Galaxy 3 Series Installation Manual Table of Contents i Contents Introduction ............................................................................................. 1-1 Variants ................................................................................................................ 1-...
Page 7 - Galaxy 3 Series Installation Manual; Galaxy 3 Series Programming Manual; Variants; Introduction
1-1 Galaxy 3 Series Installation Manual Introduction This manual gives full instructions required to install a Galaxy 3 Series control panel and associatedperipherals.Throughout this Installation Manual, references to menu options, unless otherwise indicated, are found in the Galaxy 3 Series Program...
Page 9 - Section 1: Quick Setup; AB LINE; Quick Setup
1-3 Galaxy 3 Series Installation Manual Section 1: Quick Setup To quickly set up a Galaxy 3 Series control panel for programming follow these simple steps: 1. Connect a 1k Ω (1%) resistor across each of the zones on the panel and any RIO’s (if connected). 2. Ensure that the tamper return loop — the ...
Page 11 - Section 2: System Architecture
Galaxy 3 Series Installation Manual 2-1 Section 2: System Architecture G3-48 Configuration Figure 2-1. Galaxy 3-48 System Configuration 16 zones on board Galaxy 3-48 Line 1 Keypads (8) CP027/Keyprox (3)CP028 8 zones 4 outputs RIO (4)C072 8 zones 4 outputs OR NOTE:The Telecom, Printer Interface, RS23...
Page 14 - PCB Layout
Galaxy 3 Series Installation Manual 2-4 PCB Layout PCB Layout Figure 2-4. PCB Layout LID T AMP +12V +12V +12V +12V 1 2 3 4 2 AU X T AMP G N D RX TX B2 A2 A1 B1 +12V PHONE LINE A B A B AC MICR O PR OCESSOR T elecom S o cke t 16 on-board z ones Exter nal loudspeak er Leads f o r lid tamper micros w it...
Page 15 - Table 2-1. SW3 Transistorised Outputs Control; line from the previous; AB; ) line must have a 680 ohm resistor fitted across the; RS485 Expansion Module
Galaxy 3 Series Installation Manual 2-5 The 7 transistorised outputs on the Galaxy 3 Series can be configured to open collectors by setting the dipswitch SW3 to the OFF position. NOTE: Output 2 on RIO 0 (relay output) is not affected. The following table shows which outputs are controlled by which s...
Page 16 - System Installation and Wiring; WARNING; Installation Recommendations
Galaxy 3 Series Installation Manual 2-6 System Installation and Wiring The installation and wiring must be performed by a competent engineer. For permanently connected equip-ment, a readily accessible disconnect device must be incorporated in the fixed wiring having contact separationof at least 3 m...
Page 17 - Connecting the Galaxy 3 Series to the PSTN; The Telecommunications Network Voltage (; ), then the connection can be carried out by the; , then the network operator must make the; System Wiring; Figure 2-7. Connecting the Galaxy 3 Series to the PSTN; Method 1
Galaxy 3 Series Installation Manual 2-7 Connecting the Galaxy 3 Series to the PSTN The Telecommunications Network Voltage ( TNV ) port (terminals A and B on PCB) must be permanently connected (hard-wired) to the PSTN via a BT master socket, refer to Figure 2-7.Note: If the BT master socket is the ne...
Page 18 - Connecting Additional Telecom Apparatus
Galaxy 3 Series Installation Manual 2-8 Connecting Additional Telecom Apparatus A BT secondary socket, allows additional telecom apparatus to be connected in series with the on-boardtelecom module. Connect the PHONE terminals A and B on the PCB to the terminals on the BT secondarysocket. See Figure ...
Page 19 - The system can be powered up via the; On-Board Power Supply Unit; Power Monitoring Characteristics:; The PSU is available for zones/outputs and peripherals.
Galaxy 3 Series Installation Manual 2-9 Stand-by Battery The Galaxy 3 Series control panels can accommodate up to 2 x 17 Ahr batteries. Ensure that the batteryconnector leads on the control panel Powers Supply Unit (PSU) are connected to the correct terminals on thebattery. CAUTION: There is a risk ...
