CNH2 (EXTERNAL SWITCH
SETTING)
Device Driver
You need to install Fujitsu's device driver to avoid the 2KB sector
problem in Windows9x and the OS-timeout-problem in Windows9x and
NT3.51/4.0.
MCE3064SS/MCF3064SS/MCE3130SS HANDLING AND MAINTENANCE
WORLD WIDE WEB SITE
Corporate http://www.fujitsu.co.jp/
SINGAPORE http://www.fujitsu-computers.com.sg/
USA
http://www.fcpa.com/
CANADA
http://www.fujitsu.ca/
EUROPE http://www.fujitsu-europe.com/
AUSTRALIA http://www.fujitsu.com.au/
Orientation
The drive can be installed in one
of three orientations; either PCA
up or on either side edge.
Ejecting cartridge
C a r t r i d g e s c a n b e e j e c t e d b y
pressing the eject key or by a
S C S I e j e c t c o m m a n d . N e v e r
eject a cartridge mechanically
except in an emergency.
C l e a n i n g l e n s a n d m e d i a
recommendation
Clean the lens on the drive head
and the disk media once every
t h r e e m o n t h s . M o r e f r e q u e n t
cleaning may be required in a
d i r t y e n v i r o n m e n t . U s e t h e
F u j i t s u h e a d c l e a n i n g k i t a n d
m e d i a c l e a n i n g k i t . H e a d
cleaning kits from other vendors
will not work.
1
2
3
4
6
5
7
8
9
10
11
12
13
14
15
16
0V
TTL-IC
OPERATOR PANEL
Note: The cable length must not exceed 30cm.
This guide is prepared to instruct the user on the switch and jumper
settings in the MCE3064SS/MCF3064SS/MCE3130SS when you install
your MCE3064SS/MCF3064SS/MCE3130SS.
Note; Factory default settings are marked with
✻
.
Layout of PCA
SCSI ID Setting
SW1 AND CNH2 SETTINGS
Switch 1 sets the SCSI ID and some drive functions and CNH2 sets
additional drive functions.
SW1
CNH1 (TERMINATING POWER AND SCSI TERMINATION)
Terminal CNH1 uses shorting bars to set the power source and to
enable or disable SCSI termination.
Key#
Function
Key on
Key off
01
✻
02
SCSI ID (see table 1 above)
————
————
✻
03
✻
04
SCSI data bus parity check
Enabled
✻
Disabled
05
Write cache mode
Enabled
Disabled
✻
06
Device type mode
MO
✻
Fixed Disk
07
Spindle automatic stop mode
Enabled
Disabled
✻
08
Factory test (Not to be set by user)
Enabled
Disabled
✻
SCSI ID
SW1-01 SW1-02 SW1-03
0
✻
Off
Off
Off
1
Off
Off
On
2
Off
On
Off
3
Off
On
On
4
On
Off
Off
5
On
Off
On
6
On
On
Off
7
On
On
On
Table 1
MCE3064SS, MCF3064SS,
MCE3130SS
Magneto-Optical Disk Drives
Installation Guide
Installationsanleitung
Guide d'installation
COPYRIGHT FUJITSU LIMITED
SEPT. 1999
C156-E117-02XA
Pin#
Function
Open
Short
1
Cartridge-in detection
—
—
2
SCSI ID 4
—
—
3
LED source (+5 V)
—
—
4
SCSI ID2
—
—
5
LED source (–)
—
—
6
SCSI ID1
—
—
7
Signal to eject cartridge
—
—
8
Ground
—
—
9
Device type mode
Fixed disk
MO
10
SCAM mode
Disabled
Enabled
11
Write verify mode
Enabled
Disabled
12
Ground
—
—
13
Macintosh mode
Disabled
Enabled
14
SCSI type 0
SCSI 2
SCSI 1
15
Terminating resister mode
Disabled
Enabled
16
Ground
—
—
Pin# Function
Short
Open
1–2
Power supplied by Supplied Not
drive
supplied
3–4
Power supplied by Supplied Not
host controller
supplied
5–6
SCSI termination
Enabled
Disabled
enabled
Power supplied by
1–2
3–4
Drive
Short Open
Host controller
Open Short
Drive and Host
Short Short