Page 2 - integrated
Copyright© 2007 Honeywell. All rights reserved. All product and brand names are the service marks, trademarks, registered trademarks, or registered service marks of their respective owners. Printed in the United States of America. Honeywell reserves the right to change any information in this docume...
Page 4 - ONTENTS
PW-6000 Installation and Configuration Guide , Document 800-00005, Revision A iii C ONTENTS Notices................................................................................................................... 1 Warnings and Cautions ................................................................
Page 5 - IST; Figure 9: PW-6000 Host Port Configuration Screen with IP Client
PW-6000 Installation and Configuration Guide , Document 800-00005, Revision A v L IST OF F IGURES Figure 1: PW-6000 Connections, LEDs, and DIP Switches .............................. 7Figure 2: PW-6000 Power Terminals ............................................................... 13Figure 3: PW-600...
Page 6 - Table 1
PW-6000 Installation and Configuration Guide , Document 800-00005, Revision A vii L IST OF T ABLES Table 1 PW-6000 Jumper Settings .................................................................. 8 Table 2 PW-6000 DIP Switch Settings ............................................................ 9 T...
Page 8 - Notices; Warnings and Cautions; Before Installation; TURN OFF; Technical Specifications; after; Fire Safety and Liability Notice; an alternative exit
PW-6000 Installation Guide , Document 800-00005, Revision A 1 PW-6000 Installation 1 Notices 1.1 Warnings and Cautions Before Installation Warning: Before installation, TURN OFF the external circuit breaker which supplies power to the system. Before connecting the device to the power supply, verify ...
Page 9 - Earth Grounding; EARTH; ground all enclosures for proper installation.; Use Suppressors; Damage During Shipment; IF ANY DAMAGE TO THE SHIPMENT IS NOTICED, A CLAIM MUST; Electro Static Discharge; To prevent damage always follow these procedures:
2 www.honeywell.com PW-6000 Installation Notices Earth Grounding Warning: EARTH ground all enclosures for proper installation. Use Suppressors Warning: Use suppressors on all door strikes. Use S-4 suppressors for installation. Honeywell Integrated Security, Inc. recommends only DC strikes. 1.2 Damag...
Page 10 - Disclaimer – Product Liability Mutual Indemnification; filed with the commercial carrier.; Shipping Instructions; • A new purchase order number if the unit is not under warranty; Return Authorization Number
PW-6000 Installation Notices PW-6000 Installation Guide , Document 800-00005, Revision A 3 1.4 Disclaimer – Product Liability; Mutual Indemnification If a Customer receives a claim that a Product or any component thereof has caused personal injury or damage to the property of others, Customer shall ...
Page 11 - Limited Warranty; warranty; which must be completed and returned to Honeywell Integrated; Confidentiality
4 www.honeywell.com PW-6000 Installation Notices Show the RMA number on all packages shipped. Packages, which are not marked with an RMA number will be refused at the factory and returned to you COD. Carefully pack the equipment for shipment. Use the original packing material whenever possible 1.7 L...
Page 12 - Product Overview; Pro-Watch Software Suite Guide; Ports 2
PW-6000 Installation Product Overview PW-6000 Installation Guide , Document 800-00005, Revision A 5 Customer shall not copy the design of any of the Products or use or cause to be used any Product design or related materials for its own benefit or for the benefit of any other party. The covenants co...
Page 13 - • Transactions are stored in 1 MB of battery-backed SRAM. The maximum
6 www.honeywell.com PW-6000 Installation Product Overview 2.3 Other • An on-board real time clock maintains the date and time, taking into account leap year and accounting for global time zones and daylight savings time changes. • The database for the system configuration and card holders are stored...
Page 15 - Setting Up the PW-6000 Hardware; Setting the Jumpers; Jumpers
8 www.honeywell.com PW-6000 Installation Setting Up the PW-6000 Hardware 3 Setting Up the PW-6000 Hardware The PW-6000 processor is configured with 12 jumpers and a set of 4 DIP switches. These jumpers/switches set up the port interface, end of line termination, and operating mode configuration. Ref...
Page 16 - Setting the DIP Switches; Table 2 PW-6000 DIP Switch Settings
PW-6000 Installation Setting Up the PW-6000 Hardware PW-6000 Installation Guide , Document 800-00005, Revision A 9 3.2 Setting the DIP Switches Dual In-line Package (DIP) switches are read when the system powers up, except where noted otherwise. The following table shows the setting options. Table 2...
Page 17 - User Configuration
10 www.honeywell.com PW-6000 Installation Setting Up the PW-6000 Hardware The PW-6000 DIP switches need to be set twice: 1. Configure the S4-S3-S2-S1 DIP switches to off-off-on-off to set the default TCP/IP address to 192.168.0.251. 2. Apply power to the panel to set the IP address. 3. Change the S4...
Page 18 - Technical Specifications; Table 3 PW-6000 Technical Specifications; Category; Primary Power; Cable requirements; Environmental; Specifications subject to change without notice.
PW-6000 Installation Setting Up the PW-6000 Hardware PW-6000 Installation Guide , Document 800-00005, Revision A 11 3.3 Technical Specifications Table 3 PW-6000 Technical Specifications Category Description WARNING: PW-6000 is manufactured for use in low-voltage, Class 2 circuits only. Primary Power...
Page 19 - Initialization; Table 4 PW-6000 Status LED Combinations During Initialization
12 www.honeywell.com PW-6000 Installation Setting Up the PW-6000 Hardware Caution: Locate the power source as close to this board as possible. Connect power with minimum of 18AWG wires. Note: POLARITY for 12 VDC power is important. Make sure the +12 VDC is connected to the terminal labeled +12V and ...
