Heath Zenith CB-2010 - Manual
Heath Zenith CB-2010 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – INSTALLATION; Turn power off at the fuse or circuit breaker.; Wall Mount; Twist the junction box wires and fixture wires together
- Page 3 – TEST AND ADJUSTMENT; Bottom of Sensor; Areas where pets or traffic may trigger the con-; SPECIFICATIONS
- Page 4 – TROUBLESHOOTING GUIDE; YOUR HEATH/ZENITH 15 YEAR LIMITED WARRANTY
- Page 5 – FUNCIONAMIENTO; Prueba; PRUEBA; Cuando lo prenda por primera vez espere 1
- Page 6 – INSTALACION; CONECTE EL CONTROL DE LUZ
- Page 7 – PRUEBA Y AJUSTE; Lo menos sensible; ESPECIFICACIONES; Angulo de
- Page 8 – GUIA DE INVESTIGACION DE AVERIAS; SU GARANTÍA HEATH/ZENITH LIMITADA A 15 AÑOS
- Page 9 – x x; FONCTIONNEMENT; * Si vous ne savez plus dans quel mode se trouve
- Page 10 – Montage sous avant-toit; Montage de la Commande D’Éclairage; Couper l’alimentation du circuit d’éclairage au
- Page 11 – Rotule
- Page 12 – GUIDE DE DÉPANNAGE; VOTRE GARANTIE LIMITÉE DE 15 ANS HEATH/ZENITH
OPERATION
Model CB-2010
Motion Sensor
Light Control with
Protective Lamp
Shields
© 2000 Heath Co. a div. of DESA International
598-1090-00
* resets to Auto Mode at dawn.
TEST
Light Control
Sensor
Cover
Plate
Lamp
Holders
6 Screws
(3 sizes included)
Gasket
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
This package includes:
Requirements
•
The Light Control requires 120-volts AC.
•
If you want to use the Manual Mode, the control
must be wired through a switch.
•
Some codes require installation by a qualified
electrician.
•
This product is intended for use with the enclosed
gasket and with a junction box marked for use in
wet locations.
TEST 1 5 20
ON-TIME
Put ON-TIME switch on the sensor
bottom to TEST.
MANUAL MODE
ON-TIME
TEST 1 5 20
... back on.
AUTO
1 Second OFF
then...
Put the ON-TIME switch in the 1, 5 or
20 minute position.
Move ON-TIME Switch
to 1, 5 or 20 minutes
Mode Switching Summary
Flip light switch off
for one second then
back on*
MANUAL MODE
AUTO
TEST
Note: When first turned on wait about 1
2
minutes
for the circuitry to calibrate.
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.
* If you get confused while switching modes, turn
the power off for one minute, then back on. After
the calibration time the control will be in the
AUTO mode.
Mounting Bolt
Mounting Strap
Test
5 Sec
x
x
Auto
1, 5, 20 min.
x
Manual Until Dawn*
x
Mode: On-Time:
Works: Day
Night
Rubber Plug
Plastic Hanger
2 PAR Lamps
2 Wire
Connectors
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Page 2 INSTALLATION For easy installation, select an existing light with a wallswitch for replacement. W IRE THE L IGHT C ONTROL . ❒ Turn power off at the fuse or circuit breaker. ❒ Remove the existing light fixture. ❒ Install the mounting strap as shown using twoscrews that fit your junction box. ❒...
Page 3 Motion Motion TEST AND ADJUSTMENT ❒ Turn on the circuit breaker and light switch. NOTE: Sensor has a 1 2 minute warm up period before it will detect motion. When first turnedon or when switching modes wait 1 2 minutes. Bottom of Sensor Avoid aiming the sensor at: • Objects that change tempera...
Page 4 TROUBLESHOOTING GUIDE If you experience a problem with your Light Control, first follow this guide. You may also want to visitour Web site at: www.desatech.com. For additional assistance call 1-800-858-8501 8:00 am to 4:30PM Central Time, weekdays. POSSIBLE CAUSE SYMPTOM L i g h t s w i l lno...