2 Specifications WARNING FIRE AND SHOCK HAZARD • Always turn off power at the main power supply before installing, cleaning or removing the thermostat. Failure to do so could result in electrical shock hazard. • Do not use on voltages over 30 VAC. Higher voltages will damage the thermostat and could...
Page 4 - INSTALLATION INSTRUCTIONS
4 INSTALLATION INSTRUCTIONS PACKAGE CONTENTS/TOOLS REQUIRED: Package includes: • Thermostat base • Thermostat cover • Wiring labels • Screws • Wall anchors. Tools needed: 'ULOOZLWKƎELW • Hammer• Screwdriver• Putty WARNING ELECTRICAL SHOCK HAZARD — Turn off power by unplugging the unit or by removin...
Page 5 - TO REMOVE EXISTING THERMOSTAT
5 TO REMOVE EXISTING THERMOSTAT 1. Turn off power to heating and cooling system by removing the fuse or switching off the appropriate circuit breaker. 2. Remove cover of old thermostat. This should expose the wires. 3. Label the existing wires with the enclosed wire labels before removing wires. 4. ...
Page 6 - TO INSTALL THERMOSTAT; Thermostat installation
6 TO INSTALL THERMOSTAT IMPORTANT: Thermostat installation must conform to local and national building and electrical codes and ordinances. NOTE: Mount the thermostat about five feet above the floor. Do not mount the thermostat on an outside wall, in direct sunlight, behind a door or in an area affe...
Page 7 - NOTICE
7 TO INSTALL THERMOSTAT (cont.) 10. Seal hole for wires behind thermostat with non-flammable insulation or putty, or use a wall plate obtainable from a local hardware or home building store. 11. Use supplied screws to mount thermostat base to wall. 12. Insert stripped, labeled wires in matching wire...
Page 8 - WIRING DIAGRAMS; GH
8 WIRING DIAGRAMS Table 1: Terminals for six wires 1-stage heat/1-stage cool system B GH GH Y W C RR GL GL INDOOR F AN-L OW INDOOR F AN-HIGH COMPRESSOR 24 V AC COMMON 24 V AC HO T HEA T ELEC TRIC
Page 10 - CONFIGURATION MODE
10 CONFIGURATION MODE The configuration mode is used to set the RAK149F2 to match the PTAC’s heating/cooling system. The default setting of this thermostat is for 1-stage cooling with a 2-stage heat pump system. To configure for a 1-stage cooling with a 1-stage heating, see #2 in the Configuration M...
Page 12 - OPERATING FUNCTIONS; Off
12 OPERATING FUNCTIONS Off • In this mode, the thermostat will not turn on the heating or cooling devices (manual fan can operate). • Off is also used to access Configuration mode. Cool • In this mode, the thermostat controls the cooling system. • Press the < or > button to set the desired tem...
Page 13 - TESTING THE THERMOSTAT
13 Once the thermostat is installed, it should be thoroughly tested. NOTICE Do not use air conditioning beyond the simple test when the outdoor temperature is below 50 degrees. This can damage the air conditioning system. Note: Before testing the thermostat, move the Fan Auto/On switch to the Auto p...
Page 14 - Function
14 TESTING THE THERMOSTAT Heat Test1. Slide Function switch to Heat position. Heat mode screen is displayed. 2. Adjust set temperature so it is 5 degrees above room temperature. 3. Resistance heat should come on within a few seconds. 4. Adjust the set temperature so it is 2 degrees below the room te...
Page 15 - TROUBLESHOOTING TIPS; Problem
15 TROUBLESHOOTING TIPS Problem Solution No Display Check for 24 VAC; display is blank when 24 VAC is not present System fan does not come on properly Verify that wiring is correct. All thermostat but-tons are inoperative Verify that 24 VAC is present; unit will not operate when 24 VAC is not presen...
Page 16 - THERMOSTAT WARRANTY
16 THERMOSTAT WARRANTY For The Period Of: GE Appliances Will Replace: One Year Full Replacement of the thermostat which fails From the date of the due to a defect in materials or workmanship. original purchase For Warranty replacement, contact your distributor. What GE Appliances Will Not Cover: Ŷ S...
Page 17 - THERMOSTAT; NUMÉRIQUE
RENSEIGNEMENTS IMPORTANTS CONCERNANT LA SÉCURIT .............2 VUE D’ENSEMBLE .............................3 INSTALLATION ................................ 4 SCHÉMAS DE CÂBLAGE ...................8 CONFIGURATION MODE .................10 FONCTIONS D’UTILISATION ......... 12 ESSAI DU THERMOSTAT ..........