Page 20 - warm start; RS485 Wiring Configurations; must; Memory
Galaxy 3 Series Installation Manual 2-10 Figure 2-8. Daisy Chain Configuration Memory The Galaxy 3 Series control panel is fitted with a memory chip with its own battery backup on the main PCB.This allows the panel to retain the system configuration, programming details and the event log for up to a...
Page 21 - RS485 Wiring Recommendations; RS485 Recommendations
Galaxy 3 Series Installation Manual 2-11 2. The system must be wired in a daisy-chain configuration. Spur and star configurations must not be used as they reduce the immunity to electrical interference. 3. The cable used to connect the RS485 ( AB ) line must be screened twisted pair (Part No. W002 )...
Page 22 - AB connectors
Galaxy 3 Series Installation Manual 2-12 RS485 Recommendations 6. There must only be a single AB pair of wires in each of the cables. 7. The minimum voltage level is 10.5 Vd.c. with 12.5 Vd.c. being the recommended working minimum. 8. The power supply in the Galaxy control panel and remote power sup...
Page 23 - Zones; Each zone has a four digit address; Zone Addresses; Galaxy
Galaxy 3 Series Installation Manual 2-13 Zones The default setting for the zones on the Galaxy 3 Series are shown in the following table: Table 2-6. Default Zone Functions Zone Addresses Each zone has a four digit address; 1004 , 4136 . The address is made up of three reference numbers as shown in t...
Page 24 - Wiring Zones; Galaxy 3 Series Programming; Zone Addressing with Onboard RIO Switch; The RIO switch is not functional on the 3-48. It defaults to the; Switch off; Switch on; Onboard RIO1; RIO Switch
Galaxy 3 Series Installation Manual 2-14 Table 2-8. Double Balanced ZoneResistance and Conditions Table 2-7. Zone Address Ranges Wiring Zones The zones on Galaxy 3 Series panels can be Double Balanced (default) or End of Line. Zones can be pro-grammed with different resistance ranges for zone status...
Page 25 - Wiring Keyswitches; Wiring Multiple Zones
Galaxy 3 Series Installation Manual 2-15 Figure 2-12. Preset 1 - Double balanced Zone/Detector wiring Zone Wiring NOTE: N/C = Normally Closed NOTE: The recommended maximum cable run from a zone to a detector is 500 metres. Wiring Keyswitches Latching or spring loaded keyswitches can be used to set a...
Page 26 - Outputs; Figure 2-15. Terminator and Keyswitch Zone Wiring; Wiring Terminator Buttons; Zones programmed as; Terminator Zone Wiring
Galaxy 3 Series Installation Manual 2-16 Outputs The Galaxy 3 Series control panel on-board outputs are detailed in the following table: Table 2-10. Outputs Figure 2-15. Terminator and Keyswitch Zone Wiring Wiring Terminator Buttons Zones programmed as Push-Set (terminator) buttons can be open going...
Page 27 - Figure 2-16. Output Configuration and Typical Applications; The polarity of each output can be changed using option; Output Applications
Galaxy 3 Series Installation Manual 2-17 Figure 2-17. Single Pole Change–Over Relay Output Configuration and Typical application Figure 2-16. Output Configuration and Typical Applications Output Applications The outputs on the Galaxy panels, with the exception of the SPCO relay output, are transisto...
Page 28 - Galaxy 3 Series; SPI Header
Galaxy 3 Series Installation Manual 2-18 SPI Header The Serial Peripheral Interface (SPI) header on the Galaxy 3 Series PCB allows copying and overwriting ofprogramming information between panels using the SPI key.The information is stored in a version independent format which allows panels of diffe...
Page 29 - Section 3: Optional Modules and Facilities; Addressing; The Galaxy RIO; be given a unique address; before; it is connected to a power supply. This; RIOs
Galaxy 3 Series Installation Manual 3-1 Section 3: Optional Modules and Facilities Remote Input Output (RIO) Modules – C072 Galaxy RIO’s can be added to the Galaxy 3-144 and 3-520 control panels. Each additional RIO expands thesystem by eight zones and four outputs. Table 3-1. Valid RIO Addresses Fi...
