Honeywell CHRONOTHERM T8602C- User Manual

Honeywell CHRONOTHERM T8602C

Honeywell CHRONOTHERM T8602C– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – WIRING; CAUTION; Disconnect power before wiring.
  • Page 3 – IV DELUXE PROGRAMMABLE THERMOSTATS; Fig. 4. Typical hookup in heat and cool system; Mounting Thermostat; Press lower edge of case to close and latch.
  • Page 4 – Using Thermostat Keys; SETTINGS; System and Fan Settings; Temperature Settings; Period
  • Page 5 – FAN OPERATION SWITCH; Fig. 13. Display of Installer Setup number and; IMPORTANT; Return; Hold for
  • Page 8 – Setting Current Day and Time
  • Page 9 – INSTALLER SYSTEM TEST
  • Page 10 – THERMOSTAT INFORMATION; Press the Time; CHECKOUT; Outdoor Temperature Sensor
  • Page 11 – TROUBLESHOOTING GUIDE; Symptom
  • Page 12 – Verify operation of heating or cooling equipment in self-test.
Loading the manual

® U.S. Registered Trademark
Copyright © 2003 Honeywell •

• All Rights Reserved

INSTALLATION INSTRUCTIONS

69-1670

T8602C Chronotherm

®

IV

Deluxe Programmable

Thermostats

APPLICATION

The T8602 Chronotherm

®

IV Deluxe Programmable Thermostat provides electronic control of 24 Vac single-stage

heating and cooling systems or 750 mV heating system. Refer to Table 1 for a general description of the thermostat. All
T8602 thermostats are powered by batteries.

Table 1. Description of T8602 Thermostats.

MERCURY NOTICE

If this control is replacing a control that contains
mercury in a sealed tube, do not place your old
control in the trash. Dispose of properly.

Contact your local waste management authority
for instructions regarding recycling and the
proper disposal of the old control.

INSTALLATION

When Installing this Product...

1.

Read these instructions carefully. Failure to follow
the instructions can damage the product or cause
a hazardous condition.

2.

Check the ratings given in the instructions and on
the product to make sure the product is suitable for
your application.

3.

Installer must be a trained, experienced service
technician.

4.

After completing installation, use these instructions
to check out the product operation.

Location

Install the thermostat about 5 ft (1.5m) above the floor in
an area with good air circulation at average temperature.
See Fig. 1.

Do not install the thermostat where it can be affected by:
— drafts, or dead spots behind doors and in corners.
— hot or cold air from ducts.
— radiant heat from sun or appliances.
— concealed pipes and chimneys.
— unheated (uncooled) areas such as an outside wall

behind the thermostat.

Wallplate Installation

The thermostat can be mounted horizontally on the wall
or on a 2 in. x 4 in. (50.8 mm x 101.6 mm) wiring box.
Position wallplate horizontally on the wall or on a
2 in. x 4 in. (50.8 mm x 101.6 mm) wiring box.

T8602

System

Changeover

System Selection

Fan

Selection

Comments

C

Heat-Cool

Manual

Heat-Off-Cool

On-Auto

System and fan selections are made on
keyboard.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - WIRING; CAUTION; Disconnect power before wiring.

T8602C CHRONOTHERM ® IV DELUXE PROGRAMMABLE THERMOSTATS 69-1670 2 Fig. 1. Typical location of thermostat. 1. Position and level the wallplate (for appearance only). The thermostat functions correctly even when not level. 2. Use a pencil to mark the mounting holes. See Fig. 2. 3. Remove the wallplate...

Page 3 - IV DELUXE PROGRAMMABLE THERMOSTATS; Fig. 4. Typical hookup in heat and cool system; Mounting Thermostat; Press lower edge of case to close and latch.

T8602C CHRONOTHERM ® IV DELUXE PROGRAMMABLE THERMOSTATS 3 69-1670 Fig. 4. Typical hookup in heat and cool system with one transformer. Fig. 5. Typical hookup in heat and cool system with two transformers. Fig. 6. T8602 typical millivoltage heating circuit. . Fig. 7. Correct wiring technique. Mountin...

Page 4 - Using Thermostat Keys; SETTINGS; System and Fan Settings; Temperature Settings; Period

T8602C CHRONOTHERM ® IV DELUXE PROGRAMMABLE THERMOSTATS 69-1670 4 Using Thermostat Keys The thermostat keys are used to:• set current day and time,• program times and setpoints for heating and cooling,• temporarily override program temperatures, • display present setting, • configure Installer Setup...

Other Honeywell Models