PRODUCT DATA
Put Bar Code Here
68-0282-07
Y8150 Fresh Air Ventilation System,
W8150 Fresh Air Ventilation Control
APPLICATION
The Y8150 Fresh Air Ventilation System, W8150 Fresh Air
Ventilation Control provide fresh air to a home. The control
operates a fresh air intake damper and, when necessary,
activates the main HVAC blower to efficiently meet ASHRAE
ventilation rates.
FEATURES
• Designed to help meet local ventilation codes and
standards, including ASHRAE 62.2-2010 standard,
“Ventilation and Acceptable Indoor Air Quality in
Low-Rise Residential Buildings.”
• Microcontroller optimizes the air delivery schedule to
make efficient use of normal HVAC run times.
• Easy-to-use input dials allow customized ventilation
for each installation.
• Test mode that includes immediate feedback to
installer to confirm that air delivery requirements of
selected ventilation standard are being met.
• Economical supply-only ventilation; works with forced
air system.
• Can be used with other equipment, such as an HRV/
ERV, for balanced ventilation.
IMPORTANT
Please read these instructions and keep them in your
records.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Other Manuals for Honeywell Y8150
Summary
Y8150 FRESH AIR VENTILATION SYSTEM, W8150 FRESH AIR VENTILATION CONTROL 68-0282—07 2 SPECIFICATIONS Y8150 includes: W8150A Fresh Air Ventilation Control. EARD6 Fresh Air Damper. AT120B Transformer. Mounting hardware for control. Homeowner information label. W8150 includes: W8150 Fresh Air Ventilatio...
Y8150 FRESH AIR VENTILATION SYSTEM, W8150 FRESH AIR VENTILATION CONTROL 68-0282—07 4 INSTALLATION A fresh air duct and damper must be installed between the outdoors and the return side of the HVAC equipment. The W8150 control will be mounted near the HVAC system and wired between the thermostat and ...
Y8150 FRESH AIR VENTILATION SYSTEM, W8150 FRESH AIR VENTILATION CONTROL 5 68-0282—07 Installing fresh air damper, ducting, and control… 1. Disconnect power from HVAC system. 2. Install the weather hood, ducting, and damper following local practices. Be sure all duct and insulation seams are tightly ...