Page 2 - The contents of this manual are subject to change without notice.
i i FCC Notice Federal Communications Commission (FCC) Radio Frequency Interference Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions; (1) This device may not cause harmful interference, and (2) this device must accept any interference...
Page 3 - Contents
ii ii Contents 1. Features.................................................................................................. 1 2. General Specification .............................................................................. 1 3. Unpacking and Checking the Parts ..................................
Page 5 - (7) Reverse characters can be specified using the Epson command set.; General Specification; NO ITEM
1 1 1. Features (1) Data can be display on 20 columns x 2 lines. (2) Blue–green color and large character are easy to see. (3) The DIP switches setting emulate commands mode, baud rate and international character. (4) Command emulation modes include: POS7300, EPSON ESC/POS, ADM787/ ADM788, DSP800, A...
Page 6 - Unpacking and Checking the Parts
2 2 3. Unpacking and Checking the Parts G 501 m m 191 m m 225 mm 93 mm 281 m m Pole Display Module Flat Cable (DB-9P to DB-9P flat cable connector) Base Unit Two pieces of pole support (1x22cm, 1x9cm) Installation guide Power Adapter 4. Interface 4.1. Specifications Data transmission: Serial Synchro...
Page 7 - Figure of VFD Pole Display Base; PWR: Power input connector from adapter; RJ45: Connect to display panel
3 3 4.2. Interface 4.2.1. Stand alone VFD Pole Display base Below illustrate the configuration of Stand alone VFD Pole Display base. Figure of VFD Pole Display Base 4.2.2. Interface connector PWR COM RJ45 PWR: Power input connector from adapter Connector type: DC jack (5.5/2.1) Pin assignment: N...
Page 8 - Dip Switch and Software Setting; Euro Dollar Symbol on Char D5h.
4 4 5. Dip Switch and Software Setting 5.1. Command type selection SW1 SW2 SW3 Command type Demo mode support Default ON ON ON POS7300 No * OFF ON ON EPSON ESC/POS Yes ON OFF ON ADM 787/ ADM 788 No OFF OFF ON DSP800 Yes ON ON OFF AEDEX/ EMAX No OFF ON OFF UTC/P No ON OFF OFF UTC/S No OFF OFF OFF CD5...
Page 10 - AEDEX
6 6 5.7.4. Command type setting command STX 05 C n ETX /Change the command type setting/ ASCII Format STX 05 C n ETX Dec. Format [02][05][67] n [03] Hex. Format [02h][05h][43h] n [03h] 30h ≦ n ≦ 37h Description This command will change the command type and initialize the display. The display emulati...
Page 11 - Command List Table; Command List Table – 1
7 7 6. Command List Table Command List Table – 1 EPSON POS7300 CD5220 D101 UTC/S UTC/P AEDEX ADM788 DSP800 Move cursor right O O O Move cursor left O O O Move cursor up O O O Move cursor down O O O Move cursor to right-most position O O O Move cursor to left-most position O O O Move cursor to home p...
Page 12 - Command List Table – 2
8 8 Command List Table – 2 EPSON POS7300 CD5220 D101 UTC/S UTC/P AEDEX ADM788 DSP800 Upper line message scroll once pass O O Change attention code O O Two line display O O Clear upper line and move cursor to upper left-end position O Clear bottom line and move cursor to bottom left-end position O Se...
Page 15 - The parameter of international fonts set control by command “; ESC f n; The parameter of the code table control by command “; ESC c n
11 11 Note: 3. The parameter of international fonts set control by command “ ESC f n ” Parameter “n” International Font Set ‘A’ U.S.A. ‘G’ Germany ’I’ Italy ‘J’ Japan ‘U’ U.K. ‘F’ France ‘S’ Spain ‘N’ Norway ‘W’ Sweden ‘D’ Denmark I ‘E’ Denmark II ‘L’ Slavonic ‘R’ Russia 4. The parameter of the code...
Page 17 - International font set
13 13 7.8. EPSON ESC/POS command list Command Code (hex) Function description ESC t n 1B 74 n (n=00-0fh) Select character code table. See Table 7-2. ESC R n 1B 52 n (n=00-0fh) Select international character set. See Table 7-1. US r n 1F 72 n (n=00,01) Select/cancel reverse character. US MD1 1F 01 Sp...
Page 21 - Эį
17 17 8.8. Page 5 (PC865: Nordic) (80H – FFH) 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 80H Ç ü é â ä à å ç ê ë è ï î ì Ä Å 90H É æ Æ ô ö ò û ù ÿ Ö Ü ø £ Ø Pt ƒ A0H á í ó ú ñ Ñ a o ¿ ⌐ ¬ ½ ¼ ¡ « ¤ B0H ░ ▒ ▓ │ ┤ ╡ ╢ ╖ ╕ ╣ ║ ╗ ╝ ╜ ╛ ┐ C0H └ ┴ ┬ ├ ─ ┼ ╞ ╟ ╚ ╔ ╩ ╦ ╠ ═ ╬ ╧ D0H ╨ ╤ ╥ ╙ ╘ ╒ ╓ ╫ ╪ ┘ └...
Page 23 - Set the string display mode, and write string to display; Set the string display mode, write to upper or lower line d1 d2 d3 ... dn {1; Upper line message scroll continuously; The cursor will remain stationary.; The cursor will remain stationary.
19 19 9. Command details 9.1. Overwrite mode In this mode, the cursor will move rightward and begin from the upper left-end position. When the cursor reached the end of the upper line, the cursor will move down to the bottom left-end position to continue. When the cursor reached the end of the botto...
Page 25 - Control code set
21 21 10. Control code set HEX CODE HEX CODE 00H NULL 10H DLE 01H SOH, MD1 11H DC1 02H STX, MD2 12H DC2 03H ETX, MD3 13H DC3 04H EOT, MD4 14H DC4 05H ENQ, MD5 15H NAK 06H ACK, MD6 16H SYN 07H BEL, MD7 17H ETB 08H BS, MD8 18H CAN 09H HT 19H EM 0AH LF 1AH SUB 0BH VT, HOM 1BH ESC 0CH FF, CLR 1CH FS 0DH...
Page 26 - Appendix A: Display Module Dimension
22 22 Appendix A: Display Module Dimension 70mm 39mm 0.38o 200mm 176mm 158.6mm 9.0mm 0.25mm 5.25mm 0.85mm 0.25mm 1.5mm 1.05mm 1.5mm 1.5mm 22.5mm 9.5mm 6.65mm