Page 2 - With passion and precision, Daikin is redefining how the; The Daikin Difference
Daikin Split Systems are a perfect fit for residential applications and are also used extensively in schools, universities, hospitals, nursing homes, hotels, office buildings, data rooms or churches and a multitude of other light commercial applications. n Performance worldwide. Daikin has sold mill...
Page 3 - A Powerful Product Portfolio; Quaternity; Other Product Lines Available
A Powerful Product Portfolio Single Split - Pages 12 - 17 SEER 18 Heat Pump FTXS/RXSCool Only FTKS/RKS 16 Heat Pump FTXS/RXS 13 Concealed FDXS/RXS 13 Heat Pump FTXN/RXNCool Only FTKN/RKN Capacity 9kBtu/h 12kBtu/h 15kBtu/h 18kBtu/h 24kBtu/h 450 sq. ft. 625 sq. ft. 813 sq. ft. 1,050 sq. ft. 1,460 sq. ...
Page 4 - Intelligent to the Core; Advantages of the inverter technology; The Smart Choice
FTXG FTXS/CTXS FDXS FCQ FHQ FAQ Overcooling Poor temperature control Inefficient use of energy Minimal temperature fluctuationEfficient use of energy Non-inverter AC Daikin Inverter AC Intelligent to the Core The Comfort of Choice A wide range of indoor units allows for flexible installation. There ...
Page 5 - Sound Efficient; Swing Compressor; Ultimate Comfort For The Home; Energy Efficient; Reluctance Digitally Commutated (DC) Motor
Sound Efficient Swing Compressor The design of the swing compressor reduces friction during operation for smoother and quieter rotation with less vibration resulting in a more durable compressor. It also minimizes the leakage of refrigerant gas during compression. The result is a system that operate...
Page 6 - Daikin Compatibility Matrix
Single Split Wall Mounted Indoor Units Concealed Indoor Units FTKN09JEVJU FTKN12JEVJU FTXN09JEVJU FTXN12JEVJU FTXS09HVJU FTXS12HVJU FTXS15HVJU FTXS18HVJU FTXS24HVJU FTKS09JEVJU FTKS12JEVJU FTXS09JEVJU FTXS12JEVJU FDXS09DVJU FDXS12DVJU Outdoor Units SEER 13 Cool Only RKN09JEVJU RKN12JEVJU Heat Pu...
Page 7 - provides a personal tax credit to
TAX CREDIT QUALIFIED Daikin sells products that may be eligible for the tax credit opportunities made available under The American Recovery and Reinvestment Act of 2009. The American Recovery and Reinvestment Act of 2009 provides a personal tax credit to homeowners for the 2009 and 2010 tax years fo...
Page 8 - Features Checklist
Features Checklist Single Split Multi Split SkyAir Energy Efficiency SEER 13 SEER 16 SEER 18 SEER 22 Type Cool Only Heat Pump Heat Pump Heat Pump Heat Pump Heat Pump Heat Pump Cool Only Heat Pump Heat Pump Heat Pump Heat Pump Heat Pump Heat Pump Heat Pump Heat Pump Heat Pump Heat Pump Heat Pump Mode...
Page 9 - Key Features & Benefits; Superior Comfort Control
Key Features & Benefits Superior Comfort Control Indoor Unit Quiet Operation. Sound levels are reduced by 2-3 decibels (dB) from the low fan speed for quieter and gentler heating and cooling. Outdoor Unit Quiet Operation. Outdoor unit sound levels can be reduced by 3dB for times when quieter ope...
Page 10 - Timers
Worry Free Auto-Restart. The unit memorizes the operation mode, airflow and temperature settings. Should there be a power failure when the unit is in operation, it will automatically return to the same operating conditions when the power is restored. Self-Diagnosis. In the event that a problem devel...
Page 11 - Home Leave Operation; Remote Controllers; Wireless Remote Controller ARC452A9; Wireless Remote
With the FTXS/CTXS systems, you have the ability to record a favorite set temperature and air flow rate. The best part is retrieving them by a simple push of the HOME LEAVE button on the remote controller. Another great advantage of this feature is its energy-savings mode. When sleeping or out of th...
Page 12 - Simple Installation; Single Split Systems; The Luxury of Choice.
At Daikin, we’re not just concerned with how comfortable our systems make you feel — but how comfortable you feel about our systems. Instead of large condensing units with noisy compressors and large duct work, Daikin systems are comprised of small, easily located outdoor units and a connected pair ...
Page 13 - Standard Efficiency - SEER 13
Control box ) s e rt n e c e l o h -t l o b t o o F ( 6“ 1/ 3 1 2 2 el o h -tl o b t o o F( )s ers t n e c 3“ 1 12” or more In sites with poor drainage use block bases for outdoor units Floor connector Insulate both lines separately 9.8” from wall ARC FDXS Controllers (Options) Central Remote Contro...
Page 14 - Wall Mounted Indoor Units; Cooling Only
I N V E RT E R R - 4 1 0 A Wall Mounted Indoor Units Indoor Units - FTXN_JEVJU Model FTXN09JEVJU FTXN12JEVJU Refrigerant R-410A R-410A Front Panel Color Off-White Off-White Cooling Capacity ( min./nom./max.) Btu/h 4,400/8,500/9,500 4,400/10,500/12,000 Sensible Cooling Capacity Btu/h 5,270 6,460 Heat...