Page 20 - Run TimeSupplying Power to the PW-6000 Interface; Supplying Power to the PW-6000 Interface; Observe POLARITY on 12 VDC.; LED
PW-6000 Installation Setting Up the PW-6000 Hardware PW-6000 Installation Guide , Document 800-00005, Revision A 13 Run TimeSupplying Power to the PW-6000 Interface 3.5 Supplying Power to the PW-6000 Interface The processor accepts 12Vdc for power. Locate power source as close to the unit as possibl...
Page 21 - Communications Wiring; Figure 4: PW-6000 TMP and FLT Terminals; Memory and Real Time Clock Backup Battery
14 www.honeywell.com PW-6000 Installation Setting Up the PW-6000 Hardware 3.6 Communications Wiring The PW-6000 processor communicates to the host via on-board Ethernet 10Base-T/100Base-TX port or on port 1. Port 1 may be configured as RS-232, two-wire RS-485 or optional Lantronix Ethernet 10Base-T/...
Page 22 - System Configuration via Web Interface; Connecting to ACDSM for the First Time; Figure 5: PW-6000 Web Server Login Screen
PW-6000 Installation System Configuration via Web Interface PW-6000 Installation Guide , Document 800-00005, Revision A 15 4 System Configuration via Web Interface The PW-6000 comes with Access Control Device Server Manager (ACDSM) . The ACDSM is a built-in web server, through which you can configur...
Page 23 - Page; Figure 6: PW-6000 Web Server Home Page
16 www.honeywell.com PW-6000 Installation System Configuration via Web Interface 4.3 Hom e Page The first screen after the login is the home page which displays all the available configuration links on the left navigation bar: Figure 6: PW-6000 Web Server Home Page
Page 24 - Network Settings; Click the; Network; Figure 7: PW-6000 Web Server Network Settings Screen; option button and reserve an IP address for the MAC address,; Static IP; Dynamic IP Configuration Method; Dynamic IP; option button to select the Dynamic Host Configuration Protocol; OK
PW-6000 Installation System Configuration via Web Interface PW-6000 Installation Guide , Document 800-00005, Revision A 17 4.4 Network Settings Click the Network link on the navigation bar to display the Network Settings screen where you can select the appropriate option button for dynamic or static...
Page 25 - Static IP Configuration Method; information in the appropriate fields:; Host Port; IP Server Connection Type
18 www.honeywell.com PW-6000 Installation System Configuration via Web Interface Static IP Configuration Method 1. Click the Static IP option button to assign a static IP address, and enter the following information in the appropriate fields: • IP Address • Subnet Mask • Default Gateway 2. Click OK ...
Page 26 - Guide
PW-6000 Installation System Configuration via Web Interface PW-6000 Installation Guide , Document 800-00005, Revision A 19 1. From PW6000 Communication Address drop-down list, select one of the eight (0 to 7) available communication addresses for the PW-6000 board. Note: In the previous panels, this...
Page 27 - IP Client Connection Type
20 www.honeywell.com PW-6000 Installation System Configuration via Web Interface IP Client Connection Type Figure 9: PW-6000 Host Port Configuration Screen with IP Client Connection Note: The PW-6000 panel does not currently support an IP Client connection.
Page 28 - available
PW-6000 Installation System Configuration via Web Interface PW-6000 Installation Guide , Document 800-00005, Revision A 21 Serial-RS232, Serial-RS485, Serial-Modem, or Serial-CoBox Connection Types Figure 10: PW-6000 Host Port Configuration with Serial RS-232 Connection 1. From the PW6000 Communicat...
Page 29 - Device Information; Figure 11: PW-6000 Web Server Device HW Info Screen
22 www.honeywell.com PW-6000 Installation System Configuration via Web Interface 3. For the Alternate Host Port , make the following selections: a. Connection Type . If you choose to configure an alternate host port, and if you have selected Serial-RS232 for the primary host port, select IP Server f...
Page 30 - User Configuration; Users; Figure 12: PW-6000 Web Server User Info Screen; Adding a User; New Account; to display the new user account screen.
PW-6000 Installation System Configuration via Web Interface PW-6000 Installation Guide , Document 800-00005, Revision A 23 4.7 User Configuration Click the Users link on the navigation bar to display the User screen where you can add, edit, and delete user records: Figure 12: PW-6000 Web Server User...
Page 31 - to save the setting.; Editing a User; Restore Default Screen
24 www.honeywell.com PW-6000 Installation System Configuration via Web Interface 3. Specify the maximum period of time a session will remain open without user activity. If the period expires without user activity, the user is logged out. After specifying the time period, click Save Session Timer to ...
Page 32 - Apply Setting Screen; Apply Setting; Figure 14: PW-6000 Web Server Apply Setting Screen; Log Out
PW-6000 Installation System Configuration via Web Interface PW-6000 Installation Guide , Document 800-00005, Revision A 25 4.9 Apply Setting Screen Click the Apply Setting link on the navigation bar to apply the selected configuration values: Figure 14: PW-6000 Web Server Apply Setting Screen Click ...
Page 34 - Appendix A; PW-6000 Web Server and Pro-Watch Channels
PW-6000 Installation and Configuration Guide , Document 800-00005, Revision A 27 Appendix A PW-6000 Web Server and Pro-Watch Channels The PW-6000 web server’s host port configuration requires corresponding changes in the way the Pro-Watch’s channels are configured. The PW-6000 web server host ports ...