Graco LTS 15 - Manual

Graco LTS 15

Graco LTS 15 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 4 – XR Model Sprayers; Disassembly; Installation Notes for page 5
  • Page 5 – Pressure Control Switch
  • Page 6 – R7 Model Sprayers; Check final assembly against Drive Train Detail.; Installation Notes for page 7
  • Page 7 – Pressure Control; Wiring Detail
  • Page 8 – Installation Notes for page 9
  • Page 10 – Disconnect pressure control harness from control; Assembly; X7 and LTS 17 Only: Install underside shroud
  • Page 12 – Graco Headquarters: Minneapolis
Loading the manual

309120K

Instructions

Pressure Control Switch
Replacement Kit

Use with M

AGNUM

dx, XR, 150 RPX, SR7 X5, X7, LTS 15, LTS 17,

ProX7, ProX9, Pro LTS 17 and Pro LTS 19 Model Sprayers

dx, XR, 150 RPX, (Series A) X5, and LTS 15 Pressure Control Switch Replacement Kit: 244266
2800 psi (19 MPa, 193 bar)

XR5 (Series B and C), XR7, XR9 (Series A and B) SR7, X7, LTS 17 (Series A and B), ProX7, ProX9 (Series A)
Pro LTS 17, and Pro LTS 19 Pressure Control Switch Replacement Kit: 244267
3000 psi (21 MPa, 207 bar)

dx, AX, XR9 European Models Pressure Control Switch Replacement Kit: 246286
3000 psi (21 MPa, 207 bar)

Pressure Relief Procedure

Important Safety Instructions
Read all warnings and instructions in this manual. Save these instructions.
For detailed sprayer information and warnings, see your Operation manual.

To help prevent injection injuries, follow this proce-
dure when you stop spraying and before you service
or clean the sprayer, remove parts, or repair leaks.

1.

Turn Power switch OFF. Unplug sprayer.

2.

Turn Spray/Prime valve to PRIME to relieve pressure. Turn Pressure
Control knob left (counterclockwise) to minimize pressure.

3.

Trigger gun.

4.

Put trigger safety in safety ON position.

NOTE: Leave Spray/Prime valve in PRIME
position until you are ready to spray again.

If you suspect that the spray tip or hose is completely clogged or that pressure
has not been fully relieved after following the steps above,
VERY SLOWLY
loosen the tip guard retaining nut or hose end coupling to relieve pressure
gradually. Then loosen it completely. Clear the tip or hose obstruction.

ti11868a

ENG

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Graco LTS 15

Summary

Page 4 - XR Model Sprayers; Disassembly; Installation Notes for page 5

XR Model Sprayers 4 309120K XR Model Sprayers Disassembly 1. Unplug electrical cord, and Relieve Pressure (see Pres-sure Relief Procedure on page 1). 2. Remove the cover screws (A) and front cover (B). 3. Remove yoke (C) and guide rods (D). 4. Disconnect pressure control wire harness (E) from contro...

Page 5 - Pressure Control Switch

XR Model Sprayers 309120K 5 XR Model Sprayers ti9701b Rod/Yoke Detail Drive Train Detail F S K R E L M G C D H J B A Pressure Control Switch Replacement Kit 244266 or 244267 Pressure Control Switch Replacement Kit 246286XR9 European Model

Page 6 - R7 Model Sprayers; Check final assembly against Drive Train Detail.; Installation Notes for page 7

SR7 Model Sprayers 6 309120K S R7 Model Sprayers Disassembly 1. Unplug electrical cord, and Relieve Pressure (see Pres-sure Relief Procedure on page 1). 2. Remove AutoPrime cover (A). 3. Remove the four cover screws (B) and front cover (C). 4. Remove yoke (D) and guide rods (E). 5. Disconnect pressu...

Other Graco Models

All Graco Other