flame Detector and R7848 Amplif...

Page 6 - CHECKOUT; Preliminary Inspection

R7824, R7847, R7848, R7849,R7851,R7861, R7886 AMPLIFIERS FOR 7800 SERIES RELAY MODULES 65-0109—8 6 3. Disconnect power supply before making wiring connections to prevent electrical shock and equipment damage. 4. All wiring must comply with appropriate electrical codes, ordinances and regulations inc...

Other Honeywell Models