Fluke T6-600/62MAX+/1AC - User Manual
Fluke T6-600/62MAX+/1AC Multimeter – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
HO
LD
3
2
1
5
7
6
200
A
CA
T
10
00
V
CA
T
60
0
V
4
HOLD
200
A
CA
T
10
00
V
CA
T
60
0
V
AUTO
SELECT
T6-1000
ELECTRICAL TESTER
5
2
7
3
1
4
6
True
RMS
Test Lead Assembly (T5-RLS) Replace
only with Fluke double-insulated leads (
) PN 4462973
TP1 Single Probe, Flat-Tip, Red
PN 648128
TP1 Single Probe, Flat-Tip, Black
PN 648102
TP38 Single Probe, Round-Tip, Red
PN 1276841
TP38 Single Probe, Round-Tip, Black
PN 1276852
Battery Door
PN 4944370
Battery Door Screw
PN 1618578
Use only specified replacement parts
Quick Reference Guide
Model T6-1000 Model T6-600
Function
Requires
Test Leads
Range
Range
Resolution
Accuracy
[1]
FieldSense
Voltage ac true-rms
No
1000 V
600 V
1 V
±(3 % + 3 counts)
45 Hz to 66 Hz
[2] [3]
FieldSense
Current ac true-rms
No
200.0 A
200.0 A
0.1 A
±(3 % + 3 counts)
45 Hz to 66 Hz
FieldSense
frequency (Hz)
No
45 Hz to 66 Hz
1 Hz
±(1 % + 2 counts)
[3]
Voltage ac true-rms
Yes
1000 V
600 V
1 V
±(1.5 % + 2 counts)
45 Hz to 66 Hz
Voltage dc
Yes
1000 V
600 V
1 V
±(1 % + 2 counts)
Resistance
Yes
2000 Ω
2000 Ω
1 Ω
±(1 % + 2 counts)
Yes
20.00 kΩ
0.01 kΩ
Yes
100.0 kΩ
0.1 kΩ
[1] Accuracy: ±( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at
18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are accoupled, RMS responding.
[2] Add 3 % typical without an external ground connection. External ground connection required for user wearing insulated
gloves, standing on an insulated ladder, or otherwise insulated from earth ground.
[3] FieldSense is specified from 16 V to 100 % of range.
Fork opening
17.8 mm
Temperature
Operating
Storage
-10 °C to +50 °C (+14 °F to +122 °F)
-30 °C to +60 °C (-22 °F to +140 °F)
Altitude
Operating
Storage
2000 m
10 000 m
Relative Humidity
0 % to 90 %, 5 °C to 30 °C (41 °F to 86 °F)
0 % to 75 %, 30°C to 40 °C (86 °F to 104 °F)
0 % to 45 %, 40°C to 50 °C (104 °F to 122 °F)
Battery Type and Life
2x AA (IEC LR6) 360 hr continuous, typical is 200 hr using the FieldSense function
Temperature coefficient
0.1 x (specified accuracy) / °C for <18°C or >28 °C (<64.4 °F or >82.4 °F)
T6-600/T6-1000
Electrical Tester
with FieldSense Technology
»
See
Safety Information.
Go to www.fluke.com to register your product and find more information, or
download this Quick Reference Guide in other languages.
PN 4897598 September 2017 Rev. 4, 7/18
© 2017-2018 Fluke Corporation. All rights reserved.
Specifications are subject to change without notification.
Fork Opening 17.8 mm
Overview
Wire Position
1 Wire Only
Finger Guard
For safe operation, hold the
Tester behind the finger guard.
Display
Model T6-1000
Model T6-600
X
Hazardous Voltage ≥30 V
Function Selection/On/Off
Auto Off
15 min
FieldSense Ground Contact
Test Probes/Storage Dock
Symbols
W
WARNING. RISK OF DANGER.
Test with fork and FieldSense ground contact.
»
Consult user documentation.
Test with fork and ground probe.
Y
Hazardous voltage ≥30 V.
Test with probes.
Battery full charge.
FieldSense Measurement: Fluke voltage/current
sensing technique.
Battery low. Replace.
J
Good earth ground connection.
Back light
J
No earth ground connection.
Specifications
USA: 1-800-44-FLUKE (1-800-443-5853)
Canada: 1-800-36-FLUKE (1-800-363-5853)
Europe: +31 402-675-200
Japan: +81-3-6714-3114
Singapore: +65-6799-5566-5655
China: +86-400-921-08365
Anywhere in the world: +1-425-446-5500
● HT6 Belt Holster
● TPAK Hanger
● PRV240FS Proving Unit
● AC285 SureGrip™ Alligator Clips
● AC220 SureGrip™ Alligator Clips
● C60 softcase
Contact Fluke
USA:
.
Lead Replacement
Accessories
● HT6 ●
Replacement Parts
Wire must contact
the bottom of the
fork opening.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.