Page 30 - Connecting the RIO; XX Mod Added; if; INTRUDER; Configuring the RIO
Galaxy 3 Series Installation Manual 3-2 Connecting the RIO The RIO can only be connected to the system while engineer mode is accessed. The RS485 ( AB ) line of the Galaxy RIO must be wired in parallel (daisy-chain configuration) with the RS485 ( AB ) line of any keypads connected to the system. The...
Page 31 - Slave; RIO Outputs
Galaxy 3 Series Installation Manual 3-3 Outputs The RIO has four transistorised outputs. Each output is connected to +12 V via a 3k3 Ω pull-up resistor (refer to Table 3-3). When an output is activated, the load is switched to the negative supply voltage (groundor 0 V) of the RIO. The current availa...
Page 33 - Features; RF RIO
Galaxy 3 Series Installation Manual 3-5 RF RIO – C076 The Galaxy Radio Frequency (RF) RIO module is an optional add-on to the existing Galaxy product range.The module acts as an RF receiver for the Ademco 868MHz transmitter range. Features The RF RIO contains the following features: • Support for up...
Page 34 - Table 3-6 RF RIO Connections; RF RIO Tamper; Address Ranges
Galaxy 3 Series Installation Manual 3-6 Table 3-6. RF RIO Connections Note: If the RF RIO is the last Module on the line, connect a 680 Ω resistor across the A and B terminals. Outputs The RF RIO has four transistorised outputs. Each output is connected to +12 V via a 3k3 Ω pull-up resistor (refer t...
Page 35 - RF RIO Programming; Note; To program RF devices, please refer to; RF RIO Module, Installation and Programming; supplied with the RF RIO.; Configuring the RF RIO; the
Galaxy 3 Series Installation Manual 3-7 addresses are disabled by default. Module status on the RF RIO such as lid tamper,will be reported to the panel using the address set on therotary switch. RF RIO Programming Programming of the RF RIO is achieved by connecting a Galaxy Mk7 keypad directly to th...
Page 36 - The Galaxy Output Module must be given a unique address; it is connected to a power supply. This; NOTE
Galaxy 3 Series Installation Manual 3-8 Output Module Output Module – C078 Galaxy Output Modules can be added to the Galaxy 3 Series control panels. Each additional Output Moduleexpands the system up to 16 outputs by simulating the outputs of four RIO’s The following figure shows the main components...
Page 37 - Connecting the Output Module; Connecting Outputs
Galaxy 3 Series Installation Manual 3-9 Output Module (cont’d) Table 3-10. Output Module DIP Switch Settings Connecting the Output Module The Output Module can only be connected to the system while engineer mode is accessed. The RS485 ( AB ) line of the Output Module must be wired in parallel (daisy...
Page 38 - Assigning Outputs; Table 3.11 Output Assigning; Configuration Jumpers; M O D E; and; T E S T
Galaxy 3 Series Installation Manual 3-10 Output Module (cont’d) Output Signal Change The Output Module has one output which is used for warning about a change of state of any output. This iscontrolled by the BUZZER jumper. The following table shows the possible settings. Jumper Setting Output Functi...
Page 39 - Technical Specification - Output Module; Technical Specification - Relay Module; Operating temperature:; Relay Module
Galaxy 3 Series Installation Manual 3-11 Technical Specification - Output Module Output Module (boxed)Dimensions: Breadth: 162 mmLength: 150 mmHeight: 39 mm Operating temperature: -10 deg. C to +40 deg. C Operating voltage: 10.5V dc to 15V dc Current consumption: Quiescent: 45mAMaximum: 250mA (with ...
Page 40 - Power Supply Unit; Galaxy Power Unit; is a 3 ampere power supply. The; Galaxy Power RIO; is a Power Unit plus an on-; Configuration; Battery Low or Battery Fail condition.
