Honeywell 63-4526-01 - Manual

Honeywell 63-4526-01

Honeywell 63-4526-01 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
Page: / 36

Table of Contents:

  • Page 2 – PIR APPLICATION GUIDE FOR TB7200 AND TB7300 SERIES THERMOSTATS; OCCUPANCY SENSOR COVER MODELS
  • Page 3 – IMPORTANT THINGS TO KNOW; Hotel and Lodging Applications; Room Temperature
  • Page 4 – Fig. 1. Unoccupied timer set 6 Hours and stand-by timer set to 2 hours; pied timer is set; Fig. 2. Unoccupied timer set 0 Hours and stand-by timer set to 2 hours; unoccupied timer is set to its factory default value of 0.0 hours; Network Priority and Local Occupancy Routine:; Time
  • Page 6 – After Receiving the; Network Command From a Previous Unoccupied State; Local Occupancy / PIR; Network Command From a Previous Occupied State
  • Page 7 – TYPICAL COMMERCIAL APPLICATIONS
  • Page 8 – Sequence of operation:
  • Page 16 – Sequence of operation
  • Page 20 – TYPICAL LODGING APPLICATIONS
  • Page 33 – Typical PIR Detection Pattern; INSTALLATION; WARNING; the thermostat and its accessories.
  • Page 34 – TB-PIR Cover Installation; Remove security screw on the bottom of the thermostat cover.
  • Page 35 – PIR Status LED’s; SPECIFICATIONS; Vdc max current draw of 7mA
  • Page 36 – Automation and Control Solutions
Loading the manual

APPLICATION GUIDE

Put Bar Code Here

63-4526-01

PIR Application Guide for TB7200

and TB7300 Series Thermostats

PRODUCT OVERVIEW

This application guide provides application information and for

Honeywell TB7200 and TB7300 Series communicating

thermostats. When equipped with an occupancy sensor cover

or a remote PIR sensor (wired to one of the remote inputs),

these thermostats provide advanced active occupancy logic,

which automatically switches occupancy levels from Occupied

to Stand-by to Unoccupied as required by local activity being

present or not. TB7200 and TB7300 Series thermostats can

be ordered with an occupancy sensor cover or have one

added at a later time. All thermostats are PIR ready. The

occupancy sensor covers have an embedded, passive-infra-

red motion detector designed to work with TB7200 and

TB7300 thermostats. This advanced occupancy functionality

provides advantageous energy savings during occupied hours

without sacrificing occupant comfort.

APPLICATIONS

The range of applications covered with the PIR occupancy

logic can be segmented into two important categories in terms

of functionality. Both use different settings and have different

behaviors:

• Hotel and lodging applications

• Standard commercial applications

Typical applications include:

• Stand-alone lodging FCU applications

• Networked lodging FCU applications fully integrated to a

reservation system

• Networked or stand-alone conference rooms

• Networked or stand-alone classrooms units

• Any commercial offices that have random occupancy

schedules during occupied hours as dictated by the

function of the tenant

• Any controlled piece of HVAC equipment that may yield

energy savings with the introduction of a new automatic

stand-by level of occupancy.

MORE INFORMATION

The additional following documentation is available at Honey-

well Buildings Forum (

http://buildingsforum.honeywell.com

).

• TB7200 Installation Instructions (form number 62-2019)

• TB7300 Installation Instructions (form number 62-2018)

• Occupancy Sensor Cover for TB7200/TB7300/TB7600

Series Thermostats (62-2021)

• BACnet Integration Manual for TB7200 & TB7300 (form

number 63-4524) for detailed integration information.

• Wireless Reference Manual for TB7200, TB7300, and

TB7600 Series (form number 63-4522).

TB7300 Series

Thermostat with

Occupancy Sensor

Contents

Product Overview ............................................................. 1

Applications ...................................................................... 1

More Information .............................................................. 1

Occupancy Sensor Cover Models .................................... 2

Occupancy Sensing Configuration Parameters ................ 2

Important Things to Know ................................................ 3

Typical Commercial Applications ..................................... 7

Typical Lodging Applications ............................................ 20

Installation ........................................................................ 33

Specifications ................................................................... 35

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - PIR APPLICATION GUIDE FOR TB7200 AND TB7300 SERIES THERMOSTATS; OCCUPANCY SENSOR COVER MODELS

PIR APPLICATION GUIDE FOR TB7200 AND TB7300 SERIES THERMOSTATS 63-4526—01 2 OCCUPANCY SENSOR COVER MODELS OCCUPANCY SENSING CONFIGURATION PARAMETERS The following configuration parameters are specifically provided as standard on all TB7200 and TB7300 Series thermostats. They are associated with the ...

Page 3 - IMPORTANT THINGS TO KNOW; Hotel and Lodging Applications; Room Temperature

PIR APPLICATION GUIDE FOR TB7200 AND TB7300 SERIES THERMOSTATS 3 63-4526—01 IMPORTANT THINGS TO KNOW When reviewing the following document and planning an application using a Honeywell thermostat with PIR functionality, please remember the important following notes: • Configuration of PIR Functions:...

Page 4 - Fig. 1. Unoccupied timer set 6 Hours and stand-by timer set to 2 hours; pied timer is set; Fig. 2. Unoccupied timer set 0 Hours and stand-by timer set to 2 hours; unoccupied timer is set to its factory default value of 0.0 hours; Network Priority and Local Occupancy Routine:; Time

PIR APPLICATION GUIDE FOR TB7200 AND TB7300 SERIES THERMOSTATS 63-4526—01 4 • Unoccupied Timer Disable: In certain application cases, it may be desired to never let the local area enter the unoccupied mode and always stay at the stand-by occupancy level when no activity is present. This allows for a...