Page 2 - Table of Contents
Table of Contents General Information ....................................................................................................................................................... 1 Package Contents ..............................................................................................
Page 3 - General Information; Package Contents; NOTE; Operation; UL Compliance
1 General Information The HWF2-COM Commercial Fire Communicator (henceforth referred to as HWF2-COM) is a commercial Fire Alarm commu- nicator that allows a Fire panel that previously reported by POTS to be upgraded to a system that uses the internet or cellular means to connect to a central station...
Page 4 - Programming for UL864 Compliance; STEP 1 – Determine the Signal Strength and Select a Location; RF Exposure; transmitter product procedures.
2 Programming for UL864 Compliance The HWF2-COM Commercial Fire Alarm Communicator provides a programmable supervision feature that allows the system to meet the UL864 Commercial Fire requirements. These requirements are in the following table. NOTICE TO USERS, INSTALLERS, AUTHORITIES HAVING JURISDI...
Page 5 - STEP 2 – Mount and Wire; In this step DO NOT plug the transformer in.
3 STEP 2 – Mount and Wire • For UL compliant installations, refer to the topic on UL Compliance in this manual. • For UL compliant installations, the Telco line wiring and the Power Transformer wiring must be routed through conduit. • For Dry/Indoor use only. • Unless otherwise specified, use 18AWG....
Page 7 - Register the Module; Choice
5 STEP 3 – Program the Communicator The HWF2-COM requires an AlarmNet account. For new installations, please obtain the account information from the central station prior to programming. You can program the communicator by one of the following methods: • Using the AlarmNet 360 website. • Using the 7...
Page 8 - This prompt appears only if comm. path includes IP&Cell or IP.; Display; Setting Factory Defaults
6 10. IP Flt Time (60 mins) NOTE: Refer to table above for correct default values. This prompt appears only if comm. path includes IP&Cell or IP. Enter the time delay (1 – 60) in minutes before the communicator notifies the con- trol panel that there is a communication path failure to AlarmNet o...
Page 9 - STEP 4 – Register the Communicator with AlarmNet; can register by using one of the following methods:; Registering through the AlarmNet 360 Website; registration process.
7 STEP 4 – Register the Communicator with AlarmNet Once you have programmed the communicator, it must be registered to enable the AlarmNet account. Registering the communicator activates the account with AlarmNet and enables the security system's control panel to send reports. You can register by us...
Page 10 - Possible Errors; ing an existing communicator; Replacing an existing communicator
8 Possible Errors Registration BAD Timed Out Displayed if no response to the registration request is received. Registration BAD Pri Sub ID BAD Indicates the city, central station, or customer number for the labeled account(s) is not accepted. The ID information was either entered in- correctly, or t...
Page 11 - Register by Phone; You will need the following information:; STEP 5 – Configure the Fire Panel; ate the high-low tones at an incorrect moment.; STEP 6 – Test the System; that these events were received.
9 Registration BAD If you entered an invalid PIN, the appropriate message is displayed depending on which account number is being replaced (see above for exact wording). The registration process is repeated. NOTE: Each attempt causes a substitution alarm to be sent to the cen- tral station. Register...
Page 13 - Programmer Keyboard Commands; nated in red on the 7720P Programming Tool.); Identification Displays
11 Programmer Keyboard Commands Programmer keyboard commands can be used to quickly view your connectivity settings and options. Most commands require you to press the [Shift] key and then the designated command key. (See the keys desig- nated in red on the 7720P Programming Tool.) [A] HWF2V-COM x.x...
Page 14 - AES
12 NOTE : The following displays except Encryption Test are displayed only if the communication path includes IP. [D] Physical Link Good/Bad Network Diagnostics Display Indicates whether the device has detected a physical connection to the internet. Press the [Space] key to go to the next field. NIC...
Page 15 - LTE Displays
13 LTE Displays RAT RSRP RSRQ LTE xxxx xxxx Signal Display for LTE RAT – Radio Access Technology. RSRP – Reference Signal Received Power RSRQ – Reference Signal Received Quality Press the [space] key to get to the next screen. Press the [backspace] key to go to the previous field. RSRP MIN MAX xxxx ...
Page 16 - Operating with 3G service (Applies to HWF2A ONLY); Signal Display for 3G; Testing Gateway; Run Network Diagnostic Test; Performs a set of network diagnostics that tests the integrity of
14 [E] Operating with 3G service (Applies to HWF2A ONLY) RAT RSCP EC/No 3G -xxx -xxxxxx Signal Display for 3G RAT – Radio Access Technology. RSCP –Received Signal Code Power Ec/N0 – Carrier Noise Ratio (CNR) Press the [space] key to get to the next screen. Press the [backspace] key to go to the prev...
Page 17 - System Status Displays; registered
15 System Status Displays [S] ECP Flt OK ECP Mode Displays system fault status. • Flt : Represents radio faults • OK : Normal, No fault o I : No network connectivity over IP and fault time has expired o i : No network connectivity over IP and fault time has NOT yet expired. o G : No network connecti...
Page 18 - Running Network Diagnostics; (available only if the communication path includes IP)
16 Running Network Diagnostics (available only if the communication path includes IP) The network diagnostic process tests the integrity of the links between the communicator and the various connection points of AlarmNet Control that are known as "Redirects" (Redirs or RDR). To initiate the ...
Page 19 - Possible Errors Running Network Diagnostics; tance Center (TAC) for help regarding any errors NOT listed below:
17 Possible Errors Running Network Diagnostics Errors may occur either while tracing the connection to a given Redir or while testing the service at a given Redir. The following list highlights the most common errors. Please contact the AlarmNet Technical Assis- tance Center (TAC) for help regarding...
Page 20 - Cyclical flashing – normal communications.
18 PowerBoost1 Information LED Indicator STATUS AC (green) AC power available. ACTIVE (green) Cyclical flashing – normal communications. Repetition of 3 flashes – loss of communications. LOW BATT (yellow) Missing or low battery. TROUBLE (yellow) One or more trouble conditions exist, such as; overloa...
Page 21 - Communicator Information
Page 22 - RF Specifications; Central Station Messages; Alarm Condition; Alarm Code; AlarmNet Messages
20 RF Specifications Frequency Bands LTE Band 2 LTE Band 4 LTE Band 5 LTE Band 12 LTE Band 13 WCDMA Band II WCDMA Band V HWF2V X X X HWF2A X X X X X X X Output Power LTE Class 3 23dBm WCDMA Class 3 24dBm IMPORTANT NOTE ABOUT EXTERNAL ANTENNAS Antenna may only be installed or replaced ONLY by a profe...
Page 23 - HWF2-COM Trouble Detection Information; Fault Condition; Indication to Fire Panel; HWF2-COM Specifications; ITEM
21 HWF2-COM Trouble Detection Information Telco 1 is used for the Fire Panel to output contact ID messages to the HWF2-COM, and Telco 2 is used by the HWF2-COM to report faults to the Fire Panel. If Telco 1 is not operational, the Fire Panel will use Telco 2 to report events if there are no faults i...
Page 24 - NOTES
Page 27 - routed in the same manner as the original factory wire. (
25 The wiring diagram below is depicted for point-to-point electrical connection checks used for troubleshooting or component replacement. It is not intended to show the physical routing of wires. When replacing a wire or component, ensure the wire is routed in the same manner as the original factor...
Page 28 - accordance with FCC multi-transmitter product procedures.
FEDERAL COMMUNICATIONS COMMISSION STATEMENTS The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Man- ual. Unauthorized changes or modifications could void the user's authority to operate the equipment. CLASS B DIGITAL DE...