Galaxy 3 Series Installation Manual 3-12 Figure 3-5. Power Supply Unit Power Supply Unit Power Supply Unit The Galaxy 3 Series Power Supply Unit is available in 2 variants.The Galaxy Power Unit is a 3 ampere power supply. The Galaxy Power RIO is a Power Unit plus an on- board Remote Input Output (RI...
Page 41 - The mains cable must satisfy the requirements stated in BS6500.; Installation Instructions
Galaxy 3 Series Installation Manual 3-13 Power Supply Unit (cont’d) Figure 3-6. Enclosure Base 2. Secure the panel base to the wall using three 1.5" No. 8 round head steel screws through the holesprovided. The mains cable used must be a three core type (with green/yellow earth insulation) of ade...
Page 42 - Battery; Electrical; (based on 34 Ah battery and UK grade 3 compliance); Fuses
Galaxy 3 Series Installation Manual 3-14 Battery The minimum capacity battery to supply the PSU is 1x 7Ah. The maximum capacity battery to supply thePSU is 2 x 17Ah. Battery Test A battery test on full load is automatically performed once an hour and during the Engineer Mode exitingprocedure. If the...
Page 43 - 5 way sub D type RS232 serial connector (part number; pin DIN plug (part number; have a serial interface port. The printer protocol; Printer Interface; Protocol
Galaxy 3 Series Installation Manual 3-15 Table 3-13. Printer Protocol Settings Printer Interface Module-A134/A161 The Printer Interface module allows the Galaxy to be connected to a serial printer and the contents of theevent log and the programming details of the system to be printed out. The modul...
Page 44 - Telecom Module – E062; Connection to the PSTN; Telecom Module
Galaxy 3 Series Installation Manual 3-16 Telecom Module – E062 The Galaxy Telecom module is an optional add-on to the existing Galaxy product range. It is a highly intelligentand compact module, combining both digital communication capabilities and remote servicing facilities.The Telecom Module is c...
Page 45 - RS232 Module, Operating; Interface with a PC; RS232 Interface Module
Galaxy 3 Series Installation Manual 3-17 RS232 Interface Module - E054 The Galaxy RS232 module provides full duplex serial communication between Galaxy control panels and PCsor printers. For further information regarding the Galaxy RS232 Interface Module refer to RS232 Module, Operating Instructions...
Page 46 - Serial Printer Interface; Tables; for printer; Table 3-14. RS232 Module Printer Interface Protocol; DIP Switch; Baud Rate
Galaxy 3 Series Installation Manual 3-18 Serial Printer Interface The module can also operate as an interface to a serial printer. Refer to the following Tables for printer protocol settings. Table 3-14. RS232 Module Printer Interface Protocol Table 3-15. Baud rate DIP Switch Settings Printer Interf...
Page 47 - Full existing Galaxy Telecom Module functionality; Programming the ISDN Module; ISDN Module
Galaxy 3 Series Installation Manual 3-19 ISDN Module – E077 The ISDN Module is an optional add-on to the existing Galaxy product range. It connects directly to theGalaxy RS485 communication bus, allowing signalling and remote servicing over an ISDN network. TheISDN Module is housed inside the Galaxy...
Page 48 - Ethernet Module - E080; Ethernet Module; Configuring the Ethernet Module; Ethernet Module, Installation Instructions
Galaxy 3 Series Installation Manual 3-20 Ethernet Module - E080 The Ethernet Module is an optional add-on to the Galaxy 3-144 and 3-520 panels. It is a highly intelligent andcompact module, combining alarm signalling, remote servicing and integrated facilities over Ethernet LAN and/or WAN. The Ether...
Page 49 - Remote Servicing Suite; Event Monitoring; User Management Suite; Table 3-16. Galaxy PC Products and Order Codes; Optional Software Packages
Galaxy 3 Series Installation Manual 3-21 Remote Servicing Suite The Remote Servicing Suite contains two main applications:• Event Monitoring Software. • Galaxy Gold Remote Servicing Software. Event Monitoring Alarm Monitoring is an advanced, high performance software program that allows a PC to rece...
