Honeywell ML6294 - Manual
Honeywell ML6294 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – ORDERING INFORMATION; Torque Ratings at Rated Voltages:
- Page 4 – INSTALLATION; WARNING; Mounting; CAUTION; Changing Hub Inserts.
- Page 5 – Actuator Damage Hazard.; Preparation
- Page 6 – mechanical connection.; WIRING; Electrical Shock Hazard.
- Page 7 – Transformer; Fig. 11. Common transformer with two controller outputs; OPERATION
- Page 8 – Fig. 13. Common transformer with one controller output; CHECKOUT
PRODUCT DATA
® U.S. Registered Trademark
© 2004 Honeywell International Inc.
All Rights Reserved
63-2511—1
ML6194, ML6294
Non-Spring Return
Direct Coupled Actuators
APPLICATION
The ML6194 and ML6294 Non-Spring Return Direct Coupled
Actuators (DCA) provide floating single-pole, double-throw
(spdt) control of dampers or valves in heating, ventilating, and
air conditioning (HVAC) applications. The ML6294 has an
internal, electrically isolated feedback potentiometer that can
be used to provide indication of motor output hub position or
slave a Series 90 actuator.
FEATURES
• Mount directly on 1/2 in. to 3/4 in. (13 to 19 mm) round
or square shaft. Mount on 1 in. (26 mm) round shafts
with appropriate insert. All models shipped with 1 in.
insert.
• 300 lb-in. (34 N•m) torque.
• Magnetic coupling eliminates need for mechanical
stops or limit switch adjustments by limiting stall
torque, which is dependent on temperature. Nominal
stall torque at room temperature of 68°F (20°C) is 410
lb-in.
• 95° stroke provides necessary compression of
rubber/neoprene gaskets commonly used on 90° low
leakage dampers.
• Declutch feature allows manual adjustment.
• 165 second synchronous timing can eliminate need for
feedback position indication in closed-loop
temperature control applications.
• Both single-point and three-point mounting
compatibility to allow installation flexibility.
• Models available with or without time-out feature.
Contents
Application ........................................................................
Features ...........................................................................
Specifications ...................................................................
Ordering Information ........................................................
Installation ........................................................................
Wiring ...............................................................................
Operation ..........................................................................
Checkout ..........................................................................
Troubleshooting ................................................................
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
ML6194, ML6294 NON-SPRING RETURN DIRECT COUPLED ACTUATORS 63-2511—1 2 ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number. If you have additional quest...
ML6194, ML6294 NON-SPRING RETURN DIRECT COUPLED ACTUATORS 63-2511—1 4 Device Weight: 3.0 lb (1.36 kg). Noise Rating: 45 dBA maximum at 1 meter. Position Indicator: Mounted on actuator hub. Actuator Design Life: Full Stroke Cycles: 50,000. Repositions: 1,500,000 minimum. Approvals: Underwriter’s Labo...
ML6194, ML6294 NON-SPRING RETURN DIRECT COUPLED ACTUATORS 5 63-2511—1 Fig. 3. Installing mounting bracket on ML6194/ML6294 Non-Spring Return DCA. A typical actuator mechanical connection is shown in Fig. 5; see Fig. 6 through 13 for wiring diagrams. CAUTION Actuator Damage Hazard. Using actuator as ...