1-1. INTRODUCTION
This section provides troubleshooting information in the form
of an easy to read table.
If a problem occurs during the first operation of a new fryer,
recheck the installation per the Installation Section of this
manual.
Before troubleshooting, always recheck the operation pro-
cedures per Section 3 of this manual.
1-1
1103
SECTION 1. TROUBLESHOOTING
Where information is of particular importance or safety related,
the words DANGER, WARNING, CAUTION, and NOTICE are
used. Their usage is described below.
SAFETY ALERT SYMBOL is used with DANGER,
WARNING, or CAUTION which indicates a personal injury
type hazard.
NOTICE is used to highlight especially important information.
CAUTION used without the safety alert symbol indicates
a potentially hazardous situation which, if not avoided,
may result in property damage.
CAUTION indicates a potentially hazardous situation
which, if not avoided, may result in minor or moderate
injury.
WARNING indicates a potentially hazardous situation
which, if not avoided, could result in death or serious
injury.
DANGER INDICATES AN IMMINENTLY
HAZARDOUS SITUATION WHICH, IF NOT
AVOIDED, WILL RESULT IN DEATH OR SERIOUS
INJURY.
1-2. SAFETY
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Model 290 Problem Cause Correction POWER SECTION With switch in • Open circuit • Check to see that unit is POWER position, plugged in the fryer is com- • Check the breaker or fuse pletely inoperative at supply box (NO POWER) • Check voltage at wallreceptacle • Check MAIN POWERswitch; replace if defe...
Model 290 Problem Cause Correction HEATING OF SHORTENING SECTION (Continued) Heating of shortening • Low or improper voltage • Use a meter and check the too slow receptacle against data plate • Weak or burnt out element(s) • Check heating element(s) per Heating Elements Section • Points in contactor...
Model 290 1-4. ERROR CODES (Continued) CE Only - Along with the error codes from page 1-11, CEunits have the following self-diagnostic error codes: DISPLAY CAUSE PANEL BOARD CORRECTION “E10” High limit Reset the high limit by manually pushing up on the red resetbutton; if the high limit does not res...