Page 51 - Section 4: The Galaxy Mk7 Keypad/KeyProx; General; Power Consumption
Galaxy 3 Series Installation Manual 4-1 Mk7 Keypad/KeyProx Section 4: The Galaxy Mk7 Keypad/KeyProx NOTE: References in the text to the Mk7 keypad also includes the KeyProx in this section. General The Galaxy Mk7 keypad/keyProx has the following features: • a 2 x 16 alphanumeric character backlit di...
Page 52 - ISDN, RS232 or Telecom modules respectively are fitted.; Keypad/KeyProx Installation Procedure; Connections to the terminals are:; Keypad Installation; Wiring the Keypad/KeyProx
Galaxy 3 Series Installation Manual 4-2 Addressing The valid addresses of the keypad on each of the Galaxy panels are shown on the following Table: Table 4-2. Valid Keypad/KeyProx Addresses It is possible to add additional keypads at any unused comms module addresses (B, C, D and E) as detailedin th...
Page 54 - Volume Control; Appendix F; Adding a Keypad/KeyProx to the System; MOD ADDED; Removing a Keypad/KeyProx from the System; KEYPAD XX — =REMOVE MODULE
Galaxy 3 Series Installation Manual 4-4 Adding/Removing Keypads Volume Control Where fitted, the Mk7 keypad/keyprox has a volume control switch marked VOL at the bottom right-handcorner of the pcb. Make sure the keypad/keyprox is powered up and adjust to the desired volume (+ or -)for buzzer functio...
Page 55 - Self Diagnostics; Keypad/KeyProx Operation; Number Keys
Galaxy 3 Series Installation Manual 4-5 Keypad Operation The number keys are used to enter the Personal Identification Number(PIN) which identifies users to the Galaxy and permits access to the systemoptions. The PIN Code is a 5 or 6 digit number. Self Diagnostics The keypad has a self diagnostic fe...
Page 56 - esc
Galaxy 3 Series Installation Manual 4-6 The # key is used : • as a toggle key, which enables or disables the programming features ofthe Galaxy options, for example, enabling the OMIT attribute of a zone, • to give additional information on the programming options, for examplepressing the # key while...
Page 57 - or; Power LED
Galaxy 3 Series Installation Manual 4-7 Keypad Operation (cont’d) Galaxy 3-520 The Galaxy 3-520 has more than eight groups; these are displayed on the keypad in blocks of eight groups.Press the A or B key to display each of the group blocks. Power LED The green power LED indicates the status of the ...
Page 58 - The Galaxy KeyProx; The MAX addressing function in option; not; required for keyprox units.; Operation
Galaxy 3 Series Installation Manual 4-8 Keyprox The Galaxy KeyProx General The KeyProx is a standard Mk7 keypad with a proximity card reader built in to the lower right corner. Thisallows users to set and unset the system, using proximity cards, rather than a pin. NOTE: The keyProx is not intended f...
Page 59 - Standalone; Galaxy 3; Installing the MAX; MAX
Galaxy 3 Series Installation Manual 5-1 Section 5: Door Control Module - MAX 3 Introduction The MAX 3 is a proximity reader access control device for a single door, which can also be used for setting and unsetting of your alarm control panel. The MAX 3 can be configured in one of two ways: Standalon...
Page 60 - Wiring the MAX; The MAX; Figure 5-2. Standalone Connection diagram
Galaxy 3 Series Installation Manual 5-2 Wiring the MAX 3 The MAX 3 unit can be connected to the control panel in one of two ways depending upon whether it is being used in an on-line or standalone configuration. The diagrams below provides details for both configurations.The MAX 3 relay is configure...
Page 61 - Configuring a MAX; Configuring MAX
Galaxy 3 Series Installation Manual 5-3 Configuring a MAX 3 Reader into the System MAX 3 readers can only be configured into the Galaxy system from engineer mode. Access engineer mode.Wire the MAX 3 as per the instructions given in Figures 5-1 or 5-2 The MAX 3 reader must be assigned as either an On...