Page 18 - Fiche technique; AVERTISSEMENT
2 Fiche technique RENSEIGNEMENTS IMPORTANTS CONCERNANT LA SÉCURITÉ LISEZ TOUTES LES INSTRUCTIONS AVANT D’UTILISER CET APPAREIL AVERTISSEMENT RISQUE D’INCENDIE ET D’ÉLECTROCUTION Ŷ Mettez toujours l’alimentation électrique hors tension depuis la source d’alimentation électrique principale avant d’ins...
Page 20 - INSTRUCTIONS D’INSTALLATION; Contenu de l’emballage
4 INSTRUCTIONS D’INSTALLATION WARNING RISQUE D’ÉLECTROCUTION — Coupez l’alimentation en débranchant l’appareil ou en retirant le fusible ou mettant le disjoncteur approprié à la position OFF (hors tension) avant de retirer le thermostat. L’omission de procéder ainsi peut occasionner un choc électriq...
Page 21 - POUR RETIRER LE THERMOSTAT EXISTANT
5 INSTRUCTIONS D’INSTALLATION POUR RETIRER LE THERMOSTAT EXISTANT 1. Mettez le système de chauffage et de climatisation hors tension en retirant le fusible ou en déclenchant le disjoncteur approprié. 2. Retirez le couvercle du thermostat à changer. Ceci devrait exposer les fils. 3. Étiquetez les fil...
Page 23 - INSTALLATION DU THERMOSTAT
7 INSTALLATION DU THERMOSTAT (cont.) NOTICE Assurez-vous que la partie exposée des fils ne touche pas aux autres fils. 10 . Scellez le trou des fils derrière le thermostat à l’aide d’un isolant ou d’un mastic non inflammables, ou utilisez une plaque murale obtenue auprès d’une quincaillerie. 11. Tir...
Page 24 - SCHÉMAS DE CÂBLAGE
8 SCHÉMAS DE CÂBLAGE Tableau 1 : Bornes pour 6 fils - Système de chauffage à 1 étape/refroidissement à 1 étape B GH GH Y W C RR GL GL INDOOR F AN-L OW INDOOR F AN-HIGH COMPRESSOR 24 V AC COMMON 24 V AC HO T HEA T ELEC TRIC VENTILA T EUR INTÉRIEUR BAS VENTILA T EUR INTÉRIEUR HAUT COMPRESSEUR CHAUFF A...
Page 26 - MODE DE CONFIGURATION
10 MODE DE CONFIGURATION Le mode de configuration est utilisé pour régler le RAK148H2 pour qu’il corresponde au système de chauffage/refroidissement. Ce thermostat fonctionne avec des systèmes de pompe à chaleur jusqu’à 2 étages.Pour configurer le RAK148H2, procédez comme suit: REMARQUE : La fonctio...
Page 28 - FONCTIONS D’UTILISATION; OFF
12 FONCTIONS D’UTILISATION OFF (arrêt) • Dans ce mode, le thermostat n’allumera pas les dispositifs de chauffage ou de refroidissement (le ventilateur manuel peut fonctionner). • Le mode OFF sert aussi à accéder aux mode Configuration . Cool (refroidissement) • Dans ce mode, le thermostat contrôle l...
Page 29 - CAUTION; ESSAI DU THERMOSTAT
13 Une fois le thermostat installé, il doit faire l’objet d’un test rigoureux. CAUTION N’utilisez pas le climatiseur/ thermopompe lorsque la température extérieure descend sous 50°F. Vous pourriez endommager le climatiseur. Remarque : Avant de tester le thermostat, mettez le commutateur Fan Auto/On ...
Page 30 - Test du chauffage
14 ESSAI DU THERMOSTAT Test du chauffage 1. Glissez le commutateur des fonctions à la position Heat. La fenêtre du mode Heat s’affiche. 2. Réglez la valeur de consigne de la température de manière à ce qu’elle se situe à cinq (5) degrés au-dessus de la température de la pièce. 3. La chaleur de résis...
Page 31 - CONSEILS DE DÉPANNAGE
15 CONSEILS DE DÉPANNAGE Problème Solution $XFXQDႈFKDJH Assurez-vous que la tension est de 9$&O¶DႈFKHXUQHIRQFWLRQQHUD pas sans cette tension. Le système de ventilation ne se met pas en marche correctement 9pUL¿H]OHERQpWDWGXFkEODJH Aucun bouton du thermostat ne fonctionne. Assurez-vous que la ten...
Page 32 - GARANTIE LIMITÉE DU THERMOSTAT
16 GARANTIE LIMITÉE DU THERMOSTAT Ce que GE Appliances ne couvre pas : Ŷ Frais de déplacement pour réparation vers votre emplacement. Ŷ Une installation mal effectuée. Si vous avez un problème d’installation, communiquez avec votre installateur. Vous êtes responsable d’effectuer correctement les rac...