Honeywell Y8610U- Manual
Honeywell Y8610U– Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Y8610U Intermittent Pilot Retrofit Kit
- Page 3 – Igniter-Sensor Specifications
- Page 6 – PLANNING THE INSTALLATION; WARNING
- Page 7 – INSTALLATION; When Installing this Product...
- Page 8 – Shut Down Appliance
- Page 9 – Remove Thermocouple
- Page 10 – Install the Gas Control; Converting Between Natural and LP Gas; Install Adapters to Gas Control (if used); Bushings; Install Gas Control Piping
- Page 11 – Mount Gas Control
- Page 12 – Wire the System; CAUTION
- Page 13 – Connect Ignition Cable
- Page 14 – SETTINGS; ON
- Page 15 – Jumper; CHECKOUT; Step 4: Reset the Ignition Control Module.
- Page 16 – OPERATION; Trial for Pilot Ignition; OPERATING SEQUENCE
- Page 17 – TROUBLESHOOTING; Troubleshooting Sequence
- Page 19 – LED Status and Troubleshooting
- Page 21 – Troubleshooting Guide
- Page 22 – ANSI STANDARDS; Exhibit A
- Page 23 – Exhibit B
PRODUCT DATA
Put UPC Code Here
68-0291-03
®
Automatic Ignition Systems
ANSI Z21.20
Y8610U Intermittent Pilot Retrofit Kit
GENERAL
The Y8610U is a complete kit for converting conventional
standing pilot systems to intermittent pilot systems. It is used
on gas-fired atmospheric furnaces, boilers, and heating
appliances. Not for use on direct vent, induced draft, or power
burner equipment. Meets ANSI Z21.71 standard for automatic
intermittent pilot ignition systems on central furnaces and
boilers.
FEATURES
• Y8610U kits can be used with either natural or LP gas.
• The S8610U ignition control provides a 90 second
maximum ignition trial, shuts off, waits five minutes
nominal, then re-initiates the pilot ignition sequence. The
ignition trial, shutoff, and wait cycle repeat until the pilot
lights or the call for heat ends.
Each kit includes:
— S8610U Intermittent Pilot Module
— VR8304M Dual Valve Combination Gas Control
or
VR8204A Dual Valve Combination Gas Control
— 392431 Igniter-Sensor
— 394800-30 Ignition Cable
— 393691 Natural to LP Gas Conversion Kit
— Wiring Harness
— 393690-14 Straight Flange Kit (3/4 in.)
— Reducer adapters for gas control with VR8304M
— Installation hardware
Temperature Ratings:
— S8610U: -40°F to 165°F (-40°C to 74°C)
— VR8304M: -40°F to 175°F (-40°C to 79°C)
— VR8204A: 0°F to 175° F (-18°C to 79°C)
Intermittent Pilot Gas Ignition Control Module
• Uses flame rectification for flame sense
• Internal spark generator lights pilot gas; main burner lights
after pilot flame lights and proves
• 100% shutoff of pilot and main gas if burner fails to light
• Continuous retry ignition sequence prevents nuisance
lockouts
• Two LEDs indicate system status and flame signal strength
Gas Control Valve
• Straight through body pattern
• VR8304M capacity is 270 ft
3
/hr (7.6 m
3
/hr)
• VR8204A capacity with or without 1/2” x 3/4” adapter is
150 ft
3
/hr (4.2 m
3
/hr)
• Manual ON-OFF valve blocks gas flow into the gas control
when in the OFF position
• Two main automatic valves: one solenoid-operated, and
one a servo-operated diaphragm system
Igniter-Sensor
• Single electrode made of Kanthal provides both ignition
and flame sensing
• Rated for 1775°F (968°C) at electrode tip; 1250°F (677°C)
at ceramic insulator
Contents
General ............................................................................. 1
Specifications ................................................................... 2
Planning the Installation .................................................... 6
Installation ........................................................................ 7
Settings ............................................................................ 14
Checkout .......................................................................... 15
Operation .......................................................................... 16
Troubleshooting ................................................................ 17
Ansi Standards ................................................................. 22
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Other Manuals for Honeywell Y8610U
Summary
Y8610U INTERMITTENT PILOT RETROFIT KIT 68-0291—03 2 ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number. If you have additional questions, need further...
Y8610U INTERMITTENT PILOT RETROFIT KIT 3 68-0291—03 Transformer Sizing: Add current ratings of Y8610, vent damper, and any other control system components. Multiply this total by 24V to determine the transformer VA requirement. Mounting: Mounts in any position except with terminals up. Recom- mended...
Y8610U INTERMITTENT PILOT RETROFIT KIT 68-0291—03 6 Fig. 5. 392431 Igniter-sensor mounting dimensions in inches. (mm). PLANNING THE INSTALLATION WARNING Fire or Explosion Hazard. Can cause severe injury, death or property damage. 1. Plan the installation as outlined below. 2. Plan for frequent maint...