Honeywell R7426A- Manual
Honeywell R7426A– Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Do not connect the secondary side of the transformer to
- Page 3 – CONFIGURATION AND CONTROL PARAMETERS
- Page 5 – Parameter Settings and Adjustment.
- Page 6 – CONFIGURATION SETTINGS; Direct - Reverse Action; How; Control Point / Setpoint Adjustment CPATYP; remote setpoint unit type; Output Control Range Selection
- Page 7 – Supply of Temperature Signal T2
- Page 8 – def
- Page 9 – Setting Guidelines for Proportional Band of P and
- Page 10 – Setting Guidelines for Reset Time of P+I Control; start
- Page 11 – Calibration of Temperature Sensors; OPERATING OVERVIEW; Display and Operation Elements; DISPLAY
- Page 12 – Changing Operating Modes
- Page 13 – Time Out; by the
- Page 18 – Interpreting Error Messages
- Page 20 – Table 17. Weekly schedule and holiday types
HONEYWELL
Copyright © 2007 Honeywell GmbH
All Rights Reserved
EN1B-0203GE51 R0507C
R7426A,B,C
TEMPERATURE CONTROLLER
WITH AND WITHOUT REAL-TIME CLOCK
INSTALLATION & START-UP INSTRUCTIONS
Fig. 1. Temperature Controller
Contents
General................................................................................ 1
Before Installation Note ....................................................... 1
Mounting.............................................................................. 1
Wiring .................................................................................. 2
Power Supply and Grounding .............................................. 2
Configuration and Control Parameters ................................ 3
Configuration Settings ......................................................... 6
Parameter Settings and Adjustment .................................... 8
Operating Overview ............................................................ 11
Notes (with RTC, only)....................................................... 19
GENERAL
This document provides instructions and procedures for
installing and starting up the Micronik 200 R7426A,B,C
controllers. No special tools are required for mounting and
installation. The user interface and liquid-crystal display allow
accurate and easy parameter setting and output adjustment.
BEFORE INSTALLATION NOTE
•
Visually inspect equipment for shipping damage.
Report any damage to the appropriate Honeywell
representative.
•
Refer to job drawings for specific installation
information and mounting location.
•
Verify the controllers will be adequately separated
from the main power supply, relays, or other equip-
ment which can possibly generate electromagnetic
interference.
•
Verify that the ambient temperature and the humidity
at the controllers will not exceed 0...50
°
C (32...122
°
F)
and 5 to 95% rh.
•
Use shielded wiring in areas with high EMI.
•
All wiring should be separated from power lines by at
least 150 mm (6’’).
•
Do not install controllers near frequency converters
or other high-frequency sources.
MOUNTING
The controllers can be mounted in an electric cabinet or other
suitable enclosure. They are suitable for back panel, DIN rail,
wall, or front panel mounting. The corresponding mounting
sequence, as well as dimensions and panel cut-out, are
illustrated in the mounting instruction sheet EN1B-0202GE51
supplied with the controllers.
If the compensation sensor signal (T3) is received from
another controller (parallel connection of compensation
sensor inputs), the jumper W303 has to be cut before
mounting the controller (see Fig. 2). This disconnects the
sensor from the internal power supply.
MicroniK 200
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Other Manuals for Honeywell R7426A
Summary
R7426A,B,C TEMPERATURE CONTROLLER WITH AND WITHOUT REAL-TIME CLOCK EN1B-0203GE51 R0507C 2 WIRING Screwless type, spring loaded terminals are provided on the controllers for panel and field wiring. These terminals are suitable for solid conductors as well as tinned or with multicore cable end, strand...
R7426A,B,C TEMPERATURE CONTROLLER WITH AND WITHOUT REAL-TIME CLOCK 3 EN1B-0203GE51 R0507C CONFIGURATION AND CONTROL PARAMETERS The controllers R7426A,B,C include two groups of settings *) (I and II) for control and configuration parameters that are automatically selected during programming. For para...
R7426A,B,C TEMPERATURE CONTROLLER WITH AND WITHOUT REAL-TIME CLOCK 5 EN1B-0203GE51 R0507C control par. setting I / setting II R7426 no. name description low high def. reso- lution unit A B C actual value P.01 W1 Main setpoint for input T1 0 50 / 130 21 / 70 0.5 ° C x x x P.02 Wlim Limit setpoint (lo...