Page 62 - Configuring as a Stand-Alone MAX
Galaxy 3 Series Installation Manual 5-4 Configuring as a Stand-Alone MAX 3 1. Ensure that the MAX 3 is connected to the Galaxy ( RS485 AB line ) and the MAX mode is enabled (option 63.2.1 = OPTIONS.MAX.MAX Mode ). 2. Select option 63.2.2 = OPTIONS.MAX.MAX Address and press the ent key; the Galaxy se...
Page 63 - Removing a MAX; Card-Held System Setting
Galaxy 3 Series Installation Manual 5-5 Removing MAX 3 Readers Removing a MAX 3 Reader from the System On-Line Mode 1. Access engineer mode. 2. Disconnect the MAX 3 reader ( AB line and power). 3. Exit engineer mode. 4. The message 1 MOD. MISSING — [<],[>] to View is displayed. 5. Press the A ...
Page 64 - Downloading the MAX; U S R 0 3 2 V a l i d
Galaxy 3 Series Installation Manual 5-6 Viewing MAX 3 Events MAX 3 Log The Galaxy system has a panel dependent event log for recording the MAX 3 activations. This log is shared by all readers on the system and operates on a first-in-first-out basis for overwriting events when the log is filled.To di...
Page 65 - Dual Access Cards; for programming details.; Table; . If a card belonging to one of these users is
Galaxy 3 Series Installation Manual 5-7 Dual Card Access/Focus Dual Access Cards If a user’s card number is assigned a *, then the card becomes Dual access. This means that it will not openthe door on its own; it needs another PIN or card as well. If the PIN belonging to the same user has a #assigne...
Page 67 - Figure A-1 MAX Wiring Details
Galaxy 3 Series Installation Manual A-1 Installation Instructions Appendix A : Door Control - MAX (MX01) Installation Instructions The MAX box contains the following: • MAX reader (P/N MX01 ), • MAX facia label (P/N 21_1627 ), • 10-way connector block. The MAX installation sequence is as follows: 1....
Page 68 - Mounting the MAX; Surface Mounting the MAX; The MAX is positioned with the 2 LEDs at the top of the module.; Flush Mounting the MAX; Using the template on the lid of the MAX flush mounting kit box (P/N
Galaxy 3 Series Installation Manual A-2 Mounting the MAX Attach the wired-up 10-way connector block to the pins on the rear of the MAX reader. Surface Mounting the MAX 1. If the wiring is not wall recessed, remove the appropriate knock-out (from the sides, top or bottomof the MAX). 2. Using the MAX ...
Page 69 - Configuring a MAX Reader into the System; Configuring a MAX Reader
Galaxy 3 Series Installation Manual A-3 Configuring a MAX Reader into the System MAX readers can only be configured into the Galaxy system from engineer mode. NOTE: When adding a MAX reader to a Galaxy panel ensure that there are no more than eight MAXreaders connected to the RS485 ( AB ) line. Wire...
Page 70 - Configuring as On-Line MAX; Configuring On-Line MAX
Galaxy 3 Series Installation Manual A-4 Configuring as On-Line MAX 1. Only if reprogramming an existing stand-alone MAX reader: • Put the MAX reader into the sleep mode (present the Void Master card then swipe twice with the Program Master card — LEDs 2 – 5 switch on. Refer to the MAX Installation a...
Page 71 - Removing a MAX Reader from the System; Stand Alone Mode; Programming Instructions for On-Line Readers; Removing MAX Readers
Galaxy 3 Series Installation Manual A-5 Keypad Group Restriction: To restrict the operation of the function only to groups that are common to both the card and the MAX, press the key when assigning groups to the MAX.This means that when a card with access to groups 1, 2 and 3 activates the MAX card ...