Page 15 - Indoor Units - FTXS_HVJU Wall Mounted Units
ARC Standard Efficiency - SEER 13 Heat Pump Controllers (Options) Central Remote Controller DCS302C71 Unified On/Off Controller DCS301C71 Schedule Timer DST301BA61 Interface Adaptor for DIII-NET use KRP928B2S Wired Remote Controller BRC944B2_A08 Indoor Units - FTXS_HVJU Wall Mounted Units Model FTXS...
Page 17 - Cool; High Efficiency - SEER 18
Indoor Units - FTKS_JEVJU Model FTKS09JEVJU FTKS12JEVJU Refrigerant R-410A R-410A Front Panel Color Off-White Off-White Cooling Capacity ( min./nom./max.) Btu/h 4,400/8,500/9,500 4,800/10,500/11,500 Sensible Cooling Capacity Btu/h 5,320 6,520 Airflow-Wet (H/M/L/SL) cfm 325/261/187/141 328/272/198/15...
Page 19 - DEHUMIDIFICATION; without lowering the temperature
Quaternity Indoor Units - FTXG_HVJU Wall Mounted Units. For use with RXG_HVJU Models Model FTXG09HVJU FTXG12HVJU FTXG15HVJU Cooling Capacity (min. - nom. - max.) Btu/h 5,300 - 9,000 - 12,300 5,300 - 12,000 - 15,700 5,300 - 15,000 - 18,000 Heating Capacity (min. - nom. - max.) Btu/h 4,400 - 12,000 - ...
Page 20 - Purifies and removes allergens from the air; Flash Streamer
The MS2 coliphage was used to simulate a virus; this is an extensively studied method and is used as an indictor of a virus survival. It was released into the space and the Flash Streamer was activated. This was then compared to the same concentration of MS2 and the decomposition with natural ventil...
Page 21 - Advanced functions; Best
Comfortable mode In heating mode, the warm air is directed straight downward to your feet. In cooling mode, the cool air descends from the ceiling gradually throughout the entire room. The comfortable mode prevents air from blowing directly on the skin, which provides a gentle and comfortable enviro...
Page 22 - Flexible Product Range
FTXS/CTXS FDXS 2MXS 3MXS/4MXS Multi-Split Systems A Daikin Multi-Split System can serve from two to four rooms using only one outdoor unit, and allows individual control of the air conditioning in each room. On top of the savings generated from the flexibility of Daikin’s Multi-Split systems, furthe...
Page 23 - zones, 3 zones or 4 zones; Indoor Units - Wall Mounted Units; Outdoor Units
2 zones, 3 zones or 4 zones Controllers (Options) Central Remote Controller DCS302C71 Unified On/Off Controller DCS301C71 Schedule Timer DST301BA61 Interface Adaptor for DIII-NET use KRP928B2S Wired Remote Controller BRC944B2_A08 Indoor Units - Slim Duct Built-In Units Model FDXS09DVJU FDXS12DVJU Re...
Page 24 - Performance
Certified Efficiency Performance Values System AHRI Number Combined With Nominal cooling capacity EER SEER Nominal heating capacity COP Low heating capacity COP HSPF Btu/h 95 °F Btu/h 47 °F Btu/h 17 °F 2MXS18GVJU 3059249 Non Ducted Indoor Unit 18,000 12.60 19.50 22,000 3.40 13,500 2.70 9.20 3059247 ...
Page 25 - Priority Room Setting; Priority; Priority setting with inverter Powerful operation
The indoor unit for which Priority Room Setting is applied takes priority in the following cases: n Operation Mode Priority . The operation mode of the indoor unit which is set for priority room setting takes priority. The user can select a different operation mode from other rooms. However, these u...
Page 26 - Reduced Installation Space; For 3 split-type units
Reduced Installation Space For 3 split-type units Crowded and space-consuming Neat and simple Three outdoor units Wall facing one side Walls facing three sides One outdoor unit Wall facing two sides Daikin’s range of multi-split systems is ideal for installations where space for outdoor units is lim...
Page 28 - FCQ 4-Way Ceiling Mounted Cassette Units
RZQ18PVJU RZQ24PVJURZQ30PVJU 1-3/16 (30mm) MIN 2 (51mm) MIN 2 (51mm) MIN 47-1/4 (1200mm) MAINTENANCE) (SPACE FOR REAR REQUIRED SPACE RIGHT PERFORMAN CE) (SP A CE FOR THE MARK ( ) SHOWS PIPING DIRECTION LEFT MAINTENANCE) (SPACE FOR H H 59" or more 59" or more 59" or more 59" or more A...
Page 30 - RXS Outdoor Unit Accessories; FCQ Indoor Unit Accessories; SkyAir Controllers and Accessories
Individual Zone Controllers Model Navigation Wired R/C BRC1E71 Wireless R/C BRC7C812 BRC7E83 Wired Remote Controller BRC944B2 Wireless Remote Controller ARC452A6 (use with FTXS) No. of Units Controllable 1 Group/16 Units 1 Group/16 Units 1 Unit 1 Unit User friendly Backlit LCD Display ü °F/°C Select...
Page 31 - VRV; Product Line
We also offer... VRV ® Product Line Available in 3 and 4-Ton, 208-230V/60Hz/1ph Individual zone control Can operate up to 6 or 8 fan coil units Energy efficient for light commercial and residential applications Innovative space-saving design Reliability Outstanding warranties For more ...