Honeywell BC7000L1000- User Manual

Honeywell BC7000L1000

Honeywell BC7000L1000– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
Page: / 33

Table of Contents:

  • Page 2 – SECTION I
  • Page 3 – TO
  • Page 6 – SECTION II; FIREYE P-SERIES CONTROLS
  • Page 13 – SECTION Ill
  • Page 23 – SECTION IV
  • Page 29 – SECTION V
Loading the manual

CONVERSION WIRING DIAGRAMS

FOR

BC7000L1000

The diagrams and instructions contained in this booklet are for converting the following model

programmers to BC7000 Microcomputer Based Burner Control System.

TABLE OF CONTENTS

Page

Section l . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...2

Fireye C, D, and E-Series

Section II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...6

Fireye P-Series

Section III . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Honeywell R4126, R4127, R4181

Section lV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Honeywell R4140, R4150 with 20 Terminal Subbase (120 V only)

Section V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...29

Honeywell R4150 with 13 or 15 Terminal Subbase

1. Installer must be a trained, experienced, flame safeguard control service technician.

2. Disconnect power supply before beginning installation to prevent electrical shock and

equipment damage.

3. All wiring must comply with applicable local electrical codes, ordinances, and regulations.

4. Voltage and frequency of the power supply and flame detector(s) connected to this control

must agree with those marked on the device.

5. Loads connected to the control terminals must not exceed those listed in the SPECIFI-

CATIONS section.

6. All external timers must be listed or component recognized by authorities having

jurisdiction, for the specific purpose for which they are used.

7. Perform all required checkout tests after installation is complete.

IMPORTANT

For on-off, gas-fired systems, some authorities having jurisdiction prohibit the wiring of any

limit or operating contacts in series with the main fuel valve(s).

P.G.

Rev. 6/89

Form Number 66-6002—4

©Honeywell Inc. 1989

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Honeywell BC7000L1000

Summary

Page 2 - SECTION I

SECTION I FIREYE C, D, E-SERIES CONTROL 120 V ONLY DIRECTIONS: 1. Disconnect all power to programmer. 2. Remove old programmer from subbase (trade-in to Honeywell Authorized Flame Safeguard Distributor). 3. Mark all wires on subbase; i.e., wires connected to terminal “D” should be marked “D.” Discon...

Page 3 - TO

FIREYE 70D10/26CF6-5022/26 CU6-5065 EP160/EP161/EP170 TO BC7000L/PM720L2004 or 1030

Page 6 - SECTION II; FIREYE P-SERIES CONTROLS

SECTION II FIREYE P-SERIES CONTROLS 120 V ONLY DIRECTIONS: 1. 2. 3. 4. 5. 6. 7. 8. Disconnect all power to programmer. Remove old programmer from subbase (trade-in to Honeywell Authorized Flame SafeguardDistributor). Mark all wires on subbase; i.e., wires connected to terminal “D” should be marked “...

Other Honeywell Models