Page 3 - TABLE OF CONTENTS
• VRV Systems • RXYSQ-P8V1 1 • Outdoor Unit • RXYSQ-P8V1 TABLE OF CONTENTS RXYSQ-P8V1 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 4 - Features
• Outdoor Unit • RXYSQ-P8V1 1 • VRV Systems • RXYSQ-P8V1 2 1 Features Ou td oo r Un i VR V Sy st em s RX YS Q- P8 V1 VR VI II -S h e Inverter
Page 5 - Specifications; -1 Technical Specifications
3 2 • VRV Systems • RXYSQ-P8V1 3 • Outdoor Unit • RXYSQ-P8V1 2 Specifications 2-1 Technical Specifications RXYSQ4P8V1 RXYSQ5P8V1 RXYSQ6P8V1 Capacity range HP 4 5 6 Cooling capacity Nom. kW 12.6 14.0 15.5 Heating capacity Nom. kW 14.2 16.0 18.0 Power input - 50Hz Cooling Nom. kW 3.24 (1) 3.51 (1) 4.5...
Page 6 - -2 Electrical Specifications
• Outdoor Unit • RXYSQ-P8V1 2 • VRV Systems • RXYSQ-P8V1 4 2 Specifications Standard Accessories : Installation manual; Quantity : 1;Standard Accessories : Operation manual; Quantity : 1;Standard Accessories : Connection pipes; Quantity : 3; Fan motor 2 Model Brushless DC motor Speed Cooling Nom. rp...
Page 8 - Options
• Outdoor Unit • RXYSQ-P8V1 3 • VRV Systems • RXYSQ-P8V1 6 3 Options 3 - 1 Options RXYSQ-P8V1 4TW33621-3 NOTES Note: All options are kits. No Item RXYSQ4 RXYSQ5 RXYSQ6 1 Cool / Heat selector KRC19-26A6 2 Fixing box KJB111A 3 Refnet header KHRQ22M29H 4 Refnet joint KHRQ22M20TA 5 Central drain plug KK...
Page 9 - Capacity tables; - 1 Capacity Table Legend
3 4 • VRV Systems • RXYSQ-P8V1 7 • Outdoor Unit • RXYSQ-P8V1 4 Capacity tables 4 - 1 Capacity Table Legend ,QRUGHUWRIXO¿OOPRUH\RXUUHTXLUHPHQWVRQTXLFNDFFHVVRIGDWDLQWKHIRUPDW\RXUHTXLUHZHKDYHGHYHORSHGDWRROWRFRQVXOWFDSDFLW\WDEOHV %HORZ\RXFDQ¿QGWKHOLQNWRWKHFDSDFLW\WDEOHGDWDEDVHDQGDQRYHUYLHZRIDOOWKHWRROVZ...
Page 10 - - 2 Integrated Heating Capacity Correction Factor
• Outdoor Unit • RXYSQ-P8V1 4 • VRV Systems • RXYSQ-P8V1 8 4 Capacity tables 4 - 2 Integrated Heating Capacity Correction Factor 3TW30402 NOTES 1. The gure shows that the integrated heating capacity expresses the integrated capacity for a single cycle (from defrost operation to defrost operation) in...
Page 11 - - 3 Capacity Correction Factor
3 4 • VRV Systems • RXYSQ-P8V1 9 • Outdoor Unit • RXYSQ-P8V1 4 Capacity tables 4 - 3 Capacity Correction Factor
Page 14 - Dimensional drawings; - 1 Dimensional Drawings
• Outdoor Unit • RXYSQ-P8V1 5 • VRV Systems • RXYSQ-P8V1 12 5 Dimensional drawings 5 - 1 Dimensional Drawings RXYSQ-P8V1 Hole for anchorbolt 4-M12 1 Gas pipe connection A 2 Liquid connection pipe Ø9.5 are 3 Service port (in the unit) (2x) 4 Electronic connection and grounding terminal M5 (in switch ...
Page 15 - Centre of gravity; - 1 Centre of Gravity
3 6 • VRV Systems • RXYSQ-P8V1 13 • Outdoor Unit • RXYSQ-P8V1 6 Centre of gravity 6 - 1 Centre of Gravity 4D052604B
Page 16 - Piping diagrams; - 1 Piping Diagrams
• Outdoor Unit • RXYSQ-P8V1 7 • VRV Systems • RXYSQ-P8V1 14 7 Piping diagrams 7 - 1 Piping Diagrams RXYSQ-P8V1 3D052712 Electronic expansion valve Electronic expansion valve Heat exchanger Service port Service port Filter Filter Filter Compressor ACCUMULATOR Stop valve (With service port on eld pipi...
Page 17 - Wiring diagrams
3 8 • VRV Systems • RXYSQ-P8V1 15 • Outdoor Unit • RXYSQ-P8V1 8 Wiring diagrams 8 - 1 Wiring Diagrams - Single Phase RXYSQ-P8V1 Cool/heat selector K1M Magnetic contactor (M1C) R6T Thermistor (subcooling H.Ex) S1S Selector switch (fan/cool-heat) K1R Magnetic relay (Y1S) R7T Thermistor (liquid pipe 1)...
Page 18 - External connection diagrams; - 1 External Connection Diagrams
• Outdoor Unit • RXYSQ-P8V1 9 • VRV Systems • RXYSQ-P8V1 16 9 External connection diagrams 9 - 1 External Connection Diagrams RXYSQ-P8V1 3TW33626-1 NOTES 1. All wiring, components and materials to be procured on the site must comply with the applicable local and national codes.2. Use copper conducto...
Page 19 - Sound data; 0 - 1 Sound Power Spectrum
3 10 • VRV Systems • RXYSQ-P8V1 17 • Outdoor Unit • RXYSQ-P8V1 10 Sound data 10 - 1 Sound Power Spectrum RXYSQ4P8V1 3TW27637-3 NOTES 1 dBA = A-weighted sound power level. (A-scale according to IEC) 2 Reference acoustic intensity 0dB = 10E-6 ȝ W/m 2 3 Measured according to ISO 3744 Sound power level ...
Page 22 - Installation; 1 - 1 Installation Method
• Outdoor Unit • RXYSQ-P8V1 11 • VRV Systems • RXYSQ-P8V1 20 11 Installation 11 - 1 Installation Method 5;<6439 '' 2EVWDFOHRQERWKVLGHV RUPRUH RUPRUH RUPRUH RUPRUH RUPRUH RUPRUH RUPRUH RUOHVV RUPRUH RUPRUH RUPRUH RUOHVV RUPRUH RUPRUH RUPRUH RUOHVV RUPRUH RUPRUH RUPRUH RUPRUH RUPRUH RUPRUH RUPRUH ...
Page 23 - 1 - 2 Refrigerant Pipe Selection
3 11 • VRV Systems • RXYSQ-P8V1 21 • Outdoor Unit • RXYSQ-P8V1 11 Installation 11 - 2 Refrigerant Pipe Selection 4PW68122-1_1
Page 24 - Operation range; 2 - 1 Operation Range
• Outdoor Unit • RXYSQ-P8V1 12 • VRV Systems • RXYSQ-P8V1 22 12 Operation range 12 - 1 Operation Range 3D045713F
Page 25 - BARCODE
EE DE N1 4-1 0 0 • 0 3/1 4 • Co pyr igh t D aiki n Th e p re sen t p u bl ic at io n supe rs ed es E E D E N 1 3- 10 0 The present leaflet is drawn up by way of information only and does notconstitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V.has compiled the content of this leafle...