Daikin WHA- User Manual

Daikin WHA

Daikin WHA– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
Page: / 48

Table of Contents:

  • Page 3 – Product Identifier
  • Page 4 – Safe Operation Rules; To prevent electrical shock, disconnect electric power to; CAUTION; WARNING; Do Not Vent; Clean Air Act requires the recovery of any residual re
  • Page 5 – Table 1: Electrical data; Breaker; FLA = Full Load Amps
  • Page 6 – Table 2: Capacity data; Mounting the Unit; Note: It is important that both water lines be insulated. For run
  • Page 7 – on page; Water piping exposed to outside may freeze.; Well Water Application Open Loop
  • Page 8 – Start Up; Maintenance Procedures; Notes: DO NOT place refrigeration gauges on system for
  • Page 9 – Dimensions - Size 036
  • Page 10 – Dimensions - Size 180
  • Page 12 – Physical Data; Cooling Mode; Table 4: Models WRA and WCA; Heating Mode; Table 5: Models WRA and WHA
  • Page 13 – Antifreeze Correction; perrformance reductions.; Waterflow Correction
  • Page 14 – Note: See wiring diagram legend on
  • Page 15 – Legend
  • Page 16 – Note: Always disconnect power to WW* unit before moving; Figure 2: Thermistor temperature vs. resistance graph; Thermistor Temperature Vs. Resistance
  • Page 17 – Note: The 60 psig low pressure switch is jumpered out in low; Operation Of The HPS Terminals
  • Page 18 – Figure 3: Compressor control module functional operation; Disconnect power to
  • Page 21 – Figure 5: Thermistor temperature vs. resistance graph
  • Page 23 – Figure 6: Compressor control module functional operation
  • Page 24 – Note: See continuation of wiring diagram on
  • Page 25 – Continuation of wiring diagram from
  • Page 27 – Figure 8: Thermistor temperature vs. resistance graph
  • Page 29 – Figure 9: Compressor control module functional operation
  • Page 31 – Note: Continuation of wiring diagram from
  • Page 33 – Figure 11: Thermistor temperature vs. resistance graph
  • Page 35 – Figure 12: Compressor control module functional operation
  • Page 39 – Figure 14: Thermistor temperature vs. resistance graph
  • Page 41 – Figure 15: Compressor control module functional operation
  • Page 42 – Model WHA
  • Page 43 – Model WRA; Reverse Cycle, No Domestic Hot Water
  • Page 44 – Model WCA
  • Page 45 – General Information; Unit Function
  • Page 46 – Symptom
Loading the manual

IM 1072-3

Group:

WSHP

Part Number:

910163742

Date:

February 2015

Daikin Water to Water Source Heat Pumps

3 to 35 Tons with R-410A

WRA - Heating and Cooling Models
WHA - Heating Only Models
WCA - Cooling Only Models

Installation and Maintenance Manual

People and ideas you can trust.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - Product Identifier

P roduCt n omenClature Category Code Item Code Option Code Designation & Description Product Category 1 1 W = Water Source Heat Pump Product Identifier 2 2-4 WCA = Base Cooling Only Unit with Copper Coaxial Water Coils WHA = Base Heating Only Unit with Copper Coaxial Water Coils WRA = Base Cooli...

Page 4 - Safe Operation Rules; To prevent electrical shock, disconnect electric power to; CAUTION; WARNING; Do Not Vent; Clean Air Act requires the recovery of any residual re

s afety I nformatIon Safe Operation Rules Installation and maintenance are to be performed only by qualified personnel who are familiar with and in com - pliance with state, local and national codes and regula - tions, and experienced with this type of equipment.Please take a few minutes to read the...

Page 5 - Table 1: Electrical data; Breaker; FLA = Full Load Amps

e leCtrICal d ata WRA, WHA, WCA 036 – 420 Table 1: Electrical data Unit Size Voltage/Hz/Ph Compressor Total Unit FLA Voltage Min ./Max . Minimum Circuit Ampacity Max . Circuit Breaker Maximum Fuse HACR Breaker Quantity RLA (each) LRA (each) 036 208-230/60/1 1 16.7 79 .0 33 .4 197/253 20 .9 35 35 208...