Page 72 - Open Timeout; Group Restriction; Operating Instructions
Galaxy 3 Series Installation Manual A-6 Operating Instructions (On-Line Modes) The MAX must be presented with a valid user card to allow access. Opening the door while LED 2 ison activates an alarm; the buzzer sounds and LED 1 flashes until the door is closed.Activating the egress switch allows the ...
Page 73 - Max Log; Viewing Max Events
Galaxy 3 Series Installation Manual A-7 Max Log The Galaxy system has a 1000 event log (500 for 3-48) for the recording the MAX activations. This log isshared by all readers on the system and operates on a first-in-first-out basis for overwriting events when thelog is filled.To display the events in...
Page 75 - The Galaxy Smart PSU can be connected to the Galaxy control panels; Grounding; For further information refer to; Galaxy Smart Power Supply Unit Installation Instructions
Galaxy 3 Series Installation Manual B-1 Appendix B: 3 Ampere Smart PSU - P015 Smart PSU The Galaxy Smart PSU can be connected to the Galaxy control panels . The Smart PSU integrates a three ampere power supply with an eight zone Galaxy RIO. This can be used in place of a standard RIO to over-come po...
Page 77 - Appendix C: Panel Comparisons; Panel Comparisons; Galaxy G3 Panel
Galaxy 3 Series Installation Manual C-1 Appendix C: Panel Comparisons Panel Comparisons * The Galaxy 520 requires an additional plug-on module in order to provide two additional RS485 lines. Galaxy G3 Panel 3-48 3-144 3-520* Zones (on board to max) 16 to 48 (16 on board) 16 to 144 (16 on board) 16 t...
Page 79 - Appendix D: Declaration of Conformity; Compliance and Approvals; CE; Standards, including all EN safety and EMC standards.; Approvals
Galaxy 3 Series Installation Manual D-1 Appendix D: Declaration of Conformity Compliance and Approvals The Galaxy 3 Series control panels are compatible with the relevant parts of the following standards: • PD6662:2003 Scheme for the application of European Standards for intruder alarmsystems. • EN5...
Page 80 - Public Switched Telephone Network (PSTN) approval; May have interworking difficulties.
Galaxy 3 Series Installation Manual D-2 Approvals (cont’d) EN50131 Compliance This product is suitable for use in systems designed to comply with PD6662:2004 and prEN50131-1: 2004/6 Security Grade: 3Environmental Class: IIPower Supply Type: A The built-in Telecom module is for Remote Servicing use o...
Page 81 - Appendix E: Specifications; Panel Specifications
E-1 Galaxy 3 Series Installation Manual Appendix E: Specifications Panel Specifications Mechanical (all variants) Enclosure (with PCB and transformer) Width: 440 mmHeight: 352 mmDepth: 88 mmWeight: 6.4 kg Physical space for batteries 2 x 17Ah Max (not suitable for 12Ah batteries) PCB only Width: 265...
Page 83 - Measured with no load on zone input
E-3 Galaxy 3 Series Installation Manual Table E-1 Current Consumption Note 1: Measured with no load on zone input Note 2: Not communicating Specifications (cont’d) PCBs Weight Order Code Galaxy RIO ............................................................................... ....... 92 g A158 Size...
Page 85 - Appendix F: Parts List Index; Parts List Index
Galaxy 3 Series Installation Manual F-1 Appendix F: Parts List Index Parts List Index P r o d u c t N a m e U K P a r t N o C o m m e n t s R e p l a c e m e n t P C B , s G a l a x y 3 - 4 8 C P C B A 3 4 8 - 0 1 G a l a x y 3 - 1 4 4 P C B A 3 0 4 - 0 1 G a l a x y 3 - 1 4 4 C P C B A 3 0 5 - 0 1 ...
Page 87 - Index
1-1 Galaxy 3 Series Installation Manual Index A Adding a Keypad/Keyprox to the System 4-4 Addressing 4-2 Addressing the RF RIO 3-6 Appendix A: Door Control (MAX ) A-1 Appendix B: 3 Ampere Smart PSU B-1 Appendix C: Panel Comparisons C-1 Appendix D: Declaration of Conformity D-1 Appendix E: Specificat...