Heath Zenith HB-4190 Series - Manual

Heath Zenith HB-4190 Series

Heath Zenith HB-4190 Series – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
Page: / 20

Table of Contents:

  • Page 2 – INSTALLATION; junction box; WIRING; One Motion Light; Black to black; Set sensitivity on; WARNING: Turn power off at circuit
  • Page 3 – OPTIONAL WIRING; This fixture is provided with a sensor rated; Wiring to Motion Light &
  • Page 4 – COMPLETE THE INSTALLATION; Model 4193 Glass Installation; COMPLETE THE; Stuff the wires into the junction box. Make
  • Page 5 – TESTING; Motion; SPECIFICATIONS; Avoid locations that will cause
  • Page 6 – TROUBLESHOOTING GUIDE; If you experience a problem, follow this guide.
  • Page 7 – FUNCIONAMIENTO; Características; PRUEBA; MODO MANUAL; Prueba
  • Page 8 – INSTALACION; Monte el soporte; Fije de nuevo el alcance; ADVERTENCIA: Desconecte la energía; LUZ DE ADORNO; Resumen de las modalidades del
  • Page 9 – CABLEADO; Luz de un movimiento; Negro to negro; Tuerza los cables de la caja de empalme; CUIDADO: NO conecte el cable ROJO
  • Page 10 – CONEXION ALTERNA; Este aparato viene con un detector con una; NOTA: Todo el cableado entre los aparatos; Conexión a la luz de movimento
  • Page 11 – COMPLETE LA INSTALACION; Instalación del vidrio del Modelo; COMPLETE LA; Meta los cables en la caja de empalme.; de 60 Vatios en estilo candelabro (Se; Después de completar la prueba de la; calafatee el aparato y la
  • Page 12 – NOTA: El detector tiene un período de cerca; ESPECIFICACIONES; Evite lugares que obliguen; ductos de calefacción
  • Page 13 – GUIA DE INVESTIGACION DE AVERIAS; Si tiene algún problema siga esta guía.
  • Page 14 – FONCTIONNEMENT; Note: Après mise en circuit, attendre enfiron; ESSAI; Essai
  • Page 15 – Réglez la sensibilité à; AVERTISSEMENT : Coupez le courant; Minuterie D; Résumé du mode de commutation
  • Page 16 – CÂBLAGE; AVERTISSEMENT: NE PAS raccorder le
  • Page 17 – CÂBLAGE FACULTATIF
  • Page 18 – COMPLÉTEZ L'INSTALLATION; Installation des panneaux de; COMPLÉTEZ; une ampoule de 100 W maximum,
  • Page 19 – ESSAIS; FICHE TECHNIQUE; NOTE: Le capteur doit se réchauffer 1; Éviter de pointer l’appareil:; Portée maximale Angle de couverture
  • Page 20 – GUIDE DE DÉPANNAGE; Si vous éprouvez des difficultés, suivre ce guide.
Loading the manual

Motion Sensing
Diecast Lantern

HB-4190 Series

Features

• Light comes on when motion is detected.
• Automatically turns light off.
• Dusk Accent lighting.
• Photocell keeps the light off during daylight

hours.

Requirements

• The light control requires 120 volts AC.
• If you want to use Manual Mode, the control

must be wired through a switch.

Some codes require installation by a
qualified electrician.

© 2008

595-5770-05

OPERATION

* resets to Auto Mode at dawn.

Set the ON-TIME switch
on the bottom of the cover
plate to

TEST.

TEST 1 5 10 MIN

Set ON-TIME switch to 1,
5 or 10 minutes.

1 Second

OFF

then

...

Manual mode only works at
night because daylight re-
turns the sensor to AUTO.
Flip the light switch off for
one second then back on to
toggle between AUTO and
MANUAL MODE.
Manual mode works only with
the ON-TIME switch in the 1,
5, or 10 position.

... back on.

Mode Switching Summary

D

ual

B

rite

®

Dimmer Control

Light comes on half bright for selected time
after dusk (3 hr., 6 hr., until dawn). If motion
is sensed, the light turns on full bright for the
ON-TIME (1, 5, or 10 minutes) then returns
to dim mode.

This package includes:
• Lantern
• Easy to use universal mounting bracket

(X-Bar)

• Mounting hardware
• Wire nuts
• Light Bulb(s)

ON-TIME Switch at 1,

5, or 10 minutes

Flip light switch

off for one second

then back on*

* If you get confused while switching modes,

turn the power off for one minute, then back
on. After the calibration time the control will
be in the AUTO mode.

MANUAL MODE

AUTO

TEST

Note: When first turned on wait about 1

1

/

2

minutes for the circuitry to calibrate.

TEST

AUTO

MANUAL MODE

TEST

1 5 10 MIN

Mode:

On-Time

Works: Day Night

Test

5 Seconds

x

x

Auto

1, 5, or 10 Min

x

Manual

To Dawn*

x

Accent

3,6 Hr. to Dawn

x

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - INSTALLATION; junction box; WIRING; One Motion Light; Black to black; Set sensitivity on; WARNING: Turn power off at circuit

2 595-5770-05 INSTALLATION For best performance, mount the fixture about 1.8 meters above the ground. 1. Remove two nuts. 2. Remove X-Bar. Junction Box 5. Attach X-Bar to junction box Due to the size and weight of the fixture, you may find it helpful to have an assistant hold the fixture in place wh...

Page 3 - OPTIONAL WIRING; This fixture is provided with a sensor rated; Wiring to Motion Light &

3 595-5770-05 ❒ When wiring to additional standard fixture only: Strip the motion sensor's red wire and connect to the standard light's black wire. Connect all white wires together. Total fixture ratings must not exceed 360 Watts (3.0 A.). NOTE: All wiring between fixtures should be run in accordanc...

Page 4 - COMPLETE THE INSTALLATION; Model 4193 Glass Installation; COMPLETE THE; Stuff the wires into the junction box. Make

4 595-5770-05 COMPLETE THE INSTALLATION Model 4193 Glass Installation ❒ Model 4193 only: install the six pieces of glass by sliding them down as shown. The glass panels should rest upon the corner guides on each side, and against the rubber bumpers at the bottom. Note: As with any glass, handle with...

Other Heath Zenith Models

All Heath Zenith Other