- Page 2 – SPYDER® BACNET® PROGRAMMABLE CONTROLLERS; ORDERING INFORMATION; General Specifications
- Page 3 – BEFORE INSTALLATION; WARNING; Disconnect power supply before beginning wiring or; INSTALLATION; Mount Actuator onto Damper Shaft; IMPORTANT
- Page 4 – Before Mounting Actuator onto Damper
- Page 5 – Mount Controller; NOTE: The controller may be wired before mounting to a; Terminal blocks are used to make all wiring connections to the; dimensions in inches (mm) for PVB0000AS and
- Page 6 – Panel Mounting; NOTE: The controller is designed so that the cover does; Air flow Pickup; Power
- Page 7 – Power Budget
- Page 8 – Wiring
- Page 9 – Communications
- Page 10 – Setting the MS/TP MAC address; Termination Resistors; NOTE: The controller does not provide any network bias-; Shield Terminating; DIP
- Page 11 – Wiring Method; Electrical Shock Hazard.; Disconnect power supply before beginning wiring, or; NOTE: When attaching two or more wires to the same; Wiring Details
- Page 12 – Table 7. Description of wiring terminal connections for; MS/TP MAC ADDRESS DIP SWITCHES
- Page 15 – NOTE: Make sure to set the Configuration DIP Switch as
- Page 19 – CHECKOUT; Step 1. Check Installation and Wiring; first
- Page 20 – Step 3. Checkout Completion; CONTROLLER REPLACEMENT; Do not attempt to modify the physical or electrical; Disconnect power supply before beginning controller; Terminal Block Removal
- Page 21 – Controller Replacement (PVB4024NS
- Page 24 – Automation and Control Solutions; BACnet
PRODUCT DATA
63-2689-05
Spyder
®
BACnet
®
Programmable Controllers
PRODUCT DESCRIPTION
The PUB and PVB controllers are part of the Spyder family.
These controllers are BACnet MS/TP network devices
designed to control HVAC equipment. These controllers
provide many options and advanced system features that
allow state-of-the-art commercial building control. Each
controller is programmable and configurable through software.
The Spyder BACnet controllers require the Spyder BACnet
Programmable Feature to be licensed in the WEBpro
workbench tool and the WEBS AX JACE Controller for
programming and downloading. The Spyder BACnet Models
are also available as Individually Licensed Controllers (ILC).
The ILC versions are identical in design and capability in every
detail except for the licensing. The Individual Licensing of the
Spyder ILCs (the License is built in) allows them to be
programmed and downloaded with any brand of the Niagara
Workbench or JACE controller. The Spyder ILCs are identified
with a suffix on the Part Number of -ILC. Example:
PUB6438S-ILC follows all the same Installation Instructions
information as the PUB6438S.
These controllers are for use in VAV (Variable Air Volume),
Unitary and advanced HVAC control applications. Each
controller has flexible, universal inputs for external sensors,
digital inputs, and a combination of analog and digital Triac
outputs. All the models are described in Table 1. The photo to
the left is the model PVB6436AS, which includes the actuator.
Table 1. Controller configurations.
Each controller communicates via an EIA-485 BACnet MS/TP communications network, capable of baud rates between 9.6 and
115.2 kbits/s.
Controllers are field-mountable to either a panel or a DIN rail.
Controller
Model
Programmable
Type
Universal
Inputs
(UI)
Digital
Inputs
(DI)
Analog
Outputs
(AO)
Digital
Outputs
(DO)
Velocity
Pressure
Sensor
(Microbridge)
Series 60
Floating
Actuator
PUB1012S
Unitary
1 0
1
2
NO
NO
PUB4024S
Unitary
4 0
2
4
NO
NO
PUB6438S
Unitary
6
4
3
8
NO
NO
PVB0000AS
VAV
0
0
0
0
YES
YES
PVB4022AS
VAV
4
0
2
2
YES
YES
PVB4024NS
VAV
4
0
2
4
YES
NO
PVB6436AS
VAV
6
4
3
6
YES
YES
PVB6438NS
VAV
6
4
3
8
YES
NO
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
SPYDER® BACNET® PROGRAMMABLE CONTROLLERS 63-2689—05 2 ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number. If you have additional questions, need furth...
SPYDER® BACNET® PROGRAMMABLE CONTROLLERS 3 63-2689—05 BEFORE INSTALLATION The controller is available in three models (see Table 1). Review the power, input, and output specifications on page 2 before installing the controller. — Hardware driven by Triac outputs must have a minimum current draw, whe...
SPYDER® BACNET® PROGRAMMABLE CONTROLLERS 63-2689—05 4 Fig. 2. Damper with 90 degree CW rotation to open. IMPORTANT Mount actuator flush with damper housing or add a spacer between the actuator mounting surface and damper box housing. Before Mounting Actuator onto Damper Shaft (PVB0000AS, PVB4022AS a...