Honeywell PUB4024S - Manual

Honeywell PUB4024S

Honeywell PUB4024S – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
Page: / 24

Table of Contents:

  • Page 2 – SPYDER® BACNET® PROGRAMMABLE CONTROLLERS; ORDERING INFORMATION; General Specifications
  • Page 3 – BEFORE INSTALLATION; WARNING; Disconnect power supply before beginning wiring or; INSTALLATION; Mount Actuator onto Damper Shaft; IMPORTANT
  • Page 4 – Before Mounting Actuator onto Damper
  • Page 5 – Mount Controller; NOTE: The controller may be wired before mounting to a; Terminal blocks are used to make all wiring connections to the; dimensions in inches (mm) for PVB0000AS and
  • Page 6 – Panel Mounting; NOTE: The controller is designed so that the cover does; Air flow Pickup; Power
  • Page 7 – Power Budget
  • Page 8 – Wiring
  • Page 9 – Communications
  • Page 10 – Setting the MS/TP MAC address; Termination Resistors; NOTE: The controller does not provide any network bias-; Shield Terminating; DIP
  • Page 11 – Wiring Method; Electrical Shock Hazard.; Disconnect power supply before beginning wiring, or; NOTE: When attaching two or more wires to the same; Wiring Details
  • Page 12 – Table 7. Description of wiring terminal connections for; MS/TP MAC ADDRESS DIP SWITCHES
  • Page 15 – NOTE: Make sure to set the Configuration DIP Switch as
  • Page 19 – CHECKOUT; Step 1. Check Installation and Wiring; first
  • Page 20 – Step 3. Checkout Completion; CONTROLLER REPLACEMENT; Do not attempt to modify the physical or electrical; Disconnect power supply before beginning controller; Terminal Block Removal
  • Page 21 – Controller Replacement (PVB4024NS
  • Page 24 – Automation and Control Solutions; BACnet
Loading the manual

PRODUCT DATA

63-2689-05

Spyder

®

BACnet

®

Programmable Controllers

PRODUCT DESCRIPTION

The PUB and PVB controllers are part of the Spyder family.

These controllers are BACnet MS/TP network devices

designed to control HVAC equipment. These controllers

provide many options and advanced system features that

allow state-of-the-art commercial building control. Each

controller is programmable and configurable through software.

The Spyder BACnet controllers require the Spyder BACnet

Programmable Feature to be licensed in the WEBpro

workbench tool and the WEBS AX JACE Controller for

programming and downloading. The Spyder BACnet Models

are also available as Individually Licensed Controllers (ILC).

The ILC versions are identical in design and capability in every

detail except for the licensing. The Individual Licensing of the

Spyder ILCs (the License is built in) allows them to be

programmed and downloaded with any brand of the Niagara

Workbench or JACE controller. The Spyder ILCs are identified

with a suffix on the Part Number of -ILC. Example:

PUB6438S-ILC follows all the same Installation Instructions

information as the PUB6438S.

These controllers are for use in VAV (Variable Air Volume),

Unitary and advanced HVAC control applications. Each

controller has flexible, universal inputs for external sensors,

digital inputs, and a combination of analog and digital Triac

outputs. All the models are described in Table 1. The photo to

the left is the model PVB6436AS, which includes the actuator.

Table 1. Controller configurations.

Each controller communicates via an EIA-485 BACnet MS/TP communications network, capable of baud rates between 9.6 and

115.2 kbits/s.
Controllers are field-mountable to either a panel or a DIN rail.

Controller

Model

Programmable

Type

Universal

Inputs

(UI)

Digital

Inputs

(DI)

Analog

Outputs

(AO)

Digital

Outputs

(DO)

Velocity

Pressure

Sensor

(Microbridge)

Series 60

Floating

Actuator

PUB1012S

Unitary

1 0

1

2

NO

NO

PUB4024S

Unitary

4 0

2

4

NO

NO

PUB6438S

Unitary

6

4

3

8

NO

NO

PVB0000AS

VAV

0

0

0

0

YES

YES

PVB4022AS

VAV

4

0

2

2

YES

YES

PVB4024NS

VAV

4

0

2

4

YES

NO

PVB6436AS

VAV

6

4

3

6

YES

YES

PVB6438NS

VAV

6

4

3

8

YES

NO

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SPYDER® BACNET® PROGRAMMABLE CONTROLLERS; ORDERING INFORMATION; General Specifications

SPYDER® BACNET® PROGRAMMABLE CONTROLLERS 63-2689—05 2 ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number. If you have additional questions, need furth...

Page 3 - BEFORE INSTALLATION; WARNING; Disconnect power supply before beginning wiring or; INSTALLATION; Mount Actuator onto Damper Shaft; IMPORTANT

SPYDER® BACNET® PROGRAMMABLE CONTROLLERS 3 63-2689—05 BEFORE INSTALLATION The controller is available in three models (see Table 1). Review the power, input, and output specifications on page 2 before installing the controller. — Hardware driven by Triac outputs must have a minimum current draw, whe...

Page 4 - Before Mounting Actuator onto Damper

SPYDER® BACNET® PROGRAMMABLE CONTROLLERS 63-2689—05 4 Fig. 2. Damper with 90 degree CW rotation to open. IMPORTANT Mount actuator flush with damper housing or add a spacer between the actuator mounting surface and damper box housing. Before Mounting Actuator onto Damper Shaft (PVB0000AS, PVB4